1,840 research outputs found
Preserving the Delicate Balance Between Judicial Accountability and Independence: Merit Selection in the Post-White World
Background light measurements at the DUMAND site
Ambient light intensities at the DUMAND site, west of the island of Hawaii were measured around the one photoelectron level. Throughout the water column between 1,500m and 4,700m, a substantial amount of stimulateable bioluminescence is observed with a ship suspended detector. But non-stimulated bioluminescence level is comparable, or less than, K sup 40 background, when measured with a bottom tethered detector typical of a DUMAND optical module
Annual Variation in Habitat Use by White-footed Mice, Peromyscus leucopus: The Effects of Forest Patch Size, Edge and Surrounding Vegetation Type
White-footed Mice (Peromyscus leucopus) were trapped for two years in the exterior matrix, edge, and interior forest habitat sections of six forests patches in a fragmented agricultural landscape. We used data on the capture locations of P. leucopus individuals from the two years, which differed in rainfall (i.e., summer of 2000 with 50% more rain than summer of 1999), to assess how patch size, edge habitat, and surrounding habitat type influence habitat use and movements in populations of this forest habitat generalist. We found that the proportion of individuals subsequently captured in the forest edge from the exterior was 16 times greater in the wet year than in the dry year and approximately twice as many P. leucopus were not subsequently recaptured from the exterior matrix in the dry year compared to the wet year. For each year, captures between habitats did not differ in relation to patch size, edge forest habitat, or exterior matrix type. These results illustrate the generalist habitat preferences of P. leucopus, but emphasize annual variation in their behavior and distribution
Arrival directions of cosmic rays of E .4 EeV
The anisotropy of cosmic rays observed by the Utah Fly's Eye detector has been studied. Emphasis has been placed on examining distributions of events in galactic coordinates. No statistically significant departure from isotropy has been observed for energies greater than 0.4 EeV (1 EeV = 10 to the 18th power eV). Results of the standard harmonic analysis in right ascension are also presented
Recommended from our members
Thin liquid water clouds: their importance and our challenge
Many clouds important to the Earth’s energy balance contain small amounts of liquid water, yet despite many improvements, large differences in retrievals of their liquid water amount and particle size still must be resolved
Feasibility study for the Cryogenic Orbital Nitrogen Experiment (CONE)
An improved understanding of low gravity subcritical cryogenic fluid behavior is critical for the continued development of space based systems. Although early experimental programs provided some fundamental understanding of zero gravity cryogenic fluid behavior, more extensive flight data are required to design space based cryogenic liquid storage and transfer systems with confidence. As NASA's mission concepts evolve, the demand for optimized in-space cryogenic systems is increasing. Cryogenic Orbital Nitrogen Experiment (CONE) is an attached shuttle payload experiment designed to address major technological issues associated with on-orbit storage and supply of cryogenic liquids. During its 7 day mission, CONE will conduct experiments and technology demonstrations in active and passive pressure control, stratification and mixing, liquid delivery and expulsion efficiency, and pressurant bottle recharge. These experiments, conducted with liquid nitrogen as the test fluid, will substantially extend the existing low gravity fluid data base and will provide future system designers with vital performance data from an orbital environment
Radiation Testing of Electronics for the CMS Endcap Muon System
The electronics used in the data readout and triggering system for the
Compact Muon Solenoid (CMS) experiment at the Large Hadron Collider (LHC)
particle accelerator at CERN are exposed to high radiation levels. This
radiation can cause permanent damage to the electronic circuitry, as well as
temporary effects such as data corruption induced by Single Event Upsets. Once
the High Luminosity LHC (HL-LHC) accelerator upgrades are completed it will
have five times higher instantaneous luminosity than LHC, allowing for
detection of rare physics processes, new particles and interactions. Tests have
been performed to determine the effects of radiation on the electronic
components to be used for the Endcap Muon electronics project currently being
designed for installation in the CMS experiment in 2013. During these tests the
digital components on the test boards were operating with active data readout
while being irradiated with 55 MeV protons. In reactor tests, components were
exposed to 30 years equivalent levels of neutron radiation expected at the
HL-LHC. The highest total ionizing dose (TID) for the muon system is expected
at the inner-most portion of the CMS detector, with 8900 rad over ten years.
Our results show that Commercial Off-The-Shelf (COTS) components selected for
the new electronics will operate reliably in the CMS radiation environment
Long-term stability of TES satellite radiance measurements
The utilization of Tropospheric Emission Spectrometer (TES) Level 2 (L2) retrieval products for the purpose of assessing long term changes in atmospheric trace gas composition requires knowledge of the overall radiometric stability of the Level 1B (L1B) radiances. The purpose of this study is to evaluate the stability of the radiometric calibration of the TES instrument by analyzing the difference between measured and calculated brightness temperatures in selected window regions of the spectrum. The Global Modeling and Assimilation Office (GMAO) profiles for temperature and water vapor and the Real-Time Global Sea Surface Temperature (RTGSST) are used as input to the Optimal Spectral Sampling (OSS) radiative transfer model to calculate the simulated spectra. The TES reference measurements selected cover a 4-year period of time from mid 2005 through mid 2009 with the selection criteria being; observation latitudes greater than −30° and less than 30°, over ocean, Global Survey mode (nadir view) and retrieved cloud optical depth of less than or equal to 0.01. The TES cloud optical depth retrievals are used only for screening purposes and no effects of clouds on the radiances are included in the forward model. This initial screening results in over 55 000 potential reference spectra spanning the four year period. Presented is a trend analysis of the time series of the residuals (observation minus calculations) in the TES 2B1, 1B2, 2A1, and 1A1 bands, with the standard deviation of the residuals being approximately equal to 0.6 K for bands 2B1, 1B2, 2A1, and 0.9 K for band 1A1. The analysis demonstrates that the trend in the residuals is not significantly different from zero over the 4-year period. This is one method used to demonstrate that the relative radiometric calibration is stable over time, which is very important for any longer term analysis of TES retrieved products (L2), particularly well-mixed species such as carbon dioxide and methane
Therapeutic hypothermia for neonatal encephalopathy in low- and middle-income countries: a systematic review and meta-analysis.
Although selective or whole body cooling combined with optimal intensive care improves outcomes following neonatal encephalopathy in high-income countries, the safety and efficacy of cooling in low-and middle-income countries is not known.
Objective
We performed a systematic review and meta-analysis of all published randomised or quasi-randomised controlled trials of cooling therapy for neonatal encephalopathy in low-and middle-income countries.
Results
Seven trials, comprising a total of 567 infants were included in the meta-analysis. Most study infants had mild (15%) or moderate encephalopathy (48%) and did not receive invasive ventilation (88%). Cooling devices included water-circulating cooling caps, frozen gel packs, ice, water bottles, and phase-changing material. No statistically significant reduction in neonatal mortality was seen with cooling (risk ratio: 0.74, 95% confidence intervals: 0.44 to 1.25). Data on other neonatal morbidities and long-term neurological outcomes were insufficient.
Conclusion
Cooling therapy was not associated with a statistically significant reduction in neonatal mortality in low-and middle-income countries although the confidence intervals were wide and not incompatible with results seen in high-income countries. The apparent lack of treatment effect may be due to the heterogeneity and poor quality of the included studies, inefficiency of the low technology cooling devices, lack of optimal neonatal intensive care, sedation and ventilatory support, overuse of oxygen, or may be due to the intrinsic difference in the population, for example higher rates of perinatal infection, obstructed labor, intrauterine growth retardation and maternal malnutrition. Evaluation of the safety and efficacy of cooling in adequately powered randomised controlled trials is required before cooling is offered in routine clinical practice in low-and middle-income countries
- …