A luminosity monitor for the A4 parity violation experiment at MAMI
A water Cherenkov luminosity monitor system with associated electronics has
been developed for the A4 parity violation experiment at MAMI. The detector
system measures the luminosity of the hydrogen target hit by the MAMI electron
beam and monitors the stability of the liquid hydrogen target. Both is required
for the precise study of the count rate asymmetries in the scattering of
longitudinally polarized electrons on unpolarized protons. Any helicity
correlated fluctuation of the target density leads to false asymmetries. The
performance of the luminosity monitor, investigated in about 2000 hours with
electron beam, and the results of its application in the A4 experiment are
presented.Comment: 22 pages, 12 figures, submitted to NIM
Utility of pathologist panels for achieving consensus in NASH histologic scoring in clinical trials: Data from a phase 3 study
Copyright \ua9 2023 The Author(s). Published by Wolters Kluwer Health, Inc. on behalf of the American Association for the Study of Liver Diseases.Background: Liver histopathologic assessment is the accepted surrogate endpoint in NASH trials; however, the scoring of NASH Clinical Research Network (CRN) histologic parameters is limited by intraobserver and interobserver variability. We designed a consensus panel approach to minimize variability when using this scoring system. We assessed agreement between readers, estimated linear weighted kappas between 2 panels, compared them with published pairwise kappa estimates, and addressed how agreement or disagreement might impact the precision and validity of the surrogate efficacy endpoint in NASH trials. Methods: Two panels, each comprising 3 liver fellowship-trained pathologists who underwent NASH histology training, independently evaluated scanned whole slide images, scoring fibrosis, inflammation, hepatocyte ballooning, and steatosis from baseline and month 18 biopsies for 100 patients from the precirrhotic NASH study REGENERATE. The consensus score for each parameter was defined as agreement by ≥2 pathologists. If consensus was not reached, all 3 pathologists read the slide jointly to achieve a consensus score. Results: Between the 2 panels, the consensus was 97%-99% for steatosis, 91%-93% for fibrosis, 88%-92% for hepatocyte ballooning, and 84%-91% for inflammation. Linear weighted kappa scores between panels were similar to published NASH CRN values. Conclusions: A panel of 3 trained pathologists independently scoring 4 NASH CRN histology parameters produced high consensus rates. Interpanel kappa values were comparable to NASH CRN metrics, supporting the accuracy and reproducibility of this method. The high concordance for fibrosis scoring was reassuring, as fibrosis is predictive of liver-specific outcomes and all-cause mortality
Measurement of the Transverse Beam Spin Asymmetry in Elastic Electron Proton Scattering and the Inelastic Contribution to the Imaginary Part of the Two-Photon Exchange Amplitude
We report on a measurement of the asymmetry in the scattering of transversely
polarized electrons off unpolarized protons, A, at two Q values of
\qsquaredaveragedlow (GeV/c) and \qsquaredaveragedhighII (GeV/c) and a
scattering angle of . The measured transverse
asymmetries are A(Q = \qsquaredaveragedlow (GeV/c)) =
(\experimentalasymmetry alulowcorr \statisticalerrorlow
\combinedsyspolerrorlowalucor) 10 and
A(Q = \qsquaredaveragedhighII (GeV/c)) = (\experimentalasymme
tryaluhighcorr \statisticalerrorhigh
\combinedsyspolerrorhighalucor) 10. The first
errors denotes the statistical error and the second the systematic
uncertainties. A arises from the imaginary part of the two-photon
exchange amplitude and is zero in the one-photon exchange approximation. From
comparison with theoretical estimates of A we conclude that
N-intermediate states give a substantial contribution to the imaginary
part of the two-photon amplitude. The contribution from the ground state proton
to the imaginary part of the two-photon exchange can be neglected. There is no
obvious reason why this should be different for the real part of the two-photon
amplitude, which enters into the radiative corrections for the Rosenbluth
separation measurements of the electric form factor of the proton.Comment: 4 figures, submitted to PRL on Oct.
Evidence for Strange Quark Contributions to the Nucleon's Form Factors at = 0.108 (GeV/c)
We report on a measurement of the parity violating asymmetry in the elastic
scattering of polarized electrons off unpolarized protons with the A4 apparatus
at MAMI in Mainz at a four momentum transfer value of = \Qsquare
(GeV/c) and at a forward electron scattering angle of 30. The measured asymmetry is = (\Aphys
\Deltastat \Deltasyst) 10. The
expectation from the Standard Model assuming no strangeness contribution to the
vector current is A = (\Azero \DeltaAzero) 10. We
have improved the statistical accuracy by a factor of 3 as compared to our
previous measurements at a higher . We have extracted the strangeness
contribution to the electromagnetic form factors from our data to be +
\FakGMs = \GEsGMs \DeltaGEsGMs at = \Qsquare (GeV/c).
As in our previous measurement at higher momentum transfer for + 0.230
, we again find the value for + \FakGMs to be positive,
this time at an improved significance level of 2 .Comment: 4 pages, 3 figure
What do we know about dynamic glucose-enhanced (DGE) MRI and how close is it to the clinics? Horizon 2020 GLINT consortium report
Cancer is one of the most devastating diseases that the world is currently facing, accounting for 10 million deaths in 2020 (WHO). In the last two decades, advanced medical imaging has played an ever more important role in the early detection of the disease, as it increases the chances of survival and the potential for full recovery. To date, dynamic glucose-enhanced (DGE) MRI using glucose-based chemical exchange saturation transfer (glucoCEST) has demonstrated the sensitivity to detect both D-glucose and glucose analogs, such as 3-oxy-methyl-D-glucose (3OMG) uptake in tumors. As one of the recent international efforts aiming at pushing the boundaries of translation of the DGE MRI technique into clinical practice, a multidisciplinary team of eight partners came together to form the "glucoCEST Imaging of Neoplastic Tumors (GLINT)" consortium, funded by the Horizon 2020 European Commission. This paper summarizes the progress made to date both by these groups and others in increasing our knowledge of the underlying mechanisms related to this technique as well as translating it into clinical practice
Measurement of Strange Quark Contributions to the Nucleon's Form Factors at Q^2=0.230 (GeV/c)^2
We report on a measurement of the parity-violating asymmetry in the
scattering of longitudinally polarized electrons on unpolarized protons at a
of 0.230 (GeV/c)^2 and a scattering angle of \theta_e = 30^o - 40^o.
Using a large acceptance fast PbF_2 calorimeter with a solid angle of
\Delta\Omega = 0.62 sr the A4 experiment is the first parity violation
experiment to count individual scattering events. The measured asymmetry is
A_{phys} =(-5.44 +- 0.54_{stat} +- 0.27_{\rm sys}) 10^{-6}. The Standard Model
expectation assuming no strangeness contributions to the vector form factors is
. The difference is a direct measurement of the
strangeness contribution to the vector form factors of the proton. The
extracted value is G^s_E + 0.225 G^s_M = 0.039 +- 0.034 or F^s_1 + 0.130 F^s_2
= 0.032 +- 0.028.Comment: 5 pages, 3 figures, submitted to Phys. Rev. Letters on Dec 11, 200
Development and Evaluation of the Magnetic Properties of a New Manganese (II) Complex: A Potential MRI Contrast Agent
Magnetic resonance imaging (MRI) is a non-invasive powerful modern clinical technique that is extensively used for the high-resolution imaging of soft tissues. To obtain high-definition pictures of tissues or of the whole organism this technique is enhanced by the use of contrast agents. Gadolinium-based contrast agents have an excellent safety profile. However, over the last two decades, some specific concerns have surfaced. Mn(II) has different favorable physicochemical characteristics and a good toxicity profile, which makes it a good alternative to the Gd(III)-based MRI contrast agents currently used in clinics. Mn(II)-disubstituted symmetrical complexes containing dithiocarbamates ligands were prepared under a nitrogen atmosphere. The magnetic measurements on Mn complexes were carried out with MRI phantom measurements at 1.5 T with a clinical magnetic resonance. Relaxivity values, contrast, and stability were evaluated by appropriate sequences. Studies conducted to evaluate the properties of paramagnetic imaging in water using a clinical magnetic resonance showed that the contrast, produced by the complex [Mn(II)(L’)2] × 2H2O (L’ = 1.4-dioxa-8-azaspiro[4.5]decane-8-carbodithioate), is comparable to that produced by gadolinium complexes currently used in medicine as a paramagnetic contrast agent
- …