40 research outputs found

    Provocative Tests for Myocardial Ischemia in Patients with Implantable Electronic Cardiac Devices

    Get PDF
    Objective: Review the current literature in search of better knowledge about the use of implantable devices in patients who are investigating ischemic heart disease, and evaluate the possibility of its systematic use. Methods: Non-systematic literature review with exams and studies already published to date. Results: Risk stratification using implantable cardiac devices, associated with or as a substitute for the use of medication or physical stress, seems to be very safe, effective and highly reliable when compared to the methods traditionally established. Conclusion: Patients with implantable cardiac electronic devices constitute a specific challenging population, while research on ischemia is limited by secondary low/bay perfusion changes that result from the interaction of the device with the heart. These changes must be previously known, expected and interpreted with great care in order to reduce the number of false positives

    Provocative Tests for Myocardial Ischemia in Patients with Implantable Electronic Cardiac Devices

    Get PDF
    Objective: Review the current literature in search of better knowledge about the use of implantable devices in patients who are investigating ischemic heart disease, and evaluate the possibility of its systematic use. Methods: Non-systematic literature review with exams and studies already published to date. Results: Risk stratification using implantable cardiac devices, associated with or as a substitute for the use of medication or physical stress, seems to be very safe, effective and highly reliable when compared to the methods traditionally established. Conclusion: Patients with implantable cardiac electronic devices constitute a specific challenging population, while research on ischemia is limited by secondary low/bay perfusion changes that result from the interaction of the device with the heart. These changes must be previously known, expected and interpreted with great care in order to reduce the number of false positives

    Disfuncao endotelial em pacientes submetidos a terapia com nitroglicerina e a intervencao coronaria percutanea

    No full text
    Introdução: A terapia com nitroglicerina está associada a modificações bioquímicas na vasculatura que podem levar à alterações na função endotelial. De modo análogo, as intervenções coronárias percutâneas causam intensa lesão mecânica na parede vascular que pode determinar disfunção endotelial. Objetivos: Avaliar a resposta vasomotora ao vasodilatador dependente do endotélio, acetilcolina, em artérias coronárias de pacientes submetidos a terapia com nitroglicerina e de pacientes previamente submetidos a uma intervenção coronária percutânea. Métodos: Quinze pacientes foram randomizados para receber 0,6 mg/hora de nitroglicerina transdérmica contínua (n = 8), ou para um grupo controle (n = 7), por cinco dias. Na manhã do quinto dia, angiografia quantitativa foi realizada, avaliando a resposta da artéria descendente anterior à infusão intracoronária de acetilcolina (concentração máxima 10-4 molar). O adesivo transdérmico foi, então, removido dos pacientes do grupo nitroglicerina e, três horas após, os procedimentos foram repetidos. Para investigar a função endotelial após intervenções coronárias percutâneas, foram estudados 39 pacientes submetidos a uma intervenção coronária para uma estenose na attéria descendente anterior pelo menos 6 meses antes. Doze pacientes haviam sido tratados com stents, 15 com angioplastia por cateter balão e 12 com aterectomia direcionada. As respostas da artéria descendente anterior (intervida) e da artéria circuní1exa (não intervida), à infusão de acetilcolina foram avaliadas por angiografia quantitativa. Resultados: Nos dois estudos os grupos possuíam características angiográficas e fatores de risco para disfunção endotelial similares. No estudo dos efeitos da nitroglicerina, em vigência de tratamento, o grupo nitroglicerina apresentou maior constrição coronária em resposta à acetilcolina do que o grupo controle (-19,6 + 4,2% versus -3,8 + 3,0%; P = 0,01). Três horas após a remoção do adesivo transdérmíco, o grupo nitroglicerina continuou a apresentar maior vasoconstrição em resposta à acetilcolina, quando comparado ao grupo controle ( -24,1 + 5,9% versus -1,8 + 4,8%; P < 0,01). Quando as respostas à acetilcolina nos estudos da manhã e da tarde foram comparadas, o aumento na constrição coronária observado no grupo nitroglicerina foi maior que a modificação observada nos pacientes do grupo controle (P < 0,05). No estudo dos efeitos de intervenções coronárias, a artéria descendente anterior desenvolveu constrição significativamente maior (P = 0,02) em pacientes que previamente haviam recebido stents (21,8 + 4,3%), do que pacientes tratados angioplastia por cateter balão (9,5 + 2,8%) ou com aterectomia direcionada (9,1 + 3,6%). Em contraste, a infusão de acetilcolína resultou em leve constrição da circunflexa, similar entre os três grupos (P = 0,47). Análise de regressão múltipla identificou o implante prévio de stent como único preditor de maior constrição da descendente anterior (P = 0,008). Conclusões: A terapia com nitroglicerina causa respostas vasomotoras coronárias anormais à adminis!Tação do vasodilatador dependente do endotélio, acetitcolina. Esta resposta vasoconstritora é persistente por até três horas após a retirada da nitroglicerina. Estes achados têm implicações com respeito ao desenvolvimento de tolerância a nitratos e ao potencial para eventos adversos durante a retirada de nitroglicerina. Entre pacientes que foram submetidos a uma intervenção coronária percutânea, foi observada disfunção endotelial mais grave após o implante de stents do que após uma angioplastia por cateter balão ou aterectomia direcionada. Estes achados podem ter implicações com respeito à progressão de aterosclerose em artérias coronárias submetidas a intervenções percutâneas, especialmente implante de stents.Background. Nitroglycerin tberapy is associated with specific biochemical changes in the vasculature that may lead to an increased vascular sensitivity to vasoconstrictors. Catheter-based coronary interventions are associated with extensive arterial wall injury that appears to be associated with a cbronicatly abnormal endothelial function. Objectives: 1) To investiga te whether therapy with nitroglycerin would lead to abnormal coronary artery responses to the endothelium-dependent vasodilator acetylcholine. 2) To assess tbe endotelial-dependent vasomotor function in nonrestenotic coronary arteries more than 6 months following stent implantation, balloon angioplasty, and directional atherectomy. Metbods: Fifteen patients were randomized to continuous transdermal nitroglycerin, 0.6 mg/hour (n = 8), or no therapy (n = 7), for 5 days prior to a diagnostic catheterization. Patients had similar risk factors for endothelial dysfunction. Quantitative angiography was performed in the morning to measure the mean luminal diameter of the left anterior descending (LAD) in response to intracoronary acetylcholine (peak concentration, 10-4 molar). The transdermal preparation was removed from the nitroglycerin group and 3 hours 1ater experimental procedures were repeated. Thirty~nine patients, who were treated at least 6 months earlier with a coronary intervention for isolated prox.imal LAD stenosis, with no evidence of restenosis, were included in the study of the effects o f coronary interventions on endotelial vasomotor function. Twelve patients had been stented, 15 had been treated with balloon angioplasty, and 12 had undergone directional atherectomy. The change in diameter of the intervened LAD, and the unintervened circumflex coronary artery, in response to intracoronary ac~tylcholine were assessed by quantitative angiography. Results: In both studies the groups had similar angiographic characteristics and risk factors for endothelial dysfunctíon. In the nitroglycerin study, in the morning, th.e nítroglycerin group experíenced greater coronary constriction in response to acetylcholine infusion than those not receiving nitroglycerin (-19 .6 ± 4.2% versus -3.8 ± 3.0%~ P = 0.01). Three hours later, the nitroglycerin group continued to display greater constriction to acetylcholine (-24.1 ± 5.9%) as compared to the nonnitroglycerin group (-1.8 ± 4.8%; P < 0.01). When monúng and aftemoon responses to acetylcholine were compared, the increase in coronary constriction in the nitroglycerin group was greater than the change observed in the non-nítroglycerin group (P < 0.05). In the st11dy of the effects of coronary interventions on endotelial vasomotor function, the LAD constricted significantly more (P = 0.02) in previously stented patients (21.8 + 4.3%), as compared to patíents previously treated with balloon angioplasty (9.5 + 2.8%) or with directional atherectorny (9.1 + 3.6%). In contrast, acetylcholine infusion resulted in mild constriction in the circumtlex coronary artery which was similar in the three groups (P = 0.47). By multiple regression analysis, previous implant of a stent was the only significant predictor of LAD constriction (P = 0.008). Conclusions: Therapy with nitroglycerin causes abnormal coronary vasomotor responses to the endothelíum-dependent vasodilator acetylcholíne, which were persistent for up to 3 hours after nitroglycerin discontinuation. This nitrate associated vasomotor dysf'tmction has implications with respect to the development of nitrate tolerance and the potential for adverse events during nitrate withdrawal. More severe endothelial dysfunction was observed long term after stenting as compareci to balloon angioplasty or directional atherectomy. These findings may have implications with respect to the progression of atherosclerosis in coronary arteries subjected to pcicutaneous interventions

    Reestenose pós-angioplastia : modelo experimental de angioplastia em carótida de suínos e estudo da ação do pentosam polisulfato no fenômeno da reestenose

    No full text
    Nos últimos anos, a angioplastia coronariana vem assumindo um papel definido no manejo da cardiopatia isquêmica. Apesar da alta taxa de sucesso primário, reestenose ocorre em 30 a 40% dos casos, sendo a principal limitação do método. A fisiopatologia da reestenose e as estratégias para sua prevenção têm sido estudadas através de modelos animais, especialmente em suínos, que se assemelham ao homem na morfologia e fisiologia cardiovascular e na susceptibilidade à aterosclerose. Neste modelo, os resultados da angioplastia têm sido consistentes com os achados em artérias coronárias humanas. Até o presente, nenhuma intervenção farmacológica obteve redução clinicamente significante na incidência da reestenose. Dentre as várias abordagens terapêuticas, parece de interesse a possibilidade de inibir a proliferação de células musculares lisas através do bloqueio de fatores de crescimento determinantes da hiperplasia intimai. O Pentosam polisulfato (PPS) é um polissacarídeo semi-sintético com propriedades semelhantes à heparina, o qual reduz a proliferação de células musculares em cultura, por inibição do fator de crescimento de fibroblastos básico (b-FGF). Utilizado clinicamente na profilaxia da trombose venosa profunda em países europeus, exibe tolerabilidade similar à heparina. Entretanto, não há estudos in vivo avaliando o seu efeito na proliferação da célula muscular lisa arterial. Nesta dissertação o autor buscou adaptar um modelo experimental de angioplastia em carótida de suínos capaz de induzir resposta hiperplásica da íntima, permitindo quantificar a formação da neo-íntirna e a resposta à intervenções farmacológicas, dispensando o uso de equipamento radiológico. Após, foi testada a hipótese de que o PPS pudesse modular a resposta proliferativa da célula muscular lisa neste modelo experimental. , Inicialmente, oito suínos foram utilizados na caracterização das distintas fases do experimento. Após, em doze suínos de raça cruzada, pesando entre 20 e 35 Kg, mantidos sob anestesia, a artéria carótida comum esquerda foi dissecada em sua porção cranial e o cateter-balão foi introduzido em direção à aorta e inflado até 6atm, durante 60s, por 3 vezes, com intervalos de 60s. O diâmetro da balão foi de 8mm, ou seja, 1,5 vezes superior ao da artéria em suínos deste porte. Os animais foram randomizados para receber 50mg de PPS subcutâneo, a cada 12 horas, por 30 dias, ou para serem mantidos sob cuidado usual. Os mesmos foram mantidos em cativeiro, com dieta normal e, após 4 semanas, reintervidos para excisão do segmento dilatado. As artérias foram então removidas, perfundidas e fixadas sob pressão para análise histopatológica. As imagens histológicas foram digitalizadas para posterior planimetria computadorizada das áreas da luz arterial, neo­ íntima e camada muscular. As artérias carótidas esquerdas de três animais adicionais foram utilizadas como controle para a análise histológica semiquantitativa. Observou-se reação vascular à injúria, de variada intensidade, em todas as artéria angioplastadas. A histologia convencional sugeriu maior reatividade à injúria na camada média dos animais que receberan1 o PPS, com maior deposição de matriz extracelular, perda da individualização das lâminas elásticas intermediárias e desorganização da estrutura de fibras musculares. Quanto à espessura da neo-íntima, a análise morfométrica das imagens histológicas digitalizadas não demonstrou diferença estatistica.I]lente significante entre os grupos PPS ou controle (1,19mm2 ±1,48 vs. 0,8mm2 ±0,57). Entretanto, o grupo PPS apresentou significativamente menor área luminal (0,85mm2 ±0,53 vs. 8,33mm 2 ±7,00), menor área delimitada pela lâmina elástica interna (2,05mm2 ±1,22 vs. 9,13mm 2 ±6,54 ) e maior espessamento da média, quando aferido pelo percentual da área total da artéria ocupada por esta camada (85,0% ±8,0 vs. 59,6% ±14,4). Não foram identificados efeitos hematológicos atribuíveis à droga. Em conclusão, o modelo experimental de angioplastia em carótida de suínos, através de dissecção da artéria, foi capaz de induzir formação de neo-íntima, sendo uma opção viável para estudo a reação vascular à injúria em nosso meio. O tratamento com PPS, no esquema posológico utilizado neste experimento, não foi associado a inibição dahiperplasia da í ntima subsequente à injúria por balão na carótida de suínos. Ao contrário do esperado, os animais tratados com PPS apresentaram menor área l uminal e acentuação da reação da camada média. As implicações destes achados devem ser objeto de estudos posteriores

    Reestenose pós-angioplastia : modelo experimental de angioplastia em carótida de suínos e estudo da ação do pentosam polisulfato no fenômeno da reestenose

    No full text
    Nos últimos anos, a angioplastia coronariana vem assumindo um papel definido no manejo da cardiopatia isquêmica. Apesar da alta taxa de sucesso primário, reestenose ocorre em 30 a 40% dos casos, sendo a principal limitação do método. A fisiopatologia da reestenose e as estratégias para sua prevenção têm sido estudadas através de modelos animais, especialmente em suínos, que se assemelham ao homem na morfologia e fisiologia cardiovascular e na susceptibilidade à aterosclerose. Neste modelo, os resultados da angioplastia têm sido consistentes com os achados em artérias coronárias humanas. Até o presente, nenhuma intervenção farmacológica obteve redução clinicamente significante na incidência da reestenose. Dentre as várias abordagens terapêuticas, parece de interesse a possibilidade de inibir a proliferação de células musculares lisas através do bloqueio de fatores de crescimento determinantes da hiperplasia intimai. O Pentosam polisulfato (PPS) é um polissacarídeo semi-sintético com propriedades semelhantes à heparina, o qual reduz a proliferação de células musculares em cultura, por inibição do fator de crescimento de fibroblastos básico (b-FGF). Utilizado clinicamente na profilaxia da trombose venosa profunda em países europeus, exibe tolerabilidade similar à heparina. Entretanto, não há estudos in vivo avaliando o seu efeito na proliferação da célula muscular lisa arterial. Nesta dissertação o autor buscou adaptar um modelo experimental de angioplastia em carótida de suínos capaz de induzir resposta hiperplásica da íntima, permitindo quantificar a formação da neo-íntirna e a resposta à intervenções farmacológicas, dispensando o uso de equipamento radiológico. Após, foi testada a hipótese de que o PPS pudesse modular a resposta proliferativa da célula muscular lisa neste modelo experimental. , Inicialmente, oito suínos foram utilizados na caracterização das distintas fases do experimento. Após, em doze suínos de raça cruzada, pesando entre 20 e 35 Kg, mantidos sob anestesia, a artéria carótida comum esquerda foi dissecada em sua porção cranial e o cateter-balão foi introduzido em direção à aorta e inflado até 6atm, durante 60s, por 3 vezes, com intervalos de 60s. O diâmetro da balão foi de 8mm, ou seja, 1,5 vezes superior ao da artéria em suínos deste porte. Os animais foram randomizados para receber 50mg de PPS subcutâneo, a cada 12 horas, por 30 dias, ou para serem mantidos sob cuidado usual. Os mesmos foram mantidos em cativeiro, com dieta normal e, após 4 semanas, reintervidos para excisão do segmento dilatado. As artérias foram então removidas, perfundidas e fixadas sob pressão para análise histopatológica. As imagens histológicas foram digitalizadas para posterior planimetria computadorizada das áreas da luz arterial, neo­ íntima e camada muscular. As artérias carótidas esquerdas de três animais adicionais foram utilizadas como controle para a análise histológica semiquantitativa. Observou-se reação vascular à injúria, de variada intensidade, em todas as artéria angioplastadas. A histologia convencional sugeriu maior reatividade à injúria na camada média dos animais que receberan1 o PPS, com maior deposição de matriz extracelular, perda da individualização das lâminas elásticas intermediárias e desorganização da estrutura de fibras musculares. Quanto à espessura da neo-íntima, a análise morfométrica das imagens histológicas digitalizadas não demonstrou diferença estatistica.I]lente significante entre os grupos PPS ou controle (1,19mm2 ±1,48 vs. 0,8mm2 ±0,57). Entretanto, o grupo PPS apresentou significativamente menor área luminal (0,85mm2 ±0,53 vs. 8,33mm 2 ±7,00), menor área delimitada pela lâmina elástica interna (2,05mm2 ±1,22 vs. 9,13mm 2 ±6,54 ) e maior espessamento da média, quando aferido pelo percentual da área total da artéria ocupada por esta camada (85,0% ±8,0 vs. 59,6% ±14,4). Não foram identificados efeitos hematológicos atribuíveis à droga. Em conclusão, o modelo experimental de angioplastia em carótida de suínos, através de dissecção da artéria, foi capaz de induzir formação de neo-íntima, sendo uma opção viável para estudo a reação vascular à injúria em nosso meio. O tratamento com PPS, no esquema posológico utilizado neste experimento, não foi associado a inibição dahiperplasia da í ntima subsequente à injúria por balão na carótida de suínos. Ao contrário do esperado, os animais tratados com PPS apresentaram menor área l uminal e acentuação da reação da camada média. As implicações destes achados devem ser objeto de estudos posteriores
    corecore