4 research outputs found

    The role of frequency doubling perimetry in the diagnosis of glaucoma: screening in employees of a public hospital in an urban area of São Paulo

    Get PDF
    PURPOSE: To study the prevalence of glaucoma in employees of a public hospital in São Paulo and to analyze the role of frequency doubling perimetry along with non-contact tonometry and direct ophthalmoscopy, in the screening for glaucoma. METHODS: 612 employees of the Central Hospital of the Santa Casa de São Paulo were evaluated from October 15 to 20, 2000; 438 were women and 174 men, with mean age of 45.05±7.7 years (range, 35 to 81 years); 437 were white, 104 mulatto, 43 black and 28 Asian. All examinations were done by 10 eye specialists with experience in glaucoma. All employees had both eyes examined, by means of frequency doubling perimetry (FDT), ophthalmoscopy (FO), and non-contact tonometry (TNC). RESULTS: 159 (25.98%) subjects presented with at least one abnormal testing; 5 (3.14%) had high IOP (TNC+); 13 (8.17%) presented suspicious disk (FO+); 110 (69.18%) presented abnormal FDT (FDP+); 8 (5.03%) TNC+ and FO+; 10 (6.28%) had TNC+ and FDT+; 9 (5.66%) presented FO+ and FDT+; 4 (2.51%) had TNC+, FO+ and FDT+; 12 (1.96%) individuals were diagnosed with glaucoma, four of whom (0.65%), with normal pressure glaucoma. CONCLUSIONS: Frequency doubling perimetry was found to be an important step in the screening for glaucoma in the study. Of the 12 individuals that had the diagnosis of glaucoma, 5 (41.6%) would not have been diagnosed if they had not undergone frequency doubling perimetry.OBJETIVO: Estudar a prevalência de glaucoma, em funcionários da Santa Casa de Misericórdia de São Paulo e analisar a validade da inclusão da perimetria de freqüência dupla junto à tonometria de não-contato e à oftalmoscopia direta, na triagem para glaucoma. MÉTODOS: Foram examinados 612 funcionários voluntários, 438 mulheres e 174 homens, com idade média de 45,05±7,7 anos. Eram 437 da raça branca, 104 mulatos, 43 da raça negra e 28 da raça amarela. Todos os funcionários tiveram ambos os olhos examinados por especialistas em glaucoma, que realizaram os seguintes exames: perimetria de freqüência dupla (FDT), oftalmoscopia direta (FO), tonometria de não-contato (TNC). RESULTADOS: Dos 612 indivíduos triados, 159 (25,98%) apresentaram alguma anormalidade em pelo menos um dos exames: 5 (3,14%) apresentaram pressão intra-ocular elevada (TNC+); 13 (8,17%) apresentaram oftalmoscopia suspeita (FO+); 110 (69,18%) apresentaram perimetria de freqüência dupla alterado (FDT+); 8 (5,03%) TNC+ e FO+; 10 (6,28%) TNC+ e FDT+; 9 (5,66%) FO+ e FDT+; 4 (2,51%) TNC+, FO+ e FDT+. Foram detectados 12 (1,96%) indivíduos com glaucoma, quatro dos quais (0,65%) com glaucoma de pressão normal. CONCLUSÕES: A perimetria de freqüência dupla mostrou-se útil para o rastreamento de glaucoma dentro da amostragem estudada. Do total de 12 indivíduos que tiveram o diagnóstico de glaucoma, 5 (41,6%) não teriam sido detectados se não tivessem sido submetidos a perimetria de freqüência dupla.Santa Casa de São Paulo Departamento de OftalmologiaSanta Casa de Misericórdia de São Paulo Departamento de Oftalmologia Setor de GlaucomaUniversidade Federal de São Paulo (UNIFESP) Departamento de OftalmologiaSanta Casa de São Paulo Faculdade de Ciências Médicas Departamento de OftalmologiaUNIFESP, Depto. de OftalmologiaSciEL

    Comparação entre a correção cilíndrica total e o equivalente esférico na realização da perimetria computadorizada Comparison between the full cylindrical correction and the spherical equivalent in the execution of automated perimetry

    No full text
    OBJETIVO: Verificar a existência de diferença estatisticamente significativa entre exames de campimetria computadorizada, realizados com a utilização da correção total e do equivalente esférico, em pacientes com ametropia cilíndrica de valores iguais ou maiores que 1,50 dioptrias. MÉTODOS: Vinte pacientes (35 olhos) foram submetidos a exame de campo visual, perimetria computadorizada Humphrey - estratégia SITA 24-2, usando em um exame a correção total e em outro o equivalente esférico. Foram utilizados como parâmetros de comparação os valores de Mean Deviation, Pattern Standard Deviation, perdas de fixação, falso-positivos, falso-negativos e duração dos exames. RESULTADOS: Os parâmetros Mean Deviation, Standard Pattern Deviation, falso-positivos, falso-negativos e duração do exame não apresentaram diferença estatisticamente significativa. A perda de fixação foi maior no grupo usando correção cilíndrica total, dado estatisticamente significante. CONCLUSÃO: Exames de campo visual realizados com equivalente esférico não mostram diferença na sensibilidade retínica quando comparados com o uso de correção cilíndrica total, dentro dos padrões adotados neste estudo.<br>PURPOSE: To compare the results in subjects undergoing visual field testing using the full cylindrical correction and the spherical equivalent. METHODS: Twenty patients (35 eyes) underwent visual field testing with Humphrey (SITA 24-2) perimetry using the full cylindrical correction and the spherical equivalent at a random sequence. Mean Deviation, Standard Pattern Deviation, fixation loss, false positive and false negative results and test duration were compared. RESULTS: No difference was found regarding Mean Deviation, Standard Pattern Deviation, false positive and false negative results and test duration. Fixation loss was significantly higher with the full cylindrical correction. CONCLUSION: Visual fields performed with the spherical equivalent show no change in the retinal sensitivity when compared to examinations done with the full cylindrical correction for the same eye
    corecore