34 research outputs found

    Gaze Behavior in One-Handed Catching and Its Relation with Interceptive Performance: What the Eyes Can't Tell

    Get PDF
    In ball sports, it is usually acknowledged that expert athletes track the ball more accurately than novices. However, there is also evidence that keeping the eyes on the ball is not always necessary for interception. Here we aimed at gaining new insights on the extent to which ocular pursuit performance is related to catching performance. To this end, we analyzed eye and head movements of nine subjects catching a ball projected by an actuated launching apparatus. Four different ball flight durations and two different ball arrival heights were tested and the quality of ocular pursuit was characterized by means of several timing and accuracy parameters. Catching performance differed across subjects and depended on ball flight characteristics. All subjects showed a similar sequence of eye movement events and a similar modulation of the timing of these events in relation to the characteristics of the ball trajectory. On a trial-by-trial basis there was a significant relationship only between pursuit duration and catching performance, confirming that keeping the eyes on the ball longer increases catching success probability. Ocular pursuit parameters values and their dependence on flight conditions as well as the eye and head contributions to gaze shift differed across subjects. However, the observed average individual ocular behavior and the eye-head coordination patterns were not directly related to the individual catching performance. These results suggest that several oculomotor strategies may be used to gather information on ball motion, and that factors unrelated to eye movements may underlie the observed differences in interceptive performance

    Robot-mediated therapy for paretic upper limb of chronic patients following neurological injury

    Get PDF
    Objective: To evaluate the effectiveness of robot-mediated therapy targeted at the motor recovery of the upper limb in chronic patients following neurological injury

    Upper Limb Spasticity Reduction Following Active Training: A Robot-Mediated Study In Patients With Chronic Hemiparesis

    Get PDF
    sion of the arm. A 3-month follow-up was performed. Results: Statistically significant improvements were found in both groups after treatment. Some differences were found in elbow motor improvement between the 2 groups. Conclusion: Comparison between groups confirms that active movement training does not result in increased hypertonia, but results in spasticity reduction in antagonist muscles by activating the reciprocal inhibition mechanism. Furthermore, robot-mediated therapy contributes to a decrease in motor impairment of the upper limbs in subjects with chronic hemiparesis, resulting in a reduction in shoulder pain

    Catching a Ball at the Right Time and Place: Individual Factors Matter

    Get PDF
    Intercepting a moving object requires accurate spatio-temporal control. Several studies have investigated how the CNS copes with such a challenging task, focusing on the nature of the information used to extract target motion parameters and on the identification of general control strategies. In the present study we provide evidence that the right time and place of the collision is not univocally specified by the CNS for a given target motion; instead, different but equally successful solutions can be adopted by different subjects when task constraints are loose. We characterized arm kinematics of fourteen subjects and performed a detailed analysis on a subset of six subjects who showed comparable success rates when asked to catch a flying ball in three dimensional space. Balls were projected by an actuated launching apparatus in order to obtain different arrival flight time and height conditions. Inter-individual variability was observed in several kinematic parameters, such as wrist trajectory, wrist velocity profile, timing and spatial distribution of the impact point, upper limb posture, trunk motion, and submovement decomposition. Individual idiosyncratic behaviors were consistent across different ball flight time conditions and across two experimental sessions carried out at one year distance. These results highlight the importance of a systematic characterization of individual factors in the study of interceptive tasks

    Wrist-Worn Wearables Based on Force Myography: On the Significance of User Anthropometry

    Get PDF
    Background Force myography (FMG) is a non-invasive technology used to track functional movements and hand gestures by sensing volumetric changes in the limbs caused by muscle contraction. Force transmission through tissue implies that differences in tissue mechanics and/or architecture might impact FMG signal acquisition and the accuracy of gesture classifier models. The aim of this study is to identify if and how user anthropometry affects the quality of FMG signal acquisition and the performance of machine learning models trained to classify different hand and wrist gestures based on that data. Methods Wrist and forearm anthropometric measures were collected from a total of 21 volunteers aged between 22 and 82 years old. Participants performed a set of tasks while wearing a custom-designed FMG band. Primary outcome measure was the Spearman’s correlation coefficient (R) between the anthropometric measures and FMG signal quality/ML model performance. Results Results demonstrated moderate (0.3 ≤|R| < 0.67) and strong (0.67 ≤ |R|) relationships for ratio of skinfold thickness to forearm circumference, grip strength and ratio of wrist to forearm circumference. These anthropometric features contributed to 23–30% of the variability in FMG signal acquisition and as much as 50% of the variability in classification accuracy for single gestures. Conclusions Increased grip strength, larger forearm girth, and smaller skinfold-to-forearm circumference ratio improve signal quality and gesture classification accuracy

    A novel method for measuring gaze orientation in space in unrestrained head conditions

    Get PDF
    Investigation of eye movement strategies often requires the measurement of gaze orientation without restraining the head. However, most commercial eye-trackers have low tolerance for head movements. Here we present a novel geometry-based method to estimate gaze orientation in space in unrestricted head conditions. The method combines the measurement of eye-in-head orientation-provided by a head-mounted video-based eye-tracker-and head-in-space position and orientation-provided by a motion capture system. The method does not rely on specific assumptions on the configuration of the eye-tracker camera with respect to the eye and uses a central projection to estimate the pupil position from the camera image, thus improving upon previously proposed geometry-based procedures. The geometrical parameters for the mapping between pupil image and gaze orientation are derived with a calibration procedure based on nonlinear constrained optimization. Additionally, the method includes a procedure to correct for possible slippages of the tracker helmet based on a geometrical representation of the pupil-to-gaze mapping. We tested and validated our method on seven subjects in the context of a one-handed catching experiment. We obtained accuracy better than 0.8° and precision better than 0.5° in the measurement of gaze orientation. Our method can be used with any video-based eye-tracking system to investigate eye movement strategies in a broad range of naturalistic experimental scenarios

    A new ball launching system with controlled flight parameters for catching experiments

    No full text
    Systematic investigations of sensorimotor control of interceptive actions in naturalistic conditions, such as catching or hitting a ball moving in three-dimensional space, requires precise control of the projectile flight parameters and of the associated visual stimuli. Such control is challenging when air drag cannot be neglected because the mapping of launch parameters into flight parameters cannot be computed analytically. We designed, calibrated, and experimentally validated an actuated launching apparatus that can control the average spatial position and flight duration of a ball at a given distance from a fixed launch location. The apparatus was constructed by mounting a ball launching machine with adjustable delivery speed on an actuated structure capable of changing the spatial orientation of the launch axis while projecting balls through a hole in a screen hiding the apparatus. The calibration procedure relied on tracking the balls with a motion capture system and on approximating the mapping of launch parameters into flight parameters by means of polynomials functions. Polynomials were also used to estimate the variability of the flight parameters. The coefficients of these polynomials were obtained using the launch and flight parameters of 660 launches with 65 different initial conditions. The relative accuracy and precision of the apparatus were larger than 98% for flight times and larger than 96% for ball heights at a distance of 6m from the screen. Such novel apparatus, by reliably and automatically controlling desired ball flight characteristics without neglecting air drag, allows for a systematic investigation of naturalistic interceptive tasks

    Grasping in One-Handed Catching in Relation to Performance

    No full text
    corecore