64 research outputs found
Performance Comparison for Ballistocardiogram Peak Detection Methods
Citation: Suliman, A., Carlson, C., Ade, C. J., Warren, S., & Thompson, D. E. (2019). Performance Comparison for Ballistocardiogram Peak Detection Methods. IEEE Access, 7, 53945–53955. https://doi.org/10.1109/ACCESS.2019.2912650A number of research groups have proposed methods for ballistocardiogram (BCG) peak detection toward the identification of individual cardiac cycles. However, objective comparisons of these proposed methods are lacking. This paper, therefore, conducts a systematic and objective performance evaluation and comparison of several of these approaches. Five peak-detection methods (three replicated from the literature and two adapted from code provided by the methods' authors) are compared using data from 30 volunteers. A basic cross-correlation approach was also included as a sixth method. Two high-performing methods were identified: the method proposed by Sadek et al. and the method proposed by Brüser et al. The first achieved the highest average peak-detection rate of 94%, the lowest average false alarm rate of 0.0552 false alarms per second, and a relatively small mean absolute error between the real and detected peaks: 0.0175 seconds. The second method achieved the lowest mean absolute error of 0.0088 seconds between the real and detected peaks, an average peak-detection success rate of 89%, and 0.0766 false alarms per second. All metrics are averaged across participants
Effect of exercise-induced muscle damage on vascular function and skeletal muscle microvascular deoxygenation
Citation: Caldwell, J. T., Wardlow, G. C., Branch, P. A., Ramos, M., Black, C. D., & Ade, C. J. (2016). Effect of exercise-induced muscle damage on vascular function and skeletal muscle microvascular deoxygenation. Physiological Reports, 4(22), 12. doi:10.14814/phy2.13032This paper investigated the effects of unaccustomed eccentric exercise-induced muscle damage (EIMD) on macro-and microvascular function. We tested the hypotheses that resting local and systemic endothelial-dependent flow-mediated dilation (FMD) and microvascular reactivity would decrease, (V) over dotO(2max) would be altered, and that during ramp exercise, peripheral O-2 extraction, evaluated via near-infrared-derived spectroscopy (NIRS) derived deoxygenated hemoglobin + myoglobin ([HHb]), would be distorted following EIMD. In 13 participants, measurements were performed prior to (Pre) and 48 h after a bout of knee extensor eccentric exercise designed to elicit localized muscle damage (Post). Flow-mediated dilation and postocclusive reactive hyperemic responses measured in the superficial femoral artery served as a measurement of local vascular function relative to the damaged tissue, while the brachial artery served as an index of nonlocal, systemic, vascular function. During ramp-incremental exercise on a cycle ergometer, [HHb] and tissue saturation (TSI%) in the m. vastus lateralis were measured. Superficial femoral artery FMD significantly decreased following EIMD (pre 6.75 +/- 3.89%; post 4.01 +/- 2.90%; P 0.05). At each progressive increase in workload (i.e., 0-100% peak), the [HHb] and TOI% responses were similar pre-and 48 h post-EIMD (P > 0.05). Additionally, (V) over dotO(2max) was similar at pre-(3.0 +/- 0.67 L min(-1)) to 48 h post (2.96 +/- 0.60 L min(-1))-EIMD (P > 0.05). Results suggest that moderate eccentric muscle damage leads to impaired local, but not systemic, macrovascular dysfunction
Altered Blood Flow Response to Small Muscle Mass Exercise in Cancer Survivors Treated With Adjuvant Therapy
Citation: Didier, K. D., Ederer, A. K., Reiter, L. K., Brown, M., Hardy, R., Caldwell, J., . . . Ade, C. J. (2017). Altered Blood Flow Response to Small Muscle Mass Exercise in Cancer Survivors Treated With Adjuvant Therapy. Journal of the American Heart Association, 6(2), 9. doi:10.1161/jaha.116.004784Background-Adjuvant cancer treatments have been shown to decrease cardiac function. In addition to changes in cardiovascular risk, there are several additional functional consequences including decreases in exercise capacity and increased incidence of cancer-related fatigue. However, the effects of adjuvant cancer treatment on peripheral vascular function during exercise in cancer survivors have not been well documented. We investigated the vascular responses to exercise in cancer survivors previously treated with adjuvant cancer therapies. Methods and Results-Peripheral vascular responses were investigated in 11 cancer survivors previously treated with adjuvant cancer therapies (age 58 +/- 6 years, 34 +/- 30 months from diagnosis) and 9 healthy controls group matched for age, sex, and maximal voluntary contraction. A dynamic handgrip exercise test at 20% maximal voluntary contraction was performed with simultaneous measurements of forearm blood flow and mean arterial pressure. Forearm vascular conductance was calculated from forearm blood flow and mean arterial pressure. Left ventricular ejection time index (LVETi) was derived from the arterial pressure wave form. Forearm blood flow was attenuated in cancer therapies compared to control at 20% maximal voluntary contraction (189.8 +/- 53.8 vs 247.9 +/- 80.3 mL.min (1), respectively). Forearm vascular conductance was not different between groups at rest or during exercise. Mean arterial pressure response to exercise was attenuated in cancer therapies compared to controls (107.8 +/- 10.8 vs 119.2 +/- 16.2 mm Hg). LEVTi was lower in cancer therapies compared to controls. Conclusions-These data suggest an attenuated exercise blood flow response in cancer survivors approximate to 34 months following adjuvant cancer therapy that may be attributed to an attenuated increase in mean arterial pressure
Multimode horn antennas for far-infrared astronomy
Multi-mode horns combined with bolometric or incoherent detectors are finding application in astronomical receivers for which partially coherent operation can provide increased throughput and thus sensitivity. This is advantageous when observing faint sources, especially if diffraction limited resolution is not required, or if the horn beam is truncated by a cold stop in the optical train. We discuss how such horns can be simulated and present examples from receiver instrumentation on the Planck and SPICA space telescopes
A cryogenic rotation stage with a large clear aperture for the half-wave plates in the Spider instrument
We describe the cryogenic half-wave plate rotation mechanisms built for and
used in Spider, a polarization-sensitive balloon-borne telescope array that
observed the Cosmic Microwave Background at 95 GHz and 150 GHz during a
stratospheric balloon flight from Antarctica in January 2015. The mechanisms
operate at liquid helium temperature in flight. A three-point contact design
keeps the mechanical bearings relatively small but allows for a large (305 mm)
diameter clear aperture. A worm gear driven by a cryogenic stepper motor allows
for precise positioning and prevents undesired rotation when the motors are
depowered. A custom-built optical encoder system monitors the bearing angle to
an absolute accuracy of +/- 0.1 degrees. The system performed well in Spider
during its successful 16 day flight.Comment: 11 pages, 7 figures, Published in Review of Scientific Instruments.
v2 includes reviewer changes and longer literature revie
Modeling and characterization of the SPIDER half-wave plate
Spider is a balloon-borne array of six telescopes that will observe the
Cosmic Microwave Background. The 2624 antenna-coupled bolometers in the
instrument will make a polarization map of the CMB with approximately one-half
degree resolution at 145 GHz. Polarization modulation is achieved via a
cryogenic sapphire half-wave plate (HWP) skyward of the primary optic. We have
measured millimeter-wave transmission spectra of the sapphire at room and
cryogenic temperatures. The spectra are consistent with our physical optics
model, and the data gives excellent measurements of the indices of A-cut
sapphire. We have also taken preliminary spectra of the integrated HWP, optical
system, and detectors in the prototype Spider receiver. We calculate the
variation in response of the HWP between observing the CMB and foreground
spectra, and estimate that it should not limit the Spider constraints on
inflation
Pointing control for the SPIDER balloon-borne telescope
We present the technology and control methods developed for the pointing
system of the SPIDER experiment. SPIDER is a balloon-borne polarimeter designed
to detect the imprint of primordial gravitational waves in the polarization of
the Cosmic Microwave Background radiation. We describe the two main components
of the telescope's azimuth drive: the reaction wheel and the motorized pivot. A
13 kHz PI control loop runs on a digital signal processor, with feedback from
fibre optic rate gyroscopes. This system can control azimuthal speed with <
0.02 deg/s RMS error. To control elevation, SPIDER uses stepper-motor-driven
linear actuators to rotate the cryostat, which houses the optical instruments,
relative to the outer frame. With the velocity in each axis controlled in this
way, higher-level control loops on the onboard flight computers can implement
the pointing and scanning observation modes required for the experiment. We
have accomplished the non-trivial task of scanning a 5000 lb payload
sinusoidally in azimuth at a peak acceleration of 0.8 deg/s, and a peak
speed of 6 deg/s. We can do so while reliably achieving sub-arcminute pointing
control accuracy.Comment: 20 pages, 12 figures, Presented at SPIE Ground-based and Airborne
Telescopes V, June 23, 2014. To be published in Proceedings of SPIE Volume
914
The Second-generation z (Redshift) and Early Universe Spectrometer. I. First-light Observation of a Highly Lensed Local-ulirg Analog at High-z
We recently commissioned our new spectrometer, the second-generation z(Redshift) and Early Universe Spectrometer (ZEUS-2) on the Atacama Pathfinder Experiment telescope. ZEUS-2 is a submillimeter grating spectrometer optimized for detecting the faint and broad lines from distant galaxies that are redshifted into the telluric windows from 200 to 850 μm. It uses a focal plane array of transition-edge sensed bolometers, the first use of these arrays for astrophysical spectroscopy. ZEUS-2 promises to be an important tool for studying galaxies in the years to come because of its synergy with Atacama Large Millimeter Array and its capabilities in the short submillimeter windows that are unique in the post-Herschel era. Here, we report on our first detection of the [C II] 158 μm line with ZEUS-2. We detect the line at z ~ 1.8 from H-ATLAS J091043.1–000322 with a line flux of (6.44 ± 0.42) × 10^(–18) W m^(–2). Combined with its far-IR luminosity and a new Herschel-PACS detection of the [O I] 63 μm line, we model the line emission as coming from a photo-dissociation region with far-ultraviolet radiation field, G ~ 2 × 10^4 G_0, gas density, n ~ 1 × 10^3 cm^(–3) and size between ~0.4 and 1 kpc. On the basis of this model, we conclude that H-ATLAS J091043.1–000322 is a high-redshift analog of a local ultra-luminous IR galaxy; i.e., it is likely the site of a compact starburst caused by a major merger. Further identification of these merging systems is important for constraining galaxy formation and evolution models
The Second-Generation \u3cem\u3ez\u3c/em\u3e (Redshift) and Early Universe Spectrometer. I. First-Light Observation of a Highly Lensed Local Ulirg Analog at High-\u3cem\u3ez\u3c/em\u3e
We recently commissioned our new spectrometer, the second-generation z(Redshift) and Early Universe Spectrometer (ZEUS-2) on the Atacama Pathfinder Experiment telescope. ZEUS-2 is a submillimeter grating spectrometer optimized for detecting the faint and broad lines from distant galaxies that are redshifted into the telluric windows from 200 to 850 μm. It uses a focal plane array of transition-edge sensed bolometers, the first use of these arrays for astrophysical spectroscopy. ZEUS-2 promises to be an important tool for studying galaxies in the years to come because of its synergy with Atacama Large Millimeter Array and its capabilities in the short submillimeter windows that are unique in the post-Herschel era. Here, we report on our first detection of the [C II] 158 μm line with ZEUS-2. We detect the line at z ~ 1.8 from H-ATLAS J091043.1–000322 with a line flux of (6.44 ± 0.42) × 10–18 W m–2. Combined with its far-IR luminosity and a new Herschel-PACS detection of the [O I] 63 μm line, we model the line emission as coming from a photo-dissociation region with far-ultraviolet radiation field, G ~ 2 × 104 G 0, gas density, n ~ 1 × 103 cm–3 and size between ~0.4 and 1 kpc. On the basis of this model, we conclude that H-ATLAS J091043.1–000322 is a high-redshift analog of a local ultra-luminous IR galaxy; i.e., it is likely the site of a compact starburst caused by a major merger. Further identification of these merging systems is important for constraining galaxy formation and evolution models
- …