27 research outputs found

    COMUNICAÇÃO CIENTÍFICA: ASPECTOS DA INTUSSUSCEPÇÃO DUPLA SEM OBSTRUÇÃO DO LÚMEN INTESTINAL EM UM CÃO

    Get PDF
    Um cão macho, SRD, de oito anos de idade, foi atendido apresentando vômito crônico e emagrecimento progressivo fazia cinco meses. Foram realizados exames laboratoriais e trânsito intestinal contrastado, sem sinais de obstrução. O exame endoscópico foi inconclusivo, sendo então indicada laparotomia exploratória, que demonstrou presença de intussuscepção, que foi retirada e explorada subseqüentemente, revelando-se ser do tipo dupla. PALAVRAS-CHAVE: Intussuscepção, cão, caquexia

    Efeitos de diferentes frações inspiradas de oxigênio sobre a dinâmica respiratória em cães submetidos à infusão contínua de propofol e mantidos em ventilação espontânea

    Get PDF
    The effects of several inspired oxygen fractions (FiO2) on the respiratory dynamics in spontaneously breathing dogs submitted to continuous infusion of propofol were evaluated. Eight adult mongrel dogs were used. Each animal underwent five anesthesias, in each procedure the patient was allowed to breath a different FiO2, thereby resulting in five groups, namely: G100 (FiO2 = 1), G80 (FiO2 = 0.8), G60 (FiO2 =0.6), G40 (FiO2 = 0.4), and G20 (FiO2 = 0.21). To induce anesthesia, propofol was given until the animals allowed orotracheal intubation, followed by immediate continuous infusion of drug. The initial measurement (M0) was recorded thirty minutes after the infusion of propofol has begun. Additional recordings were performed at 15 minute intervals for 60 minutes (M15, M30, M45 and M60). Numeric data were submitted to Analysis of Variance followed by Tukey Test (p<0.05). We recorded significantly lower values of SpO2 and SaO2 at G20, whereas PaO2 varied according to the changes in oxygen. Regarding PaCO2, the mean of G100 was greater than G20 at M30. However, spontaneously breathing dogs anesthetized with propofol at the rate of 0.7mg/kg/min should not be provided with 100%, 80%, and 21% oxygen owing to the significant compromise of respiratory system.Avaliaram-se os efeitos do fornecimento de diferentes frações inspiradas de oxigênio (FiO2) sobre a dinâmica respiratória em cães submetidos a infusão contínua de propofol e mantidos em ventilação espontânea. Oito cães foram submetidos a cinco anestesias diferenciando uma da outra pela FiO2 fornecida. Formaram-se cinco grupos denominados G100 (FiO2 = 1), G80 (FiO2 = 0,8), G60 (FiO2 = 0,6), G40 (FiO2 = 0,4) e G20 (FiO2 = 0,21). Os animais foram induzidos à anestesia com propofol na dose necessária para intubação, e ato contínuo iniciou-se a infusão do fármaco e o fornecimento de oxigênio conforme a FiO2 determinada para cada grupo. As primeiras mensurações foram efetuadas 30 minutos após o início da infusão do anestésico (M0), em seguida em intervalos de 15 minutos (M15, M30, M45 e M60). Os dados numéricos obtidos foram submetidos a Análise de Variância, seguida pelo teste Tukey (p<0,05). Os valores registrados de saturação de oxihemoglobina (SpO2) e SaO2 foram significativamente menores para G20, enquanto que a pressão parcial de oxigênio no sangue arterial (PaO2) variou conforme a fração de oxigênio fornecida. Para a pressão parcial de dióxido de carbono no sangue arterial (PaCO2) foram registradas diferenças em M30, no qual G100 apresentou médias superiores a G20. Conclui-se que o fornecimento de oxigênio a 100%, 80% e 21% devem ser evitados, pois proporciona prejuízos significativos ao sistema respiratório de cães anestesiados com infusão contínua de propofol na dose de 0,7mg/kg/min sob ventilação espontânea

    Ventilação controlada a volume ou a pressão em cães anestesiados com infusão contínua de propofol e sufentanil, mantidos em cefalodeclive e submetidos a diferentes pressões positivas expiratórias finais

    No full text
    Avaliaram-se os efeitos hemodinâmicos, ventilatórios e hemogasométricos decorrentes da utilização da ventilação controlada a volume ou a pressão, com diferentes valores de pressões positivas expiratórias finais (PEEPs) em cães submetidos ao cefalodeclive. Utilizaram-se 6 animais adultos, machos ou fêmeas, os quais foram induzidos à anestesia com propofol (8 mglkg por via IV), e mantidos sob anestesia total intravenosa com propofol (0,2 rnglkg/rnin) e sufentanil (0,1 f..L9/kg/min). Formaram-se dois grupos que se diferenciaram pela modalidade ventilatória utilizada, ou seja: GO-V ventilação controlada a volume e GO-P ventilação controlada a pressão. Os animais foram mantidos na posição de Trendenlemburg a 30° e submetidos a diferentes valores de PEEP (O, 5 e 10 cmH20). Os dados de cada grupo foram submetidos a uma análise de variância, seguido pelo pós teste de Tukey-Kramer. Para a comparação entre os dois grupos, utilizou-se do teste T pareado. Para todas as análises, considerou-se P<O,OS como estatisticamente significativo. Nos cães ventilados com pressão controlada foi observado variação no Vt, Ppico, Pplat, Vd alv , IS, PAPm, PCPm, 1002 e IV02 ao longo das PEEPs. No grupo dos ventilados com volume controlado houve alteração na Ppico, Pplat, Vd alv e FC. A comparação das diferentes ventilações foi caracterizada por 'variação no Vd alv, FC, PVC, PCPm, CV02, IV02 e Te02. Concluiu-se que os níveis progressivos de PEEP promoveram mínimas alterações hemodinâmicas, ventilatórias e hemogasométricas e ambas as modalidades são igualmente eficientes na manutenção da estabilidade respiratória e cardiovascular nas condições experimentais propostas.The hemodynamic, ventilatory, and btood gases parameters were evaluated in dogs undergoing either volume-controlled or pressure-controlled ventilatioo and varying PEEPs under head-down tilt. Six mature dogs of eifher sex were used. Anesthesia was induced with propofol (8 mglkg IV), and maintained with propofol (O.2mglkg/min) and sufentanil (0.1 f.1glkglmin). Two groups were constituted with differem ventilatory methods, namely: GD-V volume-controlled ventilation, and GD-P pressurecontrolled ventilation. The animais were maintained in Trendelenburg position at 3iJD aftd underwent increasing PEEP (O, 5 and 10 cmH20). Data from each group was analised statistically through an analysis of variance, which was followed by a post-hoc Tukey-Kramer test To compare groups a paired T test was used. For aD analises, p<O.05 was considered to be significant. In the dogs that underwent pressure-controlled ventilation, significant changes were documented for Vt, Ppico, Pplat, Vd alv, IS, PAPm, PCPm. 1002. and IVÜ2. as PEEPs changed. In the dogs that underwent volumecontrolled ventilation, changes were seen in Ppico, Pplat, Vd alv and FC. When groups were compared, significant differences were detected in Vd alv, FC, PVC, PCPm, CV02, IV02 . and T e02. Increasing PEEPs were concluded to cause minimal changes in the blood gases, and in the hemodynamic and ventilatory parameters. Also, both ventilatory methods were shown to be reliable in maintaining respiratory and cardiovascular stability under the proposed experimental conditions.Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES

    Assessment of the electrocardiogram in dogs with visceral leishmaniasis

    No full text
    As myocarditis and arrhythmias have been shown to occur in both human beings and dogs with leishmaniasis, electrocardiograms of 105 dogs serologically positive for this disease were assessed for rhythm disturbances and changes in ECG waves. A few expressive alterations were seen, including sinus arrest, right bundle branch block, and atrial premature beats in 14.3%, 4.8%, and 4.8% of the studied subjects, respectively. Also, the analysis of ECG waves showed changes suggestive of left atrium and ventricle enlargements, and myocardial hypoxia in some animals. Although cardiac compromise has been previously reported in dogs with leishmaniasis, only a small subset of dogs showed any alteration in the electrocardiogram, which cannot support the occurrence of myocarditis in this investigation

    Influence of body position on the measurement of electrocardiographic waves in healthy dogs

    No full text
    ABSTRACT: The agreement between the electrocardiographic waves measured from tracings recorded in right lateral recumbency and several other unusual body positions was assessed. Electrocardiograms were recorded in 160 healthy dogs in right lateral, left lateral, dorsal and sternal recumbencies, as well as in standing position. Considering the right lateral recordings as the gold standard, the lowest biases for the majority of ECG parameters were calculated from left lateral recordings, whereas the highest biases were documented from dorsal and standing positions. For the mean electrical axis, the dorsal recumbency produced the lowest bias, while the greatest one was identified in sternal position. An analysis of variance indicated differences when the means of P wave duration and amplitude, duration of QRS and QT, and mean electrical axis obtained in unusual positions were compared with right lateral. In conclusion, left lateral recumbency produced the most similar measurements as compared to right lateral, but the wide limits of agreement preclude the use and interpretation of these positions interchangeably

    Eletrocardiografia em cães anestesiados com cetamina-s ou cetamina

    No full text
    A cetamina, fármaco derivado da fenciclidina, há muito é usada na anestesia veterinária, sendo que o seu isômero (+), a cetamina S, recém-lançada no mercado, tem tido emprego principalmente na anestesia humana. em vista disso, objetivou-se, com este experimento avaliar comparativamente, as possíveis alterações eletrocardiográficas em cães anestesiados com cetamina S ou cetamina e avaliar as freqüências respiratória e cardíaca, saturação de oxihemoglobina e pressão arterial. Para tanto, foram utilizados 10 cães adultos, machos e fêmeas, sem raça definida e hígidos. Os animais foram distribuídos em dois grupos (G1 e G2) de igual número. Ao G1 administrou-se, por via intramuscular, cetamina S na dose de 20mg/kg, e ao G2, cetamina na mesma dose e via de administração empregados no G1. As observações das variáveis tiveram início imediatamente antes da aplicação dos fármacos (M1) e a cada 10 minutos (M2, M3 e M4, respectivamente). Os dados numéricos foram submetidos ao teste de Tukey, para análises repetidas no grupo, a fim de verificar significado estatístico ou não entre as médias, nos vários momentos, sendo considerado o nível de significância de 5% (p<0,05). Os resultados apresentados foram elevação da freqüência cardíaca com o uso de ambos os fármacos, discretas alterações na pressão arterial, nenhuma variação da SpO2 e impossibilidade de identificar alterações eletrocardiográficas de importância clínica entre os grupos estudados. Assim, pode-se admitir como hipótese conclusiva que as cetaminas S e racêmica apresentam efeitos similares na condutividade elétrica do miocárdio.Ketamine is a drug derived of the phenciclidine and has been used in veterinary anaesthesia for a long time. Its (+) isomers, s-ketamine, was recently introduced in the clinical practice and has been used mainly in human anaesthesia. So, this experiment was performed to evaluate comparatively possible electrocardiographic changes in dogs anesthetized with S-ketamine or ketamine and also evaluate heart rate, respiratory rate, oxihemoglobine saturation and arterial pressure. Ten adult male and female dogs were used in this study. All dogs were healthy and mix breed. The animals were divided in two equal number groups (G1 and G2). The G1 received 20mg/kg of S-ketamine intra-muscularly and G2 received the same dose of ketamine with the injection protocol. The electrocardiographic changes started immediately before the drug administration (M1) and were repeated every 10 minutes (M2, M3 and M4, respectively). The numeric data were submitted to Tukey test for analysis of the repetitions in the group to verify if the averages were statistically significant or not in the several moments with significant value of 5% (p<0.05). The presented results were heart rate elevation with both drugs, mild arterial pressure changes could also be observed. No changes in the SpO2 were detected and no electrocardiographic changes with clinic importance could be identified. Consequently it is possible to assume as a conclusive hypotheses that S-ketamine and ketamine have similar effects over the miocardium electrical conductivity.Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP
    corecore