193 research outputs found

    Outcomes of Naviculectomy for Severe Recurrent Clubfoot Deformity

    Get PDF
    Background: Naviculectomy was originally described for resistant congenital vertical talus deformity but was later expanded to use in rigid cavus deformity. This study reviews the operative outcomes of complete excision of the navicular for recurrent deformity in the talipes equinovarus (TEV) population. Methods: After institutional review board approval, all patients undergoing naviculectomy at a single institution were identified. Clinical, radiographic, and pedobarographic data (minimum 2 years’ follow-up) were reviewed. Results: Twelve patients (14 feet) with TEV from 1984 to 2019 were included. All feet had minimum 1 prior operative intervention on the affected foot (mean age = 4.0 years, range 0.2-14.5), with 8/14 having at least 3 prior operative procedures. Complete navicular excision with concomitant procedures was performed in all patients (mean age = 11.7 years, range 5.5-16.1). Mean clinical follow-up from naviculectomy was 5.1 years (range, 2.2-11.2). During follow-up, 6 patients required subsequent surgery, most often secondary to pain and progressive deformity. One patient underwent elective below-knee amputation of the affected extremity. Of the remaining 11 patients, 7 of 11 reported continued pain and 8 of 11 maintained adequate range of motion at the ankle at the most recent follow-up. Conclusion: Clinical follow-up demonstrated deteriorating results in a large percentage of patients. The high rate of additional procedures and continued pain in the current series suggests that even as a salvage procedure, naviculectomy may not provide adequate results for patients. Level of Evidence: Level IV, case series

    A Resolved Ring of Debris Dust around the Solar Analog HD 107146

    Get PDF
    We present resolved images of the dust continuum emission from the debris disk around the young (80-200 Myr) solar-type star HD 107146 with CARMA at λ = 1.3 mm and the CSO at λ = 350 μ. Both images show that the dust emission extends over an approximately 10" diameter region. The high-resolution (3") CARMA image further reveals that the dust is distributed in a partial ring with significant decrease in a flux inward of 97 AU. Two prominent emission peaks appear within the ring separated by ~140° in the position angle. The morphology of the dust emission is suggestive of dust captured into a mean motion resonance, which would imply the presence of a planet at an orbital radius of ~45-75 AU

    Atmospheric phase correction using CARMA-PACS: high angular resolution observations of the FU Orionis star PP 13S*

    Get PDF
    We present 0".15 resolution observations of the 227 GHz continuum emission from the circumstellar disk around the FU Orionis star PP 13S*. The data were obtained with the Combined Array for Research in Millimeter-wave Astronomy (CARMA) Paired Antenna Calibration System (C-PACS), which measures and corrects the atmospheric delay fluctuations on the longest baselines of the array in order to improve the sensitivity and angular resolution of the observations. A description of the C-PACS technique and the data reduction procedures are presented. C-PACS was applied to CARMA observations of PP 13S*, which led to a factor of 1.6 increase in the observed peak flux of the source, a 36% reduction in the noise of the image, and a 52% decrease in the measured size of the source major axis. The calibrated complex visibilities were fitted with a theoretical disk model to constrain the disk surface density. The total disk mass from the best-fit model corresponds to 0.06 M_⊙, which is larger than the median mass of a disk around a classical T Tauri star. The disk is optically thick at a wavelength of 1.3 mm for orbital radii less than 48 AU. At larger radii, the inferred surface density of the PP 13S* disk is an order of magnitude lower than that needed to develop a gravitational instability

    Primacy of effective communication and its influence on adherence to artemether-lumefantrine treatment for children under five years of age: a qualitative study.

    Get PDF
    BACKGROUND\ud \ud Prompt access to artemesinin-combination therapy (ACT) is not adequate unless the drug is taken according to treatment guidelines. Adherence to the treatment schedule is important to preserve efficacy of the drug. Although some community based studies have reported fairly high levels of adherence, data on factors influencing adherence to artemether-lumefantrine (AL) treatment schedule remain inadequate. This study was carried-out to explore the provider's instructions to caretakers, caretakers' understanding of the instructions and how that understanding was likely to influence their practice with regard to adhering to AL treatment schedule.\ud \ud METHODS\ud \ud A qualitative study was conducted in five villages in Kilosa district, Tanzania. In-depth interviews were held with providers that included prescribers and dispensers; and caretakers whose children had just received AL treatment. Information was collected on providers' instructions to caretakers regarding dose timing and how to administer AL; and caretakers' understanding of providers' instructions.\ud \ud RESULTS\ud \ud Mismatch was found on providers' instructions as regards to dose timing. Some providers' (dogmatists) instructions were based on strict hourly schedule (conventional) which was likely to lead to administering some doses in awkward hours and completing treatment several hours before the scheduled time. Other providers (pragmatists) based their instruction on the existing circumstances (contextual) which was likely to lead to delays in administering the initial dose with serious treatment outcomes. Findings suggest that, the national treatment guidelines do not provide explicit information on how to address the various scenarios found in the field. A communication gap was also noted in which some important instructions on how to administer the doses were sometimes not provided or were given with false reasons.\ud \ud CONCLUSIONS\ud \ud There is need for a review of the national malaria treatment guidelines to address local context. In the review, emphasis should be put on on-the-job training to address practical problems faced by providers in the course of their work. Further research is needed to determine the implication of completing AL treatment prior to scheduled time

    Atmospheric phase correction using the CARMA paired antennas calibration system

    Get PDF
    High angular resolution observations are essential to understand a variety of astrophysical phenomena. The resolution of millimeter wave interferometers is limited by large and rapid differential atmospheric delay fluctuations. At the Combined Array for Research in Millimeter-wave Astronomy (CARMA) we have employed a Paired Antenna Calibration System (C-PACS) for atmospheric phase compensation in the extended array configurations (up to 2 km baselines). We present a description of C-PACS and its application. We also present successful atmospheric delay corrections applied to science observations with dramatic improvements in sensitivity and angular resolution

    A controlled trial of protein enrichment of meal replacements for weight reduction with retention of lean body mass

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>While high protein diets have been shown to improve satiety and retention of lean body mass (LBM), this study was designed to determine effects of a protein-enriched meal replacement (MR) on weight loss and LBM retention by comparison to an isocaloric carbohydrate-enriched MR within customized diet plans utilizing MR to achieve high protein or standard protein intakes.</p> <p>Methods</p> <p>Single blind, placebo-controlled, randomized outpatient weight loss trial in 100 obese men and women comparing two isocaloric meal plans utilizing a standard MR to which was added supplementary protein or carbohydrate powder. MR was used twice daily (one meal, one snack). One additional meal was included in the meal plan designed to achieve individualized protein intakes of either 1) 2.2 g protein/kg of LBM per day [high protein diet (HP)] or 2) 1.1 g protein/kg LBM/day standard protein diet (SP). LBM was determined using bioelectrical impedance analysis (BIA). Body weight, body composition, and lipid profiles were measured at baseline and 12 weeks.</p> <p>Results</p> <p>Eighty-five subjects completed the study. Both HP and SP MR were well tolerated, with no adverse effects. There were no differences in weight loss at 12 weeks (-4.19 ± 0.5 kg for HP group and -3.72 ± 0.7 kg for SP group, p > 0.1). Subjects in the HP group lost significantly more fat weight than the SP group (HP = -1.65 ± 0.63 kg; SP = -0.64 ± 0.79 kg, P = 0.05) as estimated by BIA. There were no significant differences in lipids nor fasting blood glucose between groups, but within the HP group a significant decrease in cholesterol and LDL cholesterol was noted at 12 weeks. This was not seen in the SP group.</p> <p>Conclusion</p> <p>Higher protein MR within a higher protein diet resulted in similar overall weight loss as the standard protein MR plan over 12 weeks. However, there was significantly more fat loss in the HP group but no significant difference in lean body mass. In this trial, subject compliance with both the standard and protein-enriched MR strategy for weight loss may have obscured any effect of increased protein on weight loss demonstrated in prior weight loss studies using whole food diets.</p

    The structural basis of lipid scrambling and inactivation in the endoplasmic reticulum scramblase TMEM16K

    Get PDF
    Membranes in cells have defined distributions of lipids in each leaflet, controlled by lipid scramblases and flip/floppases. However, for some intracellular membranes such as the endoplasmic reticulum (ER) the scramblases have not been identified. Members of the TMEM16 family have either lipid scramblase or chloride channel activity. Although TMEM16K is widely distributed and associated with the neurological disorder autosomal recessive spinocerebellar ataxia type 10 (SCAR10), its location in cells, function and structure are largely uncharacterised. Here we show that TMEM16K is an ER-resident lipid scramblase with a requirement for short chain lipids and calcium for robust activity. Crystal structures of TMEM16K show a scramblase fold, with an open lipid transporting groove. Additional cryo-EM structures reveal extensive conformational changes from the cytoplasmic to the ER side of the membrane, giving a state with a closed lipid permeation pathway. Molecular dynamics simulations showed that the open-groove conformation is necessary for scramblase activity
    • …
    corecore