22 research outputs found

    Buckling curves of hot rolled H steel sections submitted to fire

    Full text link
    Report of the research work at the base of the design equation introduced in Eurocode 3 (EN 1993-1-2) for the stability of steel columns under axial loading or combined axial and bending loading

    Influence of variability of material mechanical properties on seismic performance of steel and steel-concrete composite structures

    Get PDF
    Modern standards for constructions in seismic zones allow the construction of buildings able to dissipate the energy of the seismic input through an appropriate location of cyclic plastic deformations involving the largest possible number of structural elements, forming thus a global collapse mechanisms without failure and instability phenomena both at local and global level. The key instrument for this purpose is the capacity design approach, which requires an appropriate selection of the design forces and an accurate definition of structural details within the plastic hinges zones, prescribing at the same time the oversizing of non-dissipative elements that shall remain in the elastic field during the earthquake. However, the localization of plastic hinges and the development of the global collapse mechanism is strongly influenced by the mechanical properties of materials, which are characterized by an inherent randomness. This variability can alter the final structural behaviour not matching the expected performance. In the present paper, the influence of the variability of material mechanical properties on the structural behaviour of steel and steel/concrete composite buildings is analyzed, evaluating the efficiency of the capacity design approach as proposed by Eurocode 8 and the possibility of introducing an upper limitation to the nominal yielding strength adopted in the design

    Valorisatie project - natuurlijk brandconcept : eindrapport /

    No full text
    CEC overeenkomst 7215-PA/PB/PC - 057 : verslagperiode 01.07.2000 - 30.06.200

    Fire Safety - Fire safety and fire resistance design of steel buildings according to Eurocode 3

    Full text link
    Ce livre traite, dans ses trois premiers chapitres, de la sécurité incendie et du calcul de la résistance au feu des structures de bâtiments en acier selon l'Eurocode 3. Le chapitre 1 définit les objectifs de la sécurité incendie sur la base du déroulement d'un incendie et examine les mesures que le concepteur peut prendre afin de répondre aux exigences de sécurité incendie et aux exigences réglementaires. Le chapitre 2 traite du calcul de la résistance au feu de structures en acier pour ce qui concerne le critère de capacité portante. Un modèle de calcul simple est donné dans les Eurocodes pour les éléments tendus, les colonnes et les poutres soumises ou non au déversement. Pour le calcul des poutres intégrées, qu’elles soient protégées ou non, on peut utiliser un modèle de calcul avancé, mais une méthode alternative simple est décrite dans cet ouvrage. Le chapitre 3 traite de l'ingénierie de la sécurité incendie, une discipline relativement nouvelle qui utilise les modèles physiques pour décrire le déroulement d'un incendie et ses effets sur le bâtiment et ses occupants. On évoque quatre situations qui nécessitent l’utilisation de l'ingénierie de la sécurité incendie, à savoir: les feux localisés, les feux de compartiment (avec ou sans embrasement généralisé), le cas des structures en acier situées à l'extérieur du bâtiment et celui où l’on considère le comportement d’ensemble d’une ossature. Ce dernier cas est illustré par l’étude de l’effet membranaire d’un système de plancher. Enfin, le chapitre 4 contient treize tableaux de dimensionnement qui donnent directement certains paramètres de calcul comme la réduction de la limite d’élasticité efficace, celle du module d’élasticité de l’acier, le niveau de chargement en situation d’incendie, le facteur de massiveté des sections en I, la température atteinte dans l’acier après un certain temps (pour divers valeurs de ce facteur de massiveté) et la température critique des colonnes (en fonction de leur niveau de chargement et de leur élancement)

    Simplified design method for slim floor beams exposed to fire

    Full text link
    peer reviewedOne of the most important advantages of using the slim or integrated floor beams (SFB and IFB supporting full concrete slab, precast units or steel deck composite slab) is a significant fire resistance. However, despite of its common use in construction, no specific simplified calculation methods for the fire resistance of IFB and SFB exist in the Eurocode. This study, based on existing calculation rules of Eurocode 4, a parametrical study using soft-ware SAFIR and fire tests results, define a set of formulas to determine the thermal field and to deduce the mechanical resistance from classical plastic design

    Branveiligheid - Brandveiligheid en berekening van de brandwerendheid van staalconstructies voor gebouwen volgens Eurocode 3

    Full text link
    Dit boek behandelt in de eerste drie hoofdstukken het onderwerp brandveiligheid en de berekening van de brandwerendheid van staalconstructies voor gebouwen volgens Eurocode 3. Hoofdstuk 1 omschrijft de doelstellingen van brandveiligheid aan de hand van het gedrag van een brand en bespreekt de maatregelen die een ontwerper kan nemen om te voldoen aan de eisen voor brandveiligheid en de wettelijk eisen. Hoofdstuk 2 gaat over het berekenen van de brandwerendheid van een staalconstructie met betrekking tot bezwijken. Een eenvoudig berekeningsmodel volgens Eurocode 3 wordt besproken en is geschikt voor trekstaven, niet-kipgevoelige liggers, kolommen én kipgevoelige liggers. Voor de berekening van geïntegreerde liggers, zowel onbekleed als bekleed wordt een geavanceerd rekenmodel gebruikt en wordt tevens een alternatieve vereenvoudigde methode voorgesteld. Hoofdstuk 3 behandelt het onderwerp fire safety engineering; een relatief nieuw vakgebied, waarbij fysische modellen worden gebruikt om het gedrag van een brand – en het effect hiervan op bouwwerken en de gebruikers – te beschrijven. Er worden vier situaties besproken die met fire safety engineering in de praktijk al zijn te berekenen: lokale branden, compartimentsbranden (zonder én met flashover), staalconstructies die zich buiten het gebouw bevinden in de buitenlucht én het systeemgedrag van een staalconstructie. Dit laatste wordt geillustreerd aan de hand van een staalplaat-betonvloer waarbij het membraaneffect in acht wordt genomen. Hoofdstuk 4 tenslotte bevat dertien ontwerptabellen voor het eenvoudig bepalen van een aantal rekenparameters zoals de afname van de effectieve vloeigrens en de elasticiteitsmodulus, de reductiefactor op de belastingen bij brand, de profielfactoren voor I-profielen, de staaltemperatuur na een bepaalde tijd (in functie van de profielfactor) en de kritieke staaltemperatuur voor kolommen (in functie van de benuttinggraad en slankheid)

    Characterization of an Insulating Material with regards to ECCS. Recommendations for the Fire Safety of Steel Structures

    Full text link
    How to characterize an insulating product by an apparent constant thermal conductivit

    Effects caused on the structure by localised fires in large compartments

    Full text link
    A description is given of the small-scale steadstate tests made by Hasemi in Japan with the aim of measuring the heat flux transmitted by a localised fire to the ceiling or to a beam located above the fire. The parameters that influence the heat flux have been mentionned and an empirical model has been proposed, allowing the prediction of the heat flux.It is shown here how the model has been applied to full-scale transient fires. The model allows the calculation of the transient temperature in steel beams with a reasonable accuracy

    A Simple Model for the Fire Resistance of Axially-Loaded Members According to Eurocode 3

    Full text link
    New buckling curves have been developed for axialy loaded steel members subjected to fire. The model is based on extensive numerical simulations calibrated on several dozens of full scale experimental test results. This model has been subsequently included in Eurocode 3