112 research outputs found

    Investigations of laser pumped gas cell atomic frequency standard

    Get PDF
    The performance characteristics of a rubidium gas cell atomic frequency standard might be improved by replacing the standard rubidium discharge lamp with a single mode laser diode. Aspects of the laser pumped gas cell atomic clock studied include effects due to laser intensity, laser detuning, and the choice of the particular atomic absorption line. Results indicate that the performance of the gas cell clock may be improved by judicious choice of the operating parameters of the laser diode. The laser diode also proved to be a valuable tool in investigating the operation of the conventional gas cell clock. Results concerning linewidths, the light shift effect and the effect of isotopic spin exchange in the conventional gas cell clock are reported

    Laser induced asymmetry and inhomogeneous broadening of the microwave lineshape of a gas cell atomic frequency standard

    Get PDF
    The possibility of replacing the RF discharge lamp in a rubidium gas cell clock with a single mode laser diode is addressed. Since the short term stability of the rubidium frequency standard is limited by the shot noise of the photodetector, an increased signal-to-noise ratio due to more efficient laser diode optical pumping might improve the short term performance. Because the emission wavelength of the laser diode can be tuned, improved long term performance could be gained through the control of the light shift effect. However, due to the nature of the gas cell frequency standard, various physical phenomena are strongly coupled in their effect on the frequency output, and thus careful consideration must be given to any change in one parameter because of its interrelation with other parameters. Some investigations concerning the coupled effect of the optical and microwave fields in the rubidium atomic clock are reported. It is shown that this type of coupling is an important consideration for any attempt to incorporate a laser diode into a gas cell clock

    Monte Carlo simulations of precise timekeeping in the Milstar communication satellite system

    Get PDF
    The Milstar communications satellite system will provide secure antijam communication capabilities for DOD operations into the next century. In order to accomplish this task, the Milstar system will employ precise timekeeping on its satellites and at its ground control stations. The constellation will consist of four satellites in geosynchronous orbit, each carrying a set of four rubidium (Rb) atomic clocks. Several times a day, during normal operation, the Mission Control Element (MCE) will collect timing information from the constellation, and after several days use this information to update the time and frequency of the satellite clocks. The MCE will maintain precise time with a cesium (Cs) atomic clock, synchronized to UTC(USNO) via a GPS receiver. We have developed a Monte Carlo simulation of Milstar's space segment timekeeping. The simulation includes the effects of: uplink/downlink time transfer noise; satellite crosslink time transfer noise; satellite diurnal temperature variations; satellite and ground station atomic clock noise; and also quantization limits regarding satellite time and frequency corrections. The Monte Carlo simulation capability has proven to be an invaluable tool in assessing the performance characteristics of various timekeeping algorithms proposed for Milstar, and also in highlighting the timekeeping capabilities of the system. Here, we provide a brief overview of the basic Milstar timekeeping architecture as it is presently envisioned. We then describe the Monte Carlo simulation of space segment timekeeping, and provide examples of the simulation's efficacy in resolving timekeeping issues

    Laser-noise-induced correlations and anti-correlations in Electromagnetically Induced Transparency

    Full text link
    High degrees of intensity correlation between two independent lasers were observed after propagation through a rubidium vapor cell in which they generate Electromagnetically Induced Transparency (EIT). As the optical field intensities are increased, the correlation changes sign (becoming anti-correlation). The experiment was performed in a room temperature rubidium cell, using two diode lasers tuned to the 85^{85}Rb D2D_2 line (λ=780\lambda = 780nm). The cross-correlation spectral function for the pump and probe fields is numerically obtained by modeling the temporal dynamics of both field phases as diffusing processes. We explored the dependence of the atomic response on the atom-field Rabi frequencies, optical detuning and Doppler width. The results show that resonant phase-noise to amplitude-noise conversion is at the origin of the observed signal and the change in sign for the correlation coefficient can be explained as a consequence of the competition between EIT and Raman resonance processes.Comment: Accepted for publication in EPJ

    Testis: Germ cell tumors

    Get PDF
    Review on Testis: Germ cell tumors, with data on clinics, and the genes involved

    The ac stark shift and space-borne rubidium atomic clocks

    Get PDF
    open7sìDue to its small size, low weight, and low power consumption, the Rb atomic frequency standard (RAFS) is routinely the first choice for atomic timekeeping in space. Consequently, though the device has very good frequency stability (rivaling passive hydrogen masers), there is interest in uncovering the fundamental processes limiting its long-term performance, with the goal of improving the device for future space systems and missions. The ac Stark shift (i. e., light shift) is one of the more likely processes limiting the RAFS' long-term timekeeping ability, yet its manifestation in the RAFS remains poorly understood. In part, this comes from the fact that light-shift induced frequency fluctuations must be quantified in terms of the RAFS' light-shift coefficient and the output variations in the RAFS' rf-discharge lamp, which is a nonlinear inductively-couple plasma (ICP). Here, we analyze the light-shift effect for a family of 10 on-orbit Block-IIR GPS RAFS, examining decade-long records of their on-orbit frequency and rf-discharge lamp fluctuations. We find that the ICP's light intensity variations can take several forms: deterministic aging, jumps, ramps, and non-stationary noise, each of which affects the RAFS' frequency via the light shift. Correlating these light intensity changes with RAFS frequency changes, we estimate the light-shift coefficient, K-LS, for the family of RAFS: K-LS = -(1.9 +/- 0.3) x 10(-12) /%. The 16% family-wide variation in K-LS indicates that while each RAFS may have its own individual K-LS, the variance of K-LS among similarly designed RAFS can be relatively small. Combining K-LS with our estimate of the ICP light intensity's non-stationary noise, we find evidence that random-walk frequency noise in high-quality space-borne RAFS is strongly influenced by the RAFS' rf-discharge lamp via the light shift effect. Published by AIP Publishing.openFormichella, V.; Camparo, J.; Sesia, I.; Signorile, G.; Galleani, L.; Huang, M.; Tavella, P.Formichella, V.; Camparo, J.; Sesia, Ilaria; Signorile, Giovanna; Galleani, L.; Huang, M.; Tavella, Patrizi

    Le lymphome primitif de la prostate : à propos d’un cas avec revue de la literature

    Get PDF
    Le lymphome primitif de la prostate est une affection maligne rare. Les patients présentent initialement des signes urinaires locaux et des signes généraux. Plusieurs traitements ont été utilisés comme la prostatectomie radicale, la radiothérapie ou des associations de chimiothérapie et de radiothérapie. Une revue de la littérature fait état du mauvais pronostic du lymphome de la prostate, le diagnostic se faisant souvent à un stade tardif. Nous rapportons le cas d’un patient âgé de 73 ans présentant une rétention aiguë d’urines dans un contexte de constipation opiniâtre avec amaigrissement sévère. Il était diabétique, aux antécédents de carcinome urothélial de stade pT1 et de grade G3, traité par résection transurétrale et BCG thérapie. L’examen clinique a révélé une prostate très augmentée de volume, ce qui a été confirmé par les examens d’imagerie. L’analyseanatomo-pathologique des biopsies réalisées par voie transrectale a mis en évidence un lymphome malin non Hodgkinien de type B primitif de la prostate. La prise en charge a consisté en une chimiothérapie. Malgré une régression considérable du volume tumoral à partir de la troisièmesemaine, le patient est décédé au lendemain de son 5ème cycle de chimiothérapie

    Phase-Control of Photoabsorption in Optically Dense Media

    Get PDF
    We present a self-consistent theory, as well as an illustrative application to a realistic system, of phase control of photoabsorption in an optically dense medium. We demonstrate that, when propagation effects are taken into consideration, the impact on phase control is significant. Independently of the value of the initial phase difference between the two fields, over a short scaled distance of propagation, the medium tends to settle the relative phase so that it cancels the atomic excitation. In addition, we find some rather unusual behavior for an optically thin layer.Comment: 5 pages, 3 figures, submitted to PR

    Phase-dependent spectra in a driven two-level atom

    Full text link
    We propose a method to observe phase-dependent spectra in resonance fluorescence, employing a two-level atom driven by a strong coherent field and a weak, amplitude-fluctuating field. The spectra are similar to those which occur in a squeezed vacuum, but avoid the problem of achieving squeezing over a 4π4\pi solid angle. The system shows other interesting features, such as pronounced gain without population inversion.Comment: 4 pages and 4 figures. Submitted to Phys. Rev. Let
    corecore