2 research outputs found

    SARS-CoV-2 testing among patients and healthcare professionals in an HIV outpatient clinic in Brazil

    Get PDF
    The COVID-19 pandemic in Brazil has been marked by high infection and death rates. The immune response generated by current vaccination might be influenced by previous natural infection, and baseline estimates may help in the evaluation of vaccine-induced serological response. We evaluated previous SARS-CoV-2 testing (RT-PCR), and performed rapid diagnostic tests (RDT) and high throughput electrochemiluminescence immunoassay (ECLIA) before vaccination among people living with HIV (PLWH), users of antiretroviral prophylaxis (PrEP/PEP), and healthcare professionals in an HIV outpatient clinic (HCP-HC). RDT was positive in 25.7% (95% CI: 19-33%) overall, 31.3% (95% CI : 18-45%) among PLWH, 23.7% (95% CI : 14-34%) in PrEP/PEP users and 21.4% (95% CI : 05-28%) in HCP-HC (p=0.548). Diagnostic RT-PCR testing was very limited, even for symptomatic individuals, and whereas all HCP-HC had one test perfomed, only 35% of the patients (PREP/PEP/PLWH) were tested (p<0.0001). Adequate monitoring of post-vaccination humoral response and breakthrough infections including those in asymptomatic cases are warranted, especially in immunologically compromised individuals

    Stability of anti-HIV antibodies in serum samples stored for two to eighteen years periods

    No full text
    Introduction: The antibodies have an important role in the serodiagnosis, constituting the most widely used biomarkers to detect and confirm various diseases. Objective: To investigate the reproducibility of anti-human immunodeficiency virus (HIV) antibodies reactivity, to assess the stability of the sera samples stored at -20ºC for two to eighteen years. Method: Sera were collected in the period 1988-2004 for routine anti-HIV antibodies diagnostic testing. The remaining samples stored at -20ºC, were analyzed in this study. Serum sample stability was assessed by enzyme-linked immunosorbent assay/enzyme immunoassay (ELISA/EIA), indirect immunofluorescence assay (IFA), and Western blot (WB) for detecting anti-HIV antibodies. The previously found results (1988-2004) and those obtained in 2006 were subjected to Kappa index analysis. Result: In the period 1988-to 2004, the degree of concordance of the ELISA/EIA, IFA and WB results were considered, good (k = 0.80), regular (k = 0.35), and good (k = 0.63), respectively. Conclusion: Regarding HIV serologic test, the serum samples were stable for 18 years in ELISA/EIA and for 4 years in IFA technique, however, for the WB methodology it was not possible to determine the time of stability of the anti-HIV antibodies
    corecore