7 research outputs found

    Implant insertion torque value in immediate loading : a retrospective study

    Get PDF
    The aim of this study is to verify if the Insertion Torque Value (ITV) of 32 Ncm for immediate loading protocol (ILP), as indicated by literature, is still, with the advance in implant research, a real significant cut-off for long-term implant survival. In this retrospective study, data from 224 patients that during three years of clinical practice, were submitted to the insertion of 322 implants with immediate loading protocol, have been recorded, pooled and analyzed. Data were organized based on Insertion Torque Value (ITV): > 32 Ncm (CG) and 32 Ncm are still characterized by a lower crestal bone resorption, there are no statistically significant differences among the two groups for what concerning the failure rate during the 2 years of follow-up and OR. These results permit us to suppose that the cut-off of ITV >32 Ncm for immediate loading implants, could be reduced to inferior values. However further studies are necessary to indicate precise clinical guidelines

    Construction of a Removable Partial Denture (RPD): Comparison between the Analog Procedure and the Selective Laser Melting Procedure

    No full text
    A partial removable denture is a device that allows the patient to recover from a partial edentulism. This case report describes the realization of a chrome–cobalt partial removable denture by using two different realization methods: (1) analogic framework and (2) hybrid framework. This allowed us to compare the stability, retention as well as clasp quality of both the products and to highlight their respective advantages, disadvantages, and limitations

    Functional Removable Prosthetic Rehabilitation Using the Electronic Condylograph: A Case Report

    No full text
    This article describes the design of complete removable prostheses following the Slavicek philosophy, which involves the integration between condylographic data and an individual cephalometric study of the patient. The electronic condylograph is a device that records the mandibular movements made by the patient. This case report shows how condylography data are useful not only in the individual articulator setting, but also for diagnostic completion and for planning a functional prosthetic rehabilitation

    Functional Removable Prosthetic Rehabilitation Using the Electronic Condylograph: A Case Report

    No full text
    This article describes the design of complete removable prostheses following the Slavicek philosophy, which involves the integration between condylographic data and an individual cephalometric study of the patient. The electronic condylograph is a device that records the mandibular movements made by the patient. This case report shows how condylography data are useful not only in the individual articulator setting, but also for diagnostic completion and for planning a functional prosthetic rehabilitation

    Childbirth Care among SARS-CoV-2 Positive Women in Italy

    No full text
    The new coronavirus emergency spread to Italy when little was known about the infection's impact on mothers and newborns. This study aims to describe the extent to which clinical practice has protected childbirth physiology and preserved the mother-child bond during the first wave of the pandemic in Italy. A national population-based prospective cohort study was performed enrolling women with confirmed SARS-CoV-2 infection admitted for childbirth to any Italian hospital from 25 February to 31 July 2020. All cases were prospectively notified, and information on peripartum care (mother-newborn separation, skin-to-skin contact, breastfeeding, and rooming-in) and maternal and perinatal outcomes were collected in a structured form and entered in a web-based secure system. The paper describes a cohort of 525 SARS-CoV-2 positive women who gave birth. At hospital admission, 44.8% of the cohort was asymptomatic. At delivery, 51.9% of the mothers had a birth support person in the delivery room; the average caesarean section rate of 33.7% remained stable compared to the national figure. On average, 39.0% of mothers were separated from their newborns at birth, 26.6% practised skin-to-skin, 72.1% roomed in with their babies, and 79.6% of the infants received their mother's milk. The infants separated and not separated from their SARS-CoV-2 positive mothers both had good outcomes. At the beginning of the pandemic, childbirth raised awareness and concern due to limited available evidence and led to "better safe than sorry" care choices. An improvement of the peripartum care indicators was observed over time

    The first SARS-CoV-2 wave among pregnant women in Italy: results from a prospective population-based study

    No full text
    Introduction. This study aimed to estimate the incidence of SARS-CoV-2 infection among pregnant women during the first pandemic wave in Italy, and to describe COVID-19 disease characteristics and maternal and perinatal outcomes. Materials and methods. National population-based prospective cohort study collecting information on women with SARS-CoV-2 diagnosis, confirmed within 7 days from hospital admission. Results. The national SARS-CoV-2 rate was 6.04 per 1,000 births (95% CI 5.62-6.49) among pregnant women and 7.54 (95% CI 7.47-7.61) among women in reproductive age. 72.1% of the cohort developed mild COVID-19 disease without pneumonia nor need for ventilatory support. Severe disease was significantly associated with women's previous comorbidities (OR 2.55; 95% CI 0.98-6.90), obesity (OR 4.76; 95% CI 1.79-12.66) and citizenship from High Migration Pressure Countries (OR 3.43; 95% CI 1.27-9.25). Conclusions. During the first pandemic wave in Italy, the SARS-CoV-2 rate among pregnant women was lower compared to that detected among women of reproductive age, and risks of severe COVID-19 disease and adverse maternal and perinatal outcomes were rare
    corecore