    Evaluation of bone availability for grafts in different donor sites, through computed tomography

    Get PDF
    Objective: To quantify the bone volume that can be safely withdrawn from 3 donor sites: (1) the mandibular symphysis, (2) the oblique mandibular line and (3) the skullcap. Methodology: For the symphysis, 200 tomographic exams were evaluated by the extension of the anterior loop of mental foramen, by the nerve, by the distance of the foramens, by the distance between the vestibular cortical and the lingual plates and by the distance between the apexes, or lower anterior teeth, and the mandibular base, using the “distance” tool of the I-CAT Vision, in the panoramic and parasagittal reformations. For the oblique line, 70 TCFC exams were analyzed retrospectively in panoramic and parasagittal reformations, evaluating the thickness of the vestibular cortical and the distance between the cortical and the mandibular canal. For the cranial bone, a hexagonal donor site located in parietal area was considered. Results: The average dimensions of the bone blocks that can be safely removed from the region of the mandibular symphysis are: 32.27 mm in length, 4.87 mm in height and 4 mm in thickness, providing a volume of 628.61 mm3 available for grafting. In the oblique line, the available bone volume for grafting was 859.61 mm3. In the region of the cranial vault, multiplying the average bone thickness by the area of the hexagon, an average volume of 2,499 mm3 was obtained. Conclusions: Comparing the donor sites, the bone availability in the cranial vault is 3 times greater than in the mandibular posterior region, and at least 2 times greater than in the mandibular symphysis

    Seeding Osteoblastic Cells into a Macroporous Biodegradable CaP/PLGA Scaffold by a Centrifugal Force

    No full text
    This study aims to construct a hybrid biomaterial by seeding osteoblastic cells into a CaP/PLGA scaffold by a centrifugal force. Constructs are evaluated with respect to potential application in bone tissue engineering. Cells adher, spread, and form a layer of tissue lining the scaffold and are capable of migrating, proliferating, and producing mineralized matrix. We have demonstrated that the centrifugal force is highly efficient for constructing a hybrid biomaterial, which acts similarly to bone explants in a cell culture environment. In this way, these constructs could mimic an autogenous bone graft in clinical circumstances. Such a strategy may be useful for bone tissue engineering

    Photoelastic Analysis of the Influence of Platform Switching on Stress Distribution in Implants

    No full text
    The aim of this study was to evaluate the stress distribution of platform switching implants using a photoelastic method. Three models were constructed of the photoelastic resin PL-2, with a single implant and a screw-retained implant-supported prosthesis. These models were Model A, platform 5.0 mm/abutment 4.1 mm; Model B, platform 4.1 mm/abutment 4.1 mm; and Model C, platform 5.00 mm/abutment 5.00 mm. Axial and oblique (45 degrees) loads of 100 N were applied using a Universal Testing Machine (EMIC DL 3000). Images were photographed with a digital camera and visualized with software (AdobePhotoshop) to facilitate the qualitative analysis. The highest stress concentrations were observed at the apical third of the 3 models. With the oblique load, the highest stress concentrations were located at the implant apex, opposite the load application. Stress concentrations decreased in the cervical region of Model A (platform switching), and Models A (platform switching) and C (conventional/wide-diameter) displayed similar stress magnitudes. Finally, Model B (conventional/regular diameter) displayed the highest stress concentrations of the models tested

    Biomateriais aplicados à implantodontia

    No full text
    There are many ways in which materials and tissues can be brought into contact such that this co-existence may be compromised, and the search for biomaterials that are able to provide for the best performance in devices has been based upon the understanding of all interactions within biocompatibility phenomena. In this paper, the authors related the biomaterials properties applied in Implantology and their clinical indications.O meio pelo qual existe uma cooperação aceitável entre o desenvolvimento e sustentação de tecidos, promovida pela ação mútua de cooperação entre biomaterial e tecidos, tem sido o motivo da atenção da ciência em relação aos biomateriais por muitos anos, e a base do tema da biocompatibilidade. Existem muitas maneiras pelas quais os materiais e tecidos podem ser postos em contato, de tal forma que esta coexistência pode estar comprometida, e na busca de biomateriais, que são capazes de fornecer para o melhor desempenho em dispositivos foi baseada no entendimento de todas as interações fenômenos dentro de biocompatibilidade. Neste trabalho, os autores citam as propriedades dos biomateriais a serem utilizados em Implantodontia, como também suas indicações clínicas

    Sialolithiasis of the Submandibular Gland

    No full text
    Sialolithiasis of the salivary gland is a benign pathology that occurs most frequently in the submandibular gland because of its anatomic features. Depending on the sialolith size and calcification degree, it can be visible in radiographic examinations. Commonly, patients may experience pain and/or edema, when the ducts are obstructed. The authors report the case of sialolithiasis of the submandibular gland in a 42-year-old, female, white-skinned patient, noticed during routine dental examination. Following diagnosis confirmed by clinical and radiographic examinations, the treatment plan consisted of surgery for removal of the calcified mass. The prognosis is often good, and generally there is no recurrence

    Biomechanical and Microscopic Response of Bone to Titanium Implants in the Presence of Inorganic Grafts

    No full text
    This study evaluated the biomechanical and microscopic response of previously grafted bone to titanium implants. The lower incisors of 16 rabbits were surgically extracted, and bilateral perforations communicating with the remaining sockets were created distally. A socket/perforation defect on each mandible was chosen at random to be immediately filled with a xenogenic graft, whereas the contralateral perforation was left to heal naturally and served as a paired control. After 60 days, titanium implants were installed in the previously operated areas. After periods of 2 and 6 months, the animals were killed, and the force necessary to retrieve implants as well as the bone-implant contact (BIC) and bone mass (BM) were quantified and statistically compared by 2-way analysis of variance and Tukey`s test (alpha = .05). No significant differences in removal torque were observed, either by time or by treatment condition. Differences in BIC and BM between experimental and control groups were not statistically significant through the intervals studied (P < .05). The presence of a xenogenic graft did not influence the microscopic tissue response to titanium implants or fixation into newly formed or mature bone.FAPES

    Influence of Cusp Inclination on Stress Distribution in Implant-Supported Prostheses. A Three-Dimensional Finite Element Analysis

    No full text
    Purpose: The aim of this study was to assess the influence of cusp inclination on stress distribution in implant-supported prostheses by 3D finite element method.Materials and Methods: Three-dimensional models were created to simulate a mandibular bone section with an implant (3.75 mm diameter x 10 mm length) and crown by means of a 3D scanner and 3D CAD software. A screw-retained single crown was simulated using three cusp inclinations (10 degrees, 20 degrees, 30 degrees). The 3D models (model 10d, model 20d, and model 30d) were transferred to the finite element program NeiNastran 9.0 to generate a mesh and perform the stress analysis. An oblique load of 200 N was applied on the internal vestibular face of the metal ceramic crown.Results: The results were visualized by means of von Mises stress maps. Maximum stress concentration was located at the point of application. The implant showed higher stress values in model 30d (160.68 MPa). Cortical bone showed higher stress values in model 10d (28.23 MPa).Conclusion: Stresses on the implant and implant/abutment interface increased with increasing cusp inclination, and stresses on the cortical bone decreased with increasing cusp inclination

    Long-term rabbits bone response to titanium implants in the presence of inorganic bovine-derived graft

    No full text
    This study evaluated bone responses to titanium implants in the presence of an inorganic graft material. The bilateral mandible incisors of 24 rabbits were surgically extracted and one of the exposed sockets, chosen at random, was filled with an inorganic xenogenic bone graft (Gen-ox (R)), whereas the remaining socket was left to heal naturally and served as a control. After 60 days, titanium implants were inserted in the specific areas, and on days 0, 30, 60, and 180 after the implant insertions, six animals of each group were killed. Digital periapical radiography of implant region was obtained and vertical bone height (VBH) and bone density (BD) were evaluated by digital analysis system. In the undecalcified tissue cuts, bone-to-implant contact (BIC) and bone area (BA) within the limits of the implant threads were evaluated and compared statistically by means of two-way ANOVA and Tukey's test (rho &lt; 0.05). No significant differences were detected in VBH and BA, either between groups or between different experimental intervals. The BD was significantly higher in the experimental group than in the control group in all the intervals tested, but there were no significant differences by interval. The BIC was statistically lower in the control group on day 0; however, a significant increase was observed on days 60 and 180 (rho &lt; 0.05). The use of an inorganic xenograft prior to insertion of a titanium implant did not interfere with the course of osseointegration.FAPESP [06/1545-7]FAPES

    Finite element analysis of stress distribution in anchor teeth in surgically assisted rapid palatal expansion

    No full text
    The treatment of a transverse maxillary deficiency in skeletally mature individuals should include surgically assisted rapid palatal expansion. This study evaluated the distribution of stresses that affect the expander's anchor teeth using finite element analysis when the osteotomy is varied. Five virtual models were built and the surgically assisted rapid palatal expansion was simulated. Results showed tension on the lingual face of the teeth and alveolar bone, and compression on the buccal side of the alveolar bone. The subtotal Le Fort I osteotomy combined with intermaxillary suture osteotomy seemed to reduce the dissipation of tensions. Therefore, subtotal Le Fort I osteotomy without a step in the zygomaticomaxillary buttress, combined with intermaxillary suture osteotomy and pterygomaxillary disjunction may be the osteotomy of choice to reduce tensions on anchor teeth, which tend to move mesiobuccally (premolar) and distobuccally (molar
    corecore