810 research outputs found

    Analysis of Indoor Radon Distribution Within a Room By Means of Computational Fluid Dynamics (CFD) Simulation

    Get PDF
    Radon gas is recognized by international organizations such as the United States Environmental Protection Agency (US-EPA) as the main contributor of radiation environmental to which human beings are exposed. Therefore, the evaluation of indoor radon concentration is a matter of public interest. The emanation and the income of the gas inside a room will generate a negative impact on the quality of the air when the place is not properly ventilated. Understanding how this gas will be distributed inside the room will allow to predict the spatial and temporal variations of radon levels and identify these parameters will provide important information that researchers can be used for calculate radiation dose exposure. Consequently, this studies can prevent a health risk for the people that live or work within the room. Currently, several researchers use the technique called Computational Fluid Dynamics (CFD) to simulate the distribution of gas radon, making use of the various commercial programs that exist in the market. In this work, three simulations were developed in rooms that have a similar geometry but different dimensions, in order to observe how the gas is distributed inside a closed space and to analyze how this distribution varies when the volume of the place is increased. The results show that as the volume of the site increases the radon is mitigated more rapidly and therefore has lower levels of concentration of this gas, as long as the level of radon emanation is kept constant

    Slow and Fast Neocortical Oscillations in the Senescence-Accelerated Mouse Model SAMP8

    Get PDF
    The senescence-accelerated mouse prone 8 (SAMP8) model is characterized by accelerated, progressive cognitive decline as well as Alzheimer's disease (AD)-like neurodegenerative changes, and resembles the etiology of multicausal, sporadic late-onset/age-related AD in humans. Our aim was to find whether these AD-like pathological features, together with the cognitive deficits present in the SAMP8 strain, are accompanied by disturbances in cortical network activity with respect to control mice (SAM resistance 1, SAMR1) and, if so, how the alterations in cortical activity progress with age. For this purpose, we characterized the extracellular spontaneous oscillatory activity in different regions of the cerebral cortex of SAMP8 and SAMR1 mice under ketamine anesthesia at 5 and 7 months of age. Under these conditions, slow oscillations and fast rhythms generated in the cortical network were recorded and different parameters of these oscillations were quantified and compared between SAMP8 and their control, SAMR1 mice. The average frequency of slow oscillations in SAMP8 mice was decreased with respect to the control mice at both studied ages. An elongation of the silent periods or Down states was behind the decreased slow oscillatory frequency while the duration of active or Up states remained stable. SAMP8 mice also presented increased cycle variability and reduced high frequency components during Down states. During Up states, the power peak in the gamma range was displaced towards lower frequencies in all the cortical areas of SAMP8 with respect to control mice suggesting that the spectral profile of SAMP8 animals is shifted towards lower frequencies. This shift is reminiscent to one of the principal hallmarks of electroencephalography (EEG) abnormalities in patients with Alzheimer's disease, and adds evidence in support of the suitability of the SAMP8 mouse as a model of this disease. Although some of the differences between SAMP8 and control mice were emphasized with age, the evolution of the studied parameters as SAMR1 mice got older indicates that the SAMR1 phenotype tends to converge with that of SAMP8 animals. To our knowledge, this is the first systematic characterization of the cortical slow and fast rhythms in the SAMP8 strain and it provides useful insights about the cellular and synaptic mechanisms underlying the reported alterations

    Analysis and characterization of neutron scattering of a Linear Accelerator (LINAC) on medical applications.

    Get PDF
    In several theoretical and experimental studies, the topic of the undesirable generation of photoneutrons in rooms where a linear accelerator (LINAC) operates has been discussed. When energies above 10 MeV are used to produce X-rays and give radiotherapy treatment to patients resulting in additional radiation to patients. Accordingly, an analysis and characterization of the neutron scattering distribution on different zones in a treatment room contributes to evaluate the radiological health risk to patients, technical and other workers involved in treatment. For the evaluation, a device developed at the PAD-IFUNAM formed by a CR-39 detector enclosed by two 3mm thick acrylic plates was employed. To avoid environmental contamination, the CR-39 and the acrylics plates are enclosed in a round plastic box. Sixteen of these devices were settled in different places inside the treatment room, where a linear accelerator is used. The results show a significant concentration of neutron scattering in areas near the head of irradiation. The recommendation will be to evaluate the neutron scattering concentration in all rooms that’s operates a LINAC in order to verify the radiological health risk and to mitigate the neutron scattering when concentration levels are to high like those in our case, in order to avoid unnecessary exposition to patients and personnel in general

    The Indoor Radon Concentration within the Tunnels of the Cholula Pyramid Through a Nuclear Tracks Methodology

    Get PDF
    Global organizations, including the World Health Organization (WHO), the Environmental Protection Agency of the United States (US-EPA) and the European Atomic Energy Community (EURATOM) recognize that radon gas as one of the main contributors to environmental radiation exposure for humans. Accordingly, a study and analysis of the indoors radon concentrate in the Cholula Pyramid contributes to understand the Radon dynamic inside of the Pyramid tunnels and to evaluate the radiological health risk to visitors, archaeologists, anthropologists and persons who spend extended periods inside the Pyramid. In this paper, the radon measurements along the Pyramid tunnels are presented. The Nuclear Track Methodology (NTM) was chosen for the measurements, using a close end-cup device developed at the Dosimetry Application Project (DAP) of the Physics Institute UNAM, following very well established protocols for the chemical etching and reading with the Counting Analysis Digital Imaging System (CADIS). The Cholula Pyramid consists of eight stages of constructions, each built in different periods of time. Cholula Pyramid is recognized as the pyramid with the largest base in the World, with 400 meters per side and 65 meters high. The tunnels of the pyramid were built in 1931 by architect Ignacio Marquina, with the aim of exploring and studying the structure. The results show an important indoor radon concentration in the measured tunnels, several times higher than levels recommended by United States Environmental Protection Agency (US-EPA). The recommendation will be to mitigate the radon concentration levels, in order to avoid unnecessary exposition to the people

    Mild Regiospecific Synthesis of 1-Alkoxy-isochromenes Catalysed by Well-Defined [Silver(I)(Pc-L)] Complexes

    Get PDF
    The synthesis of 3-substituted-1-alkoxyisochromenes starting from 2-alkynylbenzaldehydes and different alcohols is reported. The reaction is catalysed by a silver(I)complex with an original macrocyclic pyridine-containing ligand (Pc-L). The approach is characterised by absolute regioselectivity, mild reaction conditions, good to excellent reaction yields, cleanness of the reaction and reduced purification steps. The reaction mechanism is investigated by in-depth 1H NMR experiments and an aimed \u201ctrapping\u201d experiment

    Sheath parameters for non-Debye plasmas: simulations and arc damage

    Get PDF
    This paper describes the surface environment of the dense plasma arcs that damage rf accelerators, tokamaks and other high gradient structures. We simulate the dense, non-ideal plasma sheath near a metallic surface using Molecular Dynamics (MD) to evaluate sheaths in the non-Debye region for high density, low temperature plasmas. We use direct two-component MD simulations where the interactions between all electrons and ions are computed explicitly. We find that the non-Debye sheath can be extrapolated from the Debye sheath parameters with small corrections. We find that these parameters are roughly consistent with previous PIC code estimates, pointing to densities in the range 10241025m310^{24} - 10^{25}\mathrm{m}^{-3}. The high surface fields implied by these results could produce field emission that would short the sheath and cause an instability in the time evolution of the arc, and this mechanism could limit the maximum density and surface field in the arc. These results also provide a way of understanding how the "burn voltage" of an arc is generated, and the relation between self sputtering and the burn voltage, while not well understood, seems to be closely correlated. Using these results, and equating surface tension and plasma pressure, it is possible to infer a range of plasma densities and sheath potentials from SEM images of arc damage. We find that the high density plasma these results imply and the level of plasma pressure they would produce is consistent with arc damage on a scale 100 nm or less, in examples where the liquid metal would cool before this structure would be lost. We find that the sub-micron component of arc damage, the burn voltage, and fluctuations in the visible light production of arcs may be the most direct indicators of the parameters of the dense plasma arc, and the most useful diagnostics of the mechanisms limiting gradients in accelerators.Comment: 8 pages, 16 figure

    Method to Fabricate Portable Electron Source based on Nitrogen Incorporated Ultrananocrystalline Diamond (N-UNCD)

    Get PDF
    A source cold cathode field emission array (FEA) source based on ultra-nanocrystalline diamond (UNCD) field emitters. This system was constructed as an alternative for detection of obscured objects and material. Depending on the geometry of the given situation a flat-panel source can be used in tomography, radiography, or tomosynthesis. Furthermore, the unit can be used as a portable electron or X-ray scanner or an integral part of an existing detection system. UNCD field emitters show great field emission output and can be deposited over large areas as the case with carbon nanotube “forest” (CNT) cathodes. Furthermore, UNCDs have better mechanical and thermal properties as compared to CNT tips which further extend the lifetime of UNCD based FEA

    Nonlinear optical properties of Au-nanoparticles conjugated with lipoic acid in water

    Get PDF
    Gold nanoparticles were chemically conjugated with lipoic acid to control their optical properties. Z-scan and other optical techniques were used to characterize the non-linear behavior of the resulting nanostructured materials. The results show that the nonlinearity is of thermal origin, which can be controlled by the use of lipoic acid as well as other organic molecules conjugated onto metal nanoparticles. In particular, the presence of lipoic acid increases n2 and dn/dT

    Analysis of the Energy Deposit in the Air by Radiation of Alpha Particles Emitted by the Water of a Spring Through the Geant4 Software

    Get PDF
    This work presents the development of an analysis of the potential radiological risk generated by alpha particles emitted by radon-222, content in a spring water, for the population that usually swims in the place and for the people who live near this spring. This spring is located in the state of Puebla. Several measurements in the water of this place by researchers from IF-UNAM showed that it contains an average radon concentration level of 70 Bq/m3. To evaluate this radiological risk, it has been developed a computational simulation to know the area and the height where the alpha particles deposit their energy to the medium, as well as the amount of energy that they transfer. This simulation was developed in the Geant4 scientific software and the calculations were executed in the supercomputer of the Laboratorio Nacional de Supercomputo del Sureste de Mexico of the BUAP. The results show that the energy deposit occurs within the superficial limits of the spring, between 7 and 8 meters high. This deposited is not only by the alpha particles, but also by the secondary particles that are generated by the interaction of alpha particles with the environment. Based on these results, it is confirmed that there is no radiological risk by energy deposit by alpha particles for the people
    corecore