56 research outputs found

    Laryngological presentations and patient-reported outcome measures in Ehlers-Danlos syndrome

    Get PDF
    OBJECTIVE: This study aimed to characterise the laryngological presentations of Ehlers–Danlos syndrome and conduct a preliminary exploration of patient-reported outcome measures. METHODS: This paper describes a retrospective case series of patients with Ehlers–Danlos syndrome seen by the senior author between 2005 and 2019. A literature review was conducted to summarise the existing findings. RESULTS: Twenty-one patients met the inclusion criteria. All reported symptoms were grouped; this showed that swallowing, voice and hyolaryngeal skeletal complex problems were commonest. Patient-reported outcome measures were available for eight patients, which showed large variations in: the Reflux Severity Index (median = 25.5; range = 0–33), Eating Assessment Tool score (median = 21.5; range = 0–35) and Voice Handicap Index (median = 21.5; range = 0–104). Twelve studies met our literature review inclusion criteria, involving at least 91 patients with laryngological presentations of Ehlers–Danlos syndrome. CONCLUSION: Ehlers–Danlos syndrome patients experience musculoskeletal issues, which in the throat manifest as hyolaryngeal skeletal complex problems. Future studies with larger patient numbers are required to validate laryngological patient-reported outcome measure tools in Ehlers–Danlos syndrome

    Appearance and management of COVID-19 laryngo-tracheitis: two case reports.

    Get PDF
    We present two cases of coronavirus disease 2019 (COVID-19)-related laryngotracheitis in good-prognosis, ventilated patients who had failed extubation. As the pandemic continues to unfold across the globe and better management of those with respiratory failure develops, this may be an increasingly common scenario. Close ENT-intensivist liaison, meticulous team preparation, early consideration of rigid endoscopy and prospective data collection and case sharing are recommended

    Parotid haemangiomas in childhood: a case for MRI

    Get PDF
    Seven infants with unilateral parotid haemangiomas seen at one centre are presented. Their case notes and special investigations an reviewed. Magnetic resonance imaging (MRI) is revealed as the investigation of choice because of picture quality, definition of soft tissues and lack of exposure to ionizing radiation. MRI allows a definite diagnosis to be made without any invasive procedure being required. A future study following up these infants may be of interest because of controversy regarding the spontaneous resolution of these lesions

    Vertebral rotation measurement: a summary and comparison of common radiographic and CT methods

    Get PDF
    Current research has provided a more comprehensive understanding of Adolescent Idiopathic Scoliosis (AIS) as a three-dimensional spinal deformity, encompassing both lateral and rotational components. Apart from quantifying curve severity using the Cobb angle, vertebral rotation has become increasingly prominent in the study of scoliosis. It demonstrates significance in both preoperative and postoperative assessment, providing better appreciation of the impact of bracing or surgical interventions. In the past, the need for computer resources, digitizers and custom software limited studies of rotation to research performed after a patient left the scoliosis clinic. With advanced technology, however, rotation measurements are now more feasible. While numerous vertebral rotation measurement methods have been developed and tested, thorough comparisons of these are still relatively unexplored. This review discusses the advantages and disadvantages of six common measurement techniques based on technology most pertinent in clinical settings: radiography (Cobb, Nash-Moe, Perdriolle and Stokes' method) and computer tomography (CT) imaging (Aaro-Dahlborn and Ho's method). Better insight into the clinical suitability of rotation measurement methods currently available is presented, along with a discussion of critical concerns that should be addressed in future studies and development of new methods

    Measurement of vertebral rotation in adolescent idiopathic scoliosis with low-dose CT in prone position - method description and reliability analysis

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>To our knowledge there is no report in the literature on measurements of vertebral rotation with low-dose computed tomography (CT) in prone position.</p> <p>Aims</p> <p>To describe and test the reliability of this new method, compare it with other methods in use and evaluate the influence of body position on the degree of vertebral rotation measured by different radiological methods.</p> <p>Study design</p> <p>Retrospective study.</p> <p>Methods</p> <p>25 consecutive patients with adolescent idiopathic scoliosis scheduled for surgery (17 girls, 8 boys) aged 15 ± 2 years (mean ± SD) were included in the analysis of this study. The degree of the vertebral rotation was in all patients measured according to the method of Perdriolle on standing plain radiographs and on supine CT scanogram, and according to the method of Aaro and Dahlborn on axial CT images in prone position and on magnetic resonance imaging (MRI) in supine position. The measurements were done by one neuroradiologist at two different occasions. Bland and Altman statistical approach was used in the reliability assessment.</p> <p>Results</p> <p>The reliability of measuring vertebral rotation by axial CT images in prone position was almost perfect with an intraclass correlation coefficient of 0.95, a random error of the intraobserver differences of 2.3°, a repeatability coefficient of 3.2° and a coefficient of variation of 18.4%. Corresponding values for measurements on CT scanogram were 0.83, 5.1°, 7.2°, and 32.8%, respectively, indicating lower reliability of the latter modality and method. The degree of vertebral rotation measured on standing plain radiographs, prone CT scanogram, axial images on CT in prone position and on MRI in supine position were 25.7 ± 9.8°, 21.9 ± 8.3°, 17.4 ± 7.1°, and 16.1 ± 6.5°, respectively. The vertebral rotation measured on axial CT images in prone position was in average 7.5% larger than that measured on axial MRI in supine position.</p> <p>Conclusions</p> <p>This study has shown that measurements of vertebral rotation in prone position were more reliable on axial CT images than on CT scanogram. The measurement of vertebral rotation on CT (corrected to the pelvic tilt) in prone position imposes lower impact of the recumbent position on the vertebral rotation than did MRI in supine position. However, the magnitude of differences is of doubtful clinical significance.</p

    The Use of a Pressure-Indicating Sensor Film to Provide Feedback upon Hydrogel-Forming Microneedle Array Self-Application In Vivo

    Get PDF
    PURPOSE:To evaluate the combination of a pressure-indicating sensor film with hydrogel-forming microneedle arrays, as a method of feedback to confirm MN insertion in vivo.METHODS:Pilot in vitro insertion studies were conducted using a Texture Analyser to insert MN arrays, coupled with a pressure-indicating sensor film, at varying forces into excised neonatal porcine skin. In vivo studies involved twenty human volunteers, who self-applied two hydrogel-forming MN arrays, one with a pressure-indicating sensor film incorporated and one without. Optical coherence tomography was employed to measure the resulting penetration depth and colorimetric analysis to investigate the associated colour change of the pressure-indicating sensor film.RESULTS:Microneedle insertion was achieved in vitro at three different forces, demonstrating the colour change of the pressure-indicating sensor film upon application of increasing pressure. When self-applied in vivo, there was no significant difference in the microneedle penetration depth resulting from each type of array, with a mean depth of 237 ÎĽm recorded. When the pressure-indicating sensor film was present, a colour change occurred upon each application, providing evidence of insertion.CONCLUSIONS:For the first time, this study shows how the incorporation of a simple, low-cost pressure-indicating sensor film can indicate microneedle insertion in vitro and in vivo, providing visual feedback to assure the user of correct application. Such a strategy may enhance usability of a microneedle device and, hence, assist in the future translation of the technology to widespread clinical use
    • …
    corecore