452 research outputs found

    The Number of Endothelial Progenitor Cell Colonies in the Blood Is Increased in Patients With Angiographically Significant Coronary Artery Disease

    Get PDF
    ObjectivesThe objective of this study was to determine whether the number of endothelial progenitor cells (EPCs) and circulating angiogenic cells (CACs) in peripheral blood was associated with the presence and severity of coronary artery disease (CAD) in patients undergoing coronary angiography.BackgroundPrevious studies have suggested an inverse relationship between levels of circulating EPCs/CACs and the presence of CAD or cardiovascular risk factors, whereas other studies have observed increased numbers of EPCs in the setting of acute ischemia. However, the criteria used to identify specific angiogenic cell subpopulations and methods of evaluating CAD varied in these studies. In the present study, we used rigorous criteria to identify EPCs and CACs in the blood of patients undergoing coronary angiography.MethodsThe number of EPCs and CACs were measured in the blood of 48 patients undergoing coronary angiography. Patients with acute coronary syndromes were excluded.ResultsCompared with patients without angiographically significant CAD, the number of EPCs was increased (1.11 ± 2.50 vs. 4.01 ± 3.70 colonies/well, p = 0.004) and the number of CACs trended higher (175 ± 137 vs. 250 ± 160 cells per mm2, p = 0.09) among patients with significant CAD. The highest levels of EPCs were isolated from patients subsequently selected for revascularization (5.03 ± 4.10 colonies/well).ConclusionsIn patients referred for coronary angiography, higher numbers of EPCs, and a trend toward higher numbers of CACs, were associated with the presence of significant CAD, and EPC number correlated with maximum angiographic stenosis severity. Endothelial progenitor cell levels were highest in patients with CAD selected for revascularization

    Triangular Sierpinski Microwave Band-Stop Resonators for K-Band Filtering

    Get PDF
    Triangular resonators re-shaped with Sierpinski geometry were designed, manufactured, and tested for potential applications in the K-Band. Prototypes of band-stop filters working around 20 GHz and 26 GHz, interesting for RADAR and satellite communications, were studied in a coplanar waveguide (CPW) configuration. Single and coupled structures were analyzed to give evidence for: (i) the tuning of the resonance frequency by increasing the internal complexity of the triangle and (ii) resonance enhancement when coupled structures are considered. The exploited devices were part of the more extended family of metamaterial-inspired structures, and they were studied for their heuristic approach to the prediction of the spectrum using experimental results supported by electromagnetic simulations. As a result, a Sierpinski resonator, not only fed into but also fully embedded into a CPW environment, had a frequency response that was not easily determined by classical theoretical approaches

    MEMS-Switched Triangular and U-Shaped Band-Stop Resonators for K-Band Operation

    Get PDF
    Triangular resonators re-shaped into Sierpinski geometry and U-shaped resonators were designed, linking them with single-pole-double-through (SPDT) RF MEMS switches to provide frequency tuning for potential applications in the K-Band. Prototypes of band-stop narrowband filters working around 20 GHz and 26 GHz, interesting for RADAR and satellite communications, were studied in a coplanar waveguide (CPW) configuration, and the tuning was obtained by switching between two paths of the devices loaded with different resonators. As a result, dual-band operation or fine-tuning could be obtained depending on the choice of the resonator, acting as a building block. The studied filters belong to the more general group of devices inspired by a metamaterial design

    High-resolution tracking in a GEM-Emulsion detector

    Full text link
    SHiP (Search for Hidden Particles) is a beam dump experiment proposed at the CERN SPS aiming at the observation of long lived particles very weakly coupled with ordinary matter mostly produced in the decay of charmed hadrons. The beam dump facility of SHiP is also a copious factory of neutrinos of all three kinds and therefore a dedicated neutrino detector is foreseen in the SHiP apparatus. The neutrino detector exploits the Emulsion Cloud Chamber technique with a modular structure, alternating walls of target units and planes of electronic detectors providing the time stamp to the event. GEM detectors are one of the possible choices for this task. This paper reports the results of the first exposure to a muon beam at CERN of a new hybrid chamber, obtained by coupling a GEM chamber and an emulsion detector. Thanks to the micrometric accuracy of the emulsion detector, the position resolution of the GEM chamber as a function of the particle inclination was evaluated in two configurations, with and without the magnetic fiel

    22q11 Deletion Syndrome and Urogenital Manifestations: A Clinicopathological Case Report.

    Get PDF
    Deletion in the chromosomal region 22q11 results from the abnormal development of the third and fourth pharyngeal pouches during embryonic life and presents an expansive phenotype with more than 180 clinical features described that involve every organ and system. A 23-year-old African woman presented for the first trimester echography, which revealed an isolated anechoic structure suggesting a ureteral dilatation. The suspicion of a malposition of great arteries in the second trimester indicated an amniocentesis leading to a diagnosis of 22q11 deletion. At 32 weeks, the patient was admitted for premature rupture of membranes and gave birth 2 weeks later to a male newborn who presented a respiratory distress syndrome and probably died secondary to a tracheal stenosis. Necropsy revealed typical clinical features of 22q11 deletion associated with left renal agenesis, hypospadias, and penile hypoplasia. We report a case of 22q11 deletion syndrome with typical clinical features associated with urogenital manifestations suspected at the first trimester ultrasound

    An evidence map and synthesis review with meta-analysis on the risk of incisional hernia in colorectal surgery with standard closure.

    Get PDF
    Purpose To assess the incidence of incisional hernia (IH) across various type of incisions in colorectal surgery (CS) creating a map of evidence to define research trends, gaps and areas of future interest. Methods Systematic review of PubMed and Scopus from 2010 onwards. Studies included both open (OS) and laparoscopic (LS). The primary outcome was incidence of IH 12 months after index procedure, secondary outcomes were the study features and their influence on reported proportion of IH. Random effects models were used to calculate pooled proportions. Meta-regression models were performed to explore heterogeneity. Results Ninetyone studies were included reporting 6473 IH. The pooled proportions of IH for OS were 0.35 (95% CI 0.27–0.44) I2 0% in midline laparotomies and 0.02 (95% CI 0.00–0.07), I2 52% for off-midline. In case of LS the pooled proportion of IH for midline extraction sites were 0.10 (95% CI 0.07–0.16), I2 58% and 0.04 (95% CI 0.03–0.06), I2 86% in case of off-midline. In Port-site IH was 0.02 (95% CI 0.01–0.04), I2 82%, and for single incision surgery (SILS) of 0.06—95% CI 0.02–0.15, I2 81%. In case of stoma reversal sites was 0.20 (95% CI 0.16–0.24). Conclusion Midline laparotomies and stoma reversal sites are at high risk for IH and should be considered in research of preventive strategies of closure. After laparoscopic approach IH happens mainly by extraction sites incisions specially midline and also represent an important area of analysis.pre-print3102 K

    Characterization and Performance of PADME's Cherenkov-Based Small-Angle Calorimeter

    Full text link
    The PADME experiment, at the Laboratori Nazionali di Frascati (LNF), in Italy, will search for invisible decays of the hypothetical dark photon via the process e+eγAe^+e^-\rightarrow \gamma A', where the AA' escapes detection. The dark photon mass range sensitivity in a first phase will be 1 to 24 MeV. We report here on measurement and simulation studies of the performance of the Small-Angle Calorimeter, a component of PADME's detector dedicated to rejecting 2- and 3-gamma backgrounds. The crucial requirement is a timing resolution of less than 200 ps, which is satisfied by the choice of PbF2_2 crystals and the newly released Hamamatsu R13478UV photomultiplier tubes (PMTs). We find a timing resolution of 81 ps (with double-peak separation resolution of 1.8 ns) and a single-crystal energy resolution of 5.7%/E\sqrt{E} with light yield of 2.07 photo-electrons per MeV, using 100 to 400 MeV electrons at the Beam Test Facility of LNF. We also propose the investigation of a two-PMT solution coupled to a single PbF2_2 crystal for higher-energy applications, which has potentially attractive features.Comment: 12 pages, 19 figures. v2: added section on radiation damage studie

    Near-field microwave techniques for micro – and nano - scale characterization in materials science

    Get PDF
    In this paper, the basic principles of Near-Field Microscopy will be reviewed with focus on the micro- and nano-scale resolution configurations for material science measurements. Results on doping profile, dielectric and magnetic properties will be presented, with details on the calibration protocols needed for quantitative estimation of the dielectric constant and of the permeability

    Argatroban anticoagulation for adult extracorporeal membrane oxygenation : a systematic review

    Get PDF
    Background: Heparin is the widely used anti-coagulation strategy for patients on extracorporeal membrane oxygenation (ECMO). Nevertheless, heparin-induced thrombocytopenia (HIT) and acquired anti-thrombin (AT) deficiency preclude the use of heparin requiring utilization of an alternative anticoagulant agent. Direct thrombin inhibitors are being proposed as potential alternatives with argatroban as one of the main agents. We aimed to review the evidence with regard to safety and efficacy of argatroban as a potential definitive alternative to heparin in the adult patient population undergoing ECMO support. Methods: A web-based systematic literature search was performed in Medline (PubMed) and Embase from inception until June 18, 2020. Results: The search identified 13 publications relevant to the target (4 cohort studies and 9 case series). Case reports and case series with less than 3 cases were not included in the qualitative synthesis. The aggregate number of argatroban treated patients on ECMO was n = 307. In the majority of studies argatroban was used as a continuous infusion without loading dose. Starting doses on ECMO varied between 0.05 and 2 μg/kg/min and were titrated to achieve the chosen therapeutic target range. The activated partial thormboplastin time (aPTT) was the anticoagulation parameter used for monitoring purposes in most studies, whereas some utilized the activated clotting time (ACT). Optimal therapeutic targets varied between 43-70 and 60-100 seconds for aPTT and between 150-210 and 180-230 seconds for ACT. Bleeding and thromboembolic complication rates were comparable to patients treated with unfractionated heparin (UFH). Conclusions: Argatroban infusion rates and anticoagulation target ranges showed substantial variations. The rational for divergent dosing and monitoring approaches are discussed in this paper. Argatroban appears to be a potential alternative to UFH in patients requiring ECMO. To definitively establish its safety, efficacy and ideal dosing strategy, larger prospective studies on well-defined patient populations are warranted

    Telemedicine and telehealth: an Italian and UK perspective

    Get PDF
    On January 30, 2020, the Director-General of the World Health Organization (WHO) declared the international outbreak of new coronavirus 2019-nCoV (Public Health Emergency of International Concern -PHEIC), as enshrined in the International Health Regulations (IHR, 2005). The current pandemic has uncovered our vulnerability and fears turning our lives upside down. We have been forced to a more resourceful approach with a view to contain and limit potential damage. The current events have put significant strain on hospital organisations all over the world
    corecore