1,259 research outputs found

    A comprehensive evaluation of the accuracy of CBCT and deformable registration based dose calculation in lung proton therapy

    Get PDF
    The uncertainties in water equivalent thickness (WET) and accuracy of dose estimation using a virtual CT (vCT), generated from deforming the planning CT (pCT) onto the daily cone-beam CT (CBCT), were comprehensively evaluated in the context of lung malignancies and passive scattering proton therapy. The validation methodology utilized multiple CBCT datasets to generate the vCTs of twenty lung cancer patients. A correction step was applied to the vCTs to account for anatomical modifications that could not be modeled by deformation alone. The CBCT datasets included a regular CBCT (rCBCT) and synthetic CBCTs created from the rCBCT and rescan CT (rCT), which minimized the variation in setup between the vCT and the gold-standard image (i.e., rCT). The uncertainty in WET was defined as the voxelwise difference in WET between vCT and rCT, and calculated in 3D (planning target volume, PTV) and 2D (distal and proximal surfaces). The uncertainty in WET based dose warping was defined as the difference between the warped dose and a forward dose recalculation on the rCT. The overall root mean square (RMS) uncertainty in WET was 3.6 ± 1.8, 2.2 ± 1.4 and 3.3 ± 1.8 mm for the distal surface, proximal surface and PTV, respectively. For the warped dose, the RMS uncertainty of the voxelwise dose difference was 6% ± 2% of the maximum dose (%mD), using a 20% cut-off. The rCBCT resulted in higher uncertainties due to setup variability with the rCT; the uncertainties reported with the two synthetic CBCTs were similar. The vCT followed by a correction step was found to be an accurate alternative to rCT

    Algorithm for identifying and separating beats from arterial pulse records

    Get PDF
    BACKGROUND: This project was designed as an epidemiological aid-selecting tool for a small country health center with the general objective of screening out possible coronary patients. Peripheral artery function can be non-invasively evaluated by impedance plethysmography. Changes in these vessels appear as good predictors of future coronary behavior. Impedance plethysmography detects volume variations after simple occlusive maneuvers that may show indicative modifications in arterial/venous responses. Averaging of a series of pulses is needed and this, in turn, requires proper determination of the beginning and end of each beat. Thus, the objective here is to describe an algorithm to identify and separate out beats from a plethysmographic record. A secondary objective was to compare the output given by human operators against the algorithm. METHODS: The identification algorithm detected the beat's onset and end on the basis of the maximum rising phase, the choice of possible ventricular systolic starting points considering cardiac frequency, and the adjustment of some tolerance values to optimize the behavior. Out of 800 patients in the study, 40 occlusive records (supradiastolic- subsystolic) were randomly selected without any preliminary diagnosis. Radial impedance plethysmographic pulse and standard ECG were recorded digitizing and storing the data. Cardiac frequency was estimated with the Power Density Function and, thereafter, the signal was derived twice, followed by binarization of the first derivative and rectification of the second derivative. The product of the two latter results led to a weighing signal from which the cycles' onsets and ends were established. Weighed and frequency filters are needed along with the pre-establishment of their respective tolerances. Out of the 40 records, 30 seconds strands were randomly chosen to be analyzed by the algorithm and by two operators. Sensitivity and accuracy were calculated by means of the true/false and positive/negative criteria. Synchronization ability was measured through the coefficient of variation and the median value of correlation for each patient. These parameters were assessed by means of Friedman's ANOVA and Kendall Concordance test. RESULTS: Sensitivity was 97% and 91% for the two operators, respectively, while accuracy was cero for both of them. The synchronism variability analysis was significant (p < 0.01) for the two statistics, showing that the algorithm produced the best result. CONCLUSION: The proposed algorithm showed good performance as expressed by its high sensitivity. The correlation analysis demonstrated that, from the synchronism point of view, the algorithm performed the best detection. Patients with marked arrhythmic processes are not good candidates for this kind of analysis. At most, they would be singled out by the algorithm and, thereafter, to be checked by an operator

    Assessment of a Novel VEGF Targeted Agent Using Patient-Derived Tumor Tissue Xenograft Models of Colon Carcinoma with Lymphatic and Hepatic Metastases

    Get PDF
    The lack of appropriate tumor models of primary tumors and corresponding metastases that can reliably predict for response to anticancer agents remains a major deficiency in the clinical practice of cancer therapy. It was the aim of our study to establish patient-derived tumor tissue (PDTT) xenograft models of colon carcinoma with lymphatic and hepatic metastases useful for testing of novel molecularly targeted agents. PDTT of primary colon carcinoma, lymphatic and hepatic metastases were used to create xenograft models. Hematoxylin and eosin staining, immunohistochemical staining, genome-wide gene expression analysis, pyrosequencing, qRT-PCR, and western blotting were used to determine the biological stability of the xenografts during serial transplantation compared with the original tumor tissues. Early passages of the PDTT xenograft models of primary colon carcinoma, lymphatic and hepatic metastases revealed a high degree of similarity with the original clinical tumor samples with regard to histology, immunohistochemistry, genes expression, and mutation status as well as mRNA expression. After we have ascertained that these xenografts models retained similar histopathological features and molecular signatures as the original tumors, drug sensitivities of the xenografts to a novel VEGF targeted agent, FP3 was evaluated. In this study, PDTT xenograft models of colon carcinoma with lymphatic and hepatic metastasis have been successfully established. They provide appropriate models for testing of novel molecularly targeted agents

    Design and baseline characteristics of a prospective cohort study for determinants of osteoporotic fracture in community-dwelling elderly Japanese men: the Fujiwara-kyo Osteoporosis Risk in Men (FORMEN) Study

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Osteoporosis and osteoporotic fracture in men are significant public health problems in an aging society. However, information on male osteoporosis remains impressively lacking, especially for Asians. We designed the Fujiwara-kyo Osteoporosis Risk in Men (FORMEN) study as an ancillary study of a cohort study, the Fujiwara-kyo study, to determine risk factors for osteoporotic fractures in Japanese men.</p> <p>Methods/Design</p> <p><it><b>Design</b></it>: A community-based single-centre prospective cohort study with at least a 5-year follow-up</p> <p><it><b>Subjects</b></it>: All the male participants of the Fujiwara-kyo study who were living in the four cities studied, aged 65 years and older, and able to walk without aid from others.</p> <p><it><b>Primary outcome</b></it>: Incidence of osteoporotic fractures including vertebral and clinical non-vertebral fractures.</p> <p><it><b>Additional outcomes</b></it>: Change in bone mineral density (BMD), change in hip geometry, onset of receiving benefits from Long-term Care Insurance (LCI), health-related quality of life, and mortality.</p> <p><it><b>Baseline measurements</b></it>: BMD at the lumbar spine (LS) and hip (TH), hip geometry, vertebral deformity assessment, bone turnover markers, physical and cognitive performance, various medical and lifestyle factors, and geriatric psychosocial measures confirmed by interviews based on self-administrated questionnaires.</p> <p><it><b>Outcome surveillance</b></it>: Annual mail surveys and a follow-up survey at the fifth year comprising similar items to the baseline study will be used to determine the outcomes. Receipt of benefits from LCI and mortality will be obtained from the city governments.</p> <p><it><b>Current status</b></it>: The baseline study was conducted for 2174 eligible men, and 2012 completed the study and were eligible for follow-up. Prevalence rates of osteoporosis (BMD 2.5 SD or more below the young adult mean (YAM)) and low BMD (BMD 1 SD or more below YAM) in at least one of LS and TH were calculated to be 4.4% and 41.8%, respectively. The proportion of men with low BMD only at TH showed a significant increasing trend with aging (p < 0.0001) while that only at LS showed a decreasing trend (p = 0.0386). The prevalence rate of osteoporosis was underestimated when diagnosed using only BMD at LS. Other baseline measurements were successfully obtained.</p> <p>Discussion</p> <p>FORMEN baseline study was performed as designed and the FORMEN cohort study was successfully launched.</p

    Anti-Angiogenic Activity of a Small Molecule STAT3 Inhibitor LLL12

    Get PDF
    Background: Recent data indicate the Signal Transducer and Activator of Transcription 3 (STAT3) pathway is required for VEGF production and angiogenesis in various types of cancers. STAT3 inhibitors have been shown to reduce tumor microvessel density in tumors but a direct anti-angiogenic activity has not been described. Methodology/Principal Findings: We investigated the direct action of a small molecule inhibitor of STAT3 (LLL12) in human umbilical cord vascular endothelial cells (HUVECs) in vitro, in a Matrigel model for angiogenesis in vivo, and its antitumor activity in a xenograft model of osteosarcoma. LLL12 (100 nM) significantly inhibited VEGF-stimulated STAT3 phosphorylation in HUVECs, reduced their proliferation/migration and inhibited VEGF-induced tube formation. Morphologic analysis of LLL12 treated HUVECs demonstrated marked changes in actin/tubulin distribution and bundling. In scid mice, LLL12 reduced microvessel invasion into VEGF-infused Matrigel plugs by,90 % at a dose of 5 mg/kg daily. Following a period of tumor progression (2 weeks), LLL12 completely suppressed further growth of established OS-1 osteosarcoma xenografts. Pharmacodynamic studies showed robust phosphorylated STAT3 in control tumors, whereas phospho-STAT3 was not detected in LLL12-treated OS-1 tumors. Treated tumors demonstrated decreased proliferation (Ki67 staining), and decreased microvessel density (CD34 staining), but no significant increase in apoptosis (TUNEL staining), relative to controls. Assay of angiogenic factors, using an antibody array, showed VEGF, MMP-9, Angiopoietin1/2, Tissue Factor and FGF-

    First Clinical Investigation of Cone Beam Computed Tomography and Deformable Registration for Adaptive Proton Therapy for Lung Cancer

    Get PDF
    PURPOSE: An adaptive proton therapy workflow using cone beam computed tomography (CBCT) is proposed. It consists of an online evaluation of a fast range-corrected dose distribution based on a virtual CT (vCT) scan. This can be followed by more accurate offline dose recalculation on the vCT scan, which can trigger a rescan CT (rCT) for replanning. METHODS AND MATERIALS: The workflow was tested retrospectively for 20 consecutive lung cancer patients. A diffeomorphic Morphon algorithm was used to generate the lung vCT by deforming the average planning CT onto the CBCT scan. An additional correction step was applied to account for anatomic modifications that cannot be modeled by deformation alone. A set of clinical indicators for replanning were generated according to the water equivalent thickness (WET) and dose statistics and compared with those obtained on the rCT scan. The fast dose approximation consisted of warping the initial planned dose onto the vCT scan according to the changes in WET. The potential under- and over-ranges were assessed as a variation in WET at the target's distal surface. RESULTS: The range-corrected dose from the vCT scan reproduced clinical indicators similar to those of the rCT scan. The workflow performed well under different clinical scenarios, including atelectasis, lung reinflation, and different types of tumor response. Between the vCT and rCT scans, we found a difference in the measured 95% percentile of the over-range distribution of 3.4 ± 2.7 mm. The limitations of the technique consisted of inherent uncertainties in deformable registration and the drawbacks of CBCT imaging. The correction step was adequate when gross errors occurred but could not recover subtle anatomic or density changes in tumors with complex topology. CONCLUSIONS: A proton therapy workflow based on CBCT provided clinical indicators similar to those using rCT for patients with lung cancer with considerable anatomic changes

    Factors Influencing Chinese Male's Willingness to Undergo Circumcision: A Cross-Sectional Study in Western China

    Get PDF
    BACKGROUND: Male circumcision (MC) has been shown to reduce the risk of female to male transmission of HIV. The goal of this survey was to explore the acceptability of MC among the Chinese and to identify factors associated with circumcision preference. METHODS: A cross-sectional survey was conducted between September 2009 and December 2010. We interviewed 2,219 male community participants, from three high HIV prevalence provinces in western China. A structured questionnaire was used to collect data on MC knowledge, willingness to accept MC, reasons to accept or refuse MC, and sexual behaviors and health. For those who refused MC, a health education intervention providing information on the benefits of circumcision was conducted. We used multiple logistic regression models to identify factors associated with the acceptability of MC. RESULTS: Of the respondents (n = 2,219), 44.6% (989/2,219) reported they would accept MC for the following reasons: promotion of female partners' hygiene (60.3%), redundant foreskin (59.4%), prevention of penile cancer (50.2%), enhanced sexual pleasure (41.4%), and protection against HIV and STDs (34.2%). The multivariable logistic regression showed that five factors were associated with MC willingness: long foreskin (OR = 15.98), residing in Xinjiang province (OR = 3.69), being younger than 25 (OR = 1.60), knowing hazards of redundant foreskin (OR = 1.78), and having a friend who underwent circumcision (OR = 1.36). CONCLUSION: The acceptability of male circumcision was high among the general population in China. Our study elucidates the factors associated with circumcision preference and suggests that more health education campaigns about positive health effects are necessary to increase the MC rate in China
    • …
    corecore