104 research outputs found

    A New Digital Preoperative Planning Method for Total Hip Arthroplasties

    Get PDF
    Preoperative templating is an important part of a THA. The ability to accurately determine magnification of the hip on the radiograph and apply identical magnification to the radiograph and template will improve accuracy of preoperative templating of THA. We designed a templating method using a new way of determining the hip magnification with a linear relationship between magnification of the hip and the reference object on top of the pubis symphysis; the relationship was determined on 50 radiographs. We then compared our method with two other templating methods: an analog method assuming an average hip magnification of 15% and a digital method determining the hip magnification with a one-to-one relationship between the reference object and the hip. All methods were reproducible. Uniform undersizing occurred when templating with the digital method based on the one-to-one relationship; the analog method best predicted the implanted prosthesis size, closely followed by our new digital templating method; the new method will be particularly applicable for preoperative THA when analog methods are replaced by digital method

    Predicting neonatal sepsis using features of heart rate variability, respiratory characteristics and ECG-derived estimates of infant motion

    Get PDF
    This study in preterm infants was designed to characterize the prognostic potential of several features of heart rate variability (HRV), respiration, and (infant) motion for the predictive monitoring of late-onset sepsis (LOS). In a neonatal intensive care setting, the cardiorespiratory waveforms of infants with blood-culture positive LOS were analyzed to characterize the prognostic potential of 22 features for discriminating control from sepsis-state, using the Naïve Bayes algorithm. Historical data of the subjects acquired from a period sufficiently before the clinical suspicion of LOS was used as control state, whereas data from the 24 h preceding the clinical suspicion of LOS were used as sepsis state (test data). The overall prognostic potential of all features was quantified at three-hourly intervals for the period corresponding to test data by calculating the area under the receiver operating characteristics curve. For the 49 infants studied, features of HRV, respiration, and movement showed characteristic changes in the hours leading up to the clinical suspicion of sepsis, namely, an increased propensity toward pathological heart rate decelerations, increased respiratory instability, and a decrease in spontaneous infant activity, i.e., lethargy. While features characterizing HRV and respiration can be used to probe the state of the autonomic nervous system, those characterizing movement probe the state of the motor system-dysregulation of both reflects an increased likelihood of sepsis. By using readily interpretable features derived from cardiorespiratory monitoring, opportunities for pre-emptively identifying and treating LOS can be developed.</p

    FlexEvent:going beyond Case-Centric Exploration and Analysis of Multivariate Event Sequences

    Get PDF
    In many domains, multivariate event sequence data is collected focused around an entity (the case). Typically, each event has multiple attributes, for example, in healthcare a patient has events such as hospitalization, medication, and surgery. In addition to the multivariate events, also the case (a specific attribute, e.g., patient) has associated multivariate data (e.g., age, gender, weight). Current work typically only visualizes one attribute per event (label) in the event sequences. As a consequence, events can only be explored from a predefined case-centric perspective. However, to find complex relations from multiple perspectives (e.g., from different case definitions, such as doctor), users also need an event- and attribute-centric perspective. In addition, support is needed to effortlessly switch between and within perspectives. To support such a rich exploration, we present FlexEvent: an exploration and analysis method that enables investigation beyond a fixed case-centric perspective. Based on an adaptation of existing visualization techniques, such as scatterplots and juxtaposed small multiples, we enable flexible switching between different perspectives to explore the multivariate event sequence data needed to answer multi-perspective hypotheses. We evaluated FlexEvent with three domain experts in two use cases with sleep disorder and neonatal ICU data that show our method facilitates experts in exploring and analyzing real-world multivariate sequence data from different perspectives

    Continuous sensing and quantification of body motion in infants:A systematic review

    Get PDF
    Abnormal body motion in infants may be associated with neurodevelopmental delay or critical illness. In contrast to continuous patient monitoring of the basic vitals, the body motion of infants is only determined by discrete periodic clinical observations of caregivers, leaving the infants unattended for observation for a longer time. One step to fill this gap is to introduce and compare different sensing technologies that are suitable for continuous infant body motion quantification. Therefore, we conducted this systematic review for infant body motion quantification based on the PRISMA method (Preferred Reporting Items for Systematic Reviews and Meta-Analyses). In this systematic review, we introduce and compare several sensing technologies with motion quantification in different clinical applications. We discuss the pros and cons of each sensing technology for motion quantification. Additionally, we highlight the clinical value and prospects of infant motion monitoring. Finally, we provide suggestions with specific needs in clinical practice, which can be referred by clinical users for their implementation. Our findings suggest that motion quantification can improve the performance of vital sign monitoring, and can provide clinical value to the diagnosis of complications in infants.</p

    Fractional anisotropy in white matter tracts of very-low-birth-weight infants

    Get PDF
    Background: Advances in neonatal intensive care have not yet reduced the high incidence of neurodevelopmental disability among very-low-birth-weight (VLBW) infants. As neurological deficits are related to white-matter injury, early detection is important. Diffusion tensor imaging (DTI) could be an excellent tool for assessment of white-matter injury. Objective: To provide DTI fractional anisotropy (FA) reference values for white-matter tracts of VLBW infants for clinical use. Materials and methods: We retrospectively analysed DTI images of 28 VLBW infants (26-32 weeks gestational age) without evidence of white-matter abnormalities on conventional MRI sequences, and normal developmental outcome (assessed at age 1-3 years). For DTI an echoplanar sequence with diffusion gradient (b = 1,000 s/mm2) applied in 25 non-collinear directions was used. We measured FA and apparent diffusion coefficient (ADC) of different white-matter tracts in the first 4 days of life. Results: A statistically significant correlation was found between gestational age and FA of the posterior limb of the internal capsule in VLBW infants (r = 0.495, P<0.01). Conclusion: Values of FA and ADC were measured in white-matter tracts of VLBW infants. FA of the pyramidal tracts measured in the first few days after birth is related to gestational age

    Monitoring the respiratory rate of preterm infants using an ultrathin film sensor embedded in the bedding: a comparative feasibility study

    Get PDF
    Objective: To determine the feasibility of unobtrusively monitoring the respiratory rate (RR) in preterm infants by using a film-like pressure sensor placed between the mattress and the bedding. Approach: The RR was simultaneously measured by processing the chest impedance (CI) and the ballistographic (BSG) signal acquired from the pressure sensor in 10 preterm infants of varying body weight. Nearly 27 h of data were analyzed from these infants while in different body positions including both spontaneously breathing infants and those receiving non-invasive respiratory support. Main results: The RR acquired from the BSG signal (RR-BSG) was significantly correlated (r = 0.74) to the RR derived from the CI (RR-CI) with narrow 95% limits of agreement (10 breaths min -1). A subanalysis of epochs most and least affected by infant movement yielded comparable results. Significance: Irrespective of body weight or infant position, unobtrusively monitoring the RR of preterm infants is feasible using film-like pressure sensors

    CheckMates, Helping Nurses Plan Ahead in the Neonatal Intensive Care Unit

    Get PDF
    Workflow in a neonatal intensive care unit (NICU) is relatively unpredictable, which makes it difficult to plan activities. Simple tasks, such as checking device statuses may be forgotten, resulting in disturbing alarms. In this paper, we will present CheckMates, ambient lighting displays, which visualize device statuses to provide nurses with more overview. We performed expert reviews to obtain insights into the different potentials of CheckMates. Additionally, we performed a simulation study to gather user experiences regarding the functioning of CheckMates and their capacity to improve planning in an NICU environment. The results showed a variety of potential benefits for increasing nurses&rsquo; overview of device statuses and their opportunities for workflow planning. Furthermore, CheckMates did not appear to be distracting
    corecore