25 research outputs found

    Dependence of norfloxacin diffusion across bilayers on lipid composition.

    Get PDF
    Antibiotic resistance is a growing concern in medicine and raises the need to develop and design new drug molecules that can efficiently inhibit bacterial replication. Spurring the passive uptake of the drug molecules is an obvious solution. However our limited understanding of drug-membrane interactions due to the presence of an overwhelming variety of lipids constituting cellular membranes and the lack of facile tools to probe the bio-physical interactions between drugs and lipids imposes a major challenge towards developing new drug molecules that can enter the cell via passive diffusion. Here, we used a label-free micro-fluidic platform combined with giant unilamellar lipid vesicles to investigate the permeability of membranes containing mixtures of DOPE and DOPG in DOPC, leading to a label-free measurement of passive membrane-permeability of autofluorescent antibiotics. A fluoroquinolone drug, norfloxacin was used as a case study. Our results indicate that the diffusion of norfloxacin is strongly dependent on the lipid composition which is not expected from the traditional octanol-lipid partition co-efficient assay. The anionic lipid, DOPG, slows the diffusion process whereas the diffusion across liposomes containing DOPE increases with higher DOPE concentration. Our findings emphasise the need to investigate drug-membrane interactions with focus on the specificity of drugs to lipids for efficient drug delivery, drug encapsulation and targeted drug-delivery.SP and UFK acknowledge funding from an ERC starting grant, Passmembrane 261101 and an EPSRC grant GRAPHTED, EP/ K016636/1, and JC acknowledges the support from an Internal Graduate Studentship, Trinity College, Cambridge and a Research Studentship from the Cambridge Philosophical Society.This is the final version of the article. It first appeared from the Royal Society of Chemistry via http://dx.doi.org/10.1039/C5SM02371

    Breaching the Barrier: Quantifying Antibiotic Permeability across Gram-negative Bacterial Membranes.

    Get PDF
    The double-membrane cell envelope of Gram-negative bacteria is a sophisticated barrier that facilitates the uptake of nutrients and protects the organism from toxic compounds. An antibiotic molecule must find its way through the negatively charged lipopolysaccharide layer on the outer surface, pass through either a porin or the hydrophobic layer of the outer membrane, then traverse the hydrophilic peptidoglycan layer only to find another hydrophobic lipid bilayer before it finally enters the cytoplasm, where it typically finds its target. This complex uptake pathway with very different physico-chemical properties is one reason that Gram-negative are intrinsically protected against multiple classes of antibiotic-like molecules, and is likely the main reason that in vitro target-based screening programs have failed to deliver novel antibiotics for these organisms. Due to the lack of general methods available for quantifying the flux of drugs into the cell, little is known about permeation rates, transport pathways and accumulation at the target sites for particular molecules. Here we summarize the current tools available for measuring antibiotic uptake across the different compartments of Gram-negative bacteria

    Characterization of lipid composition and diffusivity in OLA generated vesicles.

    Get PDF
    Giant Unilamellar Vesicles (GUVs) are a versatile tool in many branches of science, including biophysics and synthetic biology. Octanol-Assisted Liposome Assembly (OLA), a recently developed microfluidic technique enables the production and testing of GUVs within a single device under highly controlled experimental conditions. It is therefore gaining significant interest as a platform for use in drug discovery, the production of artificial cells and more generally for controlled studies of the properties of lipid membranes. In this work, we expand the capabilities of the OLA technique by forming GUVs of tunable binary lipid mixtures of DOPC, DOPG and DOPE. Using fluorescence recovery after photobleaching we investigated the lateral diffusion coefficients of lipids in OLA liposomes and found the expected values in the range of 1 μm2/s for the lipid systems tested. We studied the OLA derived GUVs under a range of conditions and compared the results with electroformed vesicles. Overall, we found the lateral diffusion coefficients of lipids in vesicles obtained with OLA to be quantitatively similar to those in vesicles obtained via traditional electroformation. Our results provide a quantitative biophysical validation of the quality of OLA derived GUVs, which will facilitate the wider use of this versatile platform.Friedrich Naumann Foundation; Jane Bourque-Driscoll Fund; Cambridge Philosophical Society; Winton Programme for the Physics of Sustainability; Engineering and Physical Sciences Research Council; Wellcome Trust; ER

    Direct Optofluidic Measurement of the Lipid Permeability of Fluoroquinolones.

    Get PDF
    Quantifying drug permeability across lipid membranes is crucial for drug development. In addition, reduced membrane permeability is a leading cause of antibiotic resistance in bacteria, and hence there is a need for new technologies that can quantify antibiotic transport across biological membranes. We recently developed an optofluidic assay that directly determines the permeability coefficient of autofluorescent drug molecules across lipid membranes. Using ultraviolet fluorescence microscopy, we directly track drug accumulation in giant lipid vesicles as they traverse a microfluidic device while exposed to the drug. Importantly, our measurement does not require the knowledge of the octanol partition coefficient of the drug - we directly determine the permeability coefficient for the specific drug-lipid system. In this work, we report measurements on a range of fluoroquinolone antibiotics and find that their pH dependent lipid permeability can span over two orders of magnitude. We describe various technical improvements for our assay, and provide a new graphical user interface for data analysis to make the technology easier to use for the wider community.The work was supported by an ERC Consolidator grant “DesignerPores” awarded to UFK. JC acknowledges support from the BBSRC. MS was supported by the Friedrich Naumann Foundation for Freedom and the Swiss- European Mobility Programme. KAN was supported by the Erasmus Plus student exchange programme. SHA is supported by a Herchel Smith Postdoctoral Fellowship. SP acknowledges support from the Leverhulme Trust through an Early Career Fellowship (ECF-2013-444).This is the final version of the article. It first appeared from Nature Publishing Group at http://dx.doi.org/10.1038/srep32824

    Aerosol-jet-printed, conformable microfluidic force sensors.

    Get PDF
    Force sensors that are thin, low-cost, flexible, and compatible with commercial microelectronic chips are of great interest for use in biomedical sensing, precision surgery, and robotics. By leveraging a combination of microfluidics and capacitive sensing, we develop a thin, flexible force sensor that is conformable and robust. The sensor consists of a partially filled microfluidic channel made from a deformable material, with the channel overlaying a series of interdigitated electrodes coated with a thin, insulating polymer layer. When a force is applied to the microfluidic channel reservoir, the fluid is displaced along the channel over the electrodes, thus inducing a capacitance change proportional to the applied force. The microfluidic molds themselves are made of low-cost sacrificial materials deposited via aerosol-jet printing, which is also used to print the electrode layer. We envisage a large range of industrial and biomedical applications for this force sensor

    Aerosol-jet printing facilitates the rapid prototyping of microfluidic devices with versatile geometries and precise channel functionalization.

    Get PDF
    Microfluidics has emerged as a powerful analytical tool for biology and biomedical research, with uses ranging from single-cell phenotyping to drug discovery and medical diagnostics, and only small sample volumes required for testing. The ability to rapidly prototype new designs is hugely beneficial in a research environment, but the high cost, slow turnaround, and wasteful nature of commonly used fabrication techniques, particularly for complex multi-layer geometries, severely impede the development process. In addition, microfluidic channels in most devices currently play a passive role and are typically used to direct flows. The ability to "functionalize" the channels with different materials in precise spatial locations would be a major advantage for a range of applications. This would involve incorporating functional materials directly within the channels that can partake in, guide or facilitate reactions in precisely controlled microenvironments. Here we demonstrate the use of Aerosol Jet Printing (AJP) to rapidly produce bespoke molds for microfluidic devices with a range of different geometries and precise "in-channel" functionalization. We show that such an advanced microscale additive manufacturing method can be used to rapidly design cost-efficient and customized microfluidic devices, with the ability to add functional coatings at specific locations within the microfluidic channels. We demonstrate the functionalization capabilities of our technique by specifically coating a section of a microfluidic channel with polyvinyl alcohol to render it hydrophilic. This versatile microfluidic device prototyping technique will be a powerful aid for biological and bio-medical research in both academic and industrial contexts

    Indole Pulse Signalling Regulates the Cytoplasmic pH of E. coli in a Memory-Like Manner.

    Get PDF
    Bacterial cells are critically dependent upon pH regulation. Here we demonstrate that indole plays a critical role in the regulation of the cytoplasmic pH of Escherichia coli. Indole is an aromatic molecule with diverse signalling roles. Two modes of indole signalling have been described: persistent and pulse signalling. The latter is illustrated by the brief but intense elevation of intracellular indole during stationary phase entry. We show that under conditions permitting indole production, cells maintain their cytoplasmic pH at 7.2. In contrast, under conditions where no indole is produced, the cytoplasmic pH is near 7.8. We demonstrate that pH regulation results from pulse, rather than persistent, indole signalling. Furthermore, we illustrate that the relevant property of indole in this context is its ability to conduct protons across the cytoplasmic membrane. Additionally, we show that the effect of the indole pulse that occurs normally during stationary phase entry in rich medium remains as a "memory" to maintain the cytoplasmic pH until entry into the next stationary phase. The indole-mediated reduction in cytoplasmic pH may explain why indole provides E. coli with a degree of protection against stresses, including some bactericidal antibiotics.The Leverhulme Trus

    Conformable and robust microfluidic force sensors to enable precision joint replacement surgery

    Get PDF
    Balancing forces within weight-bearing joints such as the hip during joint replacement is essential for implant longevity. Minimising implant failure and the corresponding need for expensive and difficult revision surgery is vital to both improve the quality of life of the patient and lighten the burden on overstretched healthcare systems. However, balancing forces during total hip replacements is currently subjective and entirely dependent on surgical skill, as there are no sensors currently on the market that are capable of providing quantitative force feedback within the small and complex geometry of the hip joint. Here, we solve this unmet clinical need by presenting a thin and conformable microfluidic force sensor, which is compatible with the standard surgical procedure. The sensors are fabricated via additive manufacturing, using a combination of 3D and aerosol-jet printing. We optimised the design using finite element modelling, then incorporated and calibrated our sensors in a 3D printed model hip implant. Using a bespoke testing rig, we demonstrated high sensitivity at typical forces experienced following implantation of hip replacements. We anticipate that these sensors will aid soft tissue balancing and implant positioning, thereby increasing the longevity of hip replacements. These sensors thus represent a powerful new surgical tool for a range of orthopaedic procedures where balancing forces is crucial
    corecore