14 research outputs found

    [Massive pulmonary embolism treated with selective infusion of tenecteplase].

    No full text
    Massive pulmonary embolism (PE) is a cardiovascular emergency due to a substantial obstruction of the pulmonary vascular bed, resulting in rapid right heart failure with a potentially fatal outcome.We present the case of a 50-year-old woman with massive PE and recent trans-sphenoid surgery because of pituitary adenoma. An occluding embolus, arising from deep venous thrombosis of the lower limbs, was demonstrated in the right pulmonary artery with selective angiography and treated with selective loco-regional infusion of low-dose tenecteplase. To the best of our knowledge, this is the first case of selective administration of low-dose tenecteplase in the pulmonary artery with successful resolution of PE without the need for adjunctive interventional procedures

    Sirolimus-Eluting Magnesium Resorbable Scaffold Implantation in Patients with Acute Myocardial Infarction

    No full text
    To date, very little is known about the performance of a sirolimus-eluting bioresorbable magnesium scaffold (Mg-BRS) in patients with acute myocardial infarction (AMI). A multicenter cohort analysis was performed on 69 consecutive AMI subjects treated with Mg-BRS. Procedural success was obtained in all cases, and no in-hospital events were reported. At 9-month follow-up, no cardiac death, target-vessel myocardial infarction, ischemia-driven target lesion revascularization, or Mg-BRS thrombosis was reported. Although our analysis showed encouraging results, larger studies and longer-term follow-up are needed to better understand the potential benefits associated with the use of a Mg-BRS in AMI patients

    SICI-GISE Position paper on the use of the magnesium bioresorbable scaffold Magmaris in clinical practice

    No full text
    Bioresorbable scaffolds have emerged as a potential breakthrough for the treatment of coronary artery lesions. The need for drug release and plaque scaffolding is temporary, and leaving a permanent stent once the process of plaque recoil and vessel healing has ended might be superfluous or even deleterious exposing the patient to the risk of very late thrombosis, eliminating vessel reactivity, impairing non-invasive imaging and precluding possible future surgical revascularization. This long-term potential limitation of permanent bare metal stents might be overcome by using a resorbable scaffold. The metallic and antithrombotic properties makes the resorbable magnesium scaffold an appealing technology for the treatment of coronary artery lesions. Notwithstanding this, its mechanical properties substantially differ from those of conventional bare metal stents, and previous experience using polymer-based scaffolds has shown that a standardized implantation technique and optimal patient and lesion selection are key factors for a successful implantation. A panel of expert cardiologists gathered to find a consensus on the best practices for Magmaris implantation in a selected patient population and to discuss the rationale for new potential future indications

    SICI-GISE position document on the use of the Magmaris resorbable magnesium scaffold in clinical practice

    No full text
    Bioresorbable scaffolds have emerged as a potential breakthrough for the treatment of coronary artery lesions. The need for drug release and plaque scaffolding is temporary, and leaving a permanent stent once the process of plaque recoil and vessel healing has ended might be superfluous or even deleterious exposing the patient to the risk of very late thrombosis, eliminating vessel reactivity, impairing non-invasive imaging and precluding possible future surgical revascularization. This long-term potential limitation of permanent bare metal stents might be overcome by using a resorbable scaffold. The metallic and antithrombotic properties make the resorbable magnesium scaffold an appealing technology for the treatment of coronary artery lesions. Notwithstanding this, its mechanical properties substantially differ from those of conventional bare metal stents, and previous experience using polymer-based scaffolds has shown that a standardized implantation technique and optimal patient and lesion selection are key factors for a successful implantation. A panel of expert cardiologists gathered to find a consensus on the best practices for Magmaris implantation in a selected patient population and to discuss the rationale for new potential future indications

    A large, prospective, multicentre study of left main PCI using a latest-generation zotarolimus-eluting stent: the ROLEX study

    No full text
    BACKGROUND: Data on left main (LM) percutaneous coronary interventions (PCI) have mostly been obtained in studies using drug-eluting stent (DES) platforms without dedicated large-vessel devices and with limited expansion capability. AIMS: Our study aimed to investigate the safety and efficacy of LM PCI with the latest-generation Resolute Onyx DES. METHODS: ROLEX (Revascularization Of LEft main with resolute onyX) is a prospective, multicentre study (ClinicalTrials.gov: NCT03316833) enrolling patients with unprotected LM coronary artery disease and a SYNTAX score <33 undergoing PCI with the Resolute Onyx zotarolimus-eluting coronary stent, that includes dedicated extra-large vessel platforms. The primary endpoint (EP) was target lesion failure (TLF): a composite of cardiac death, target vessel myocardial infarction (TVMI) and ischaemia-driven target lesion revascularisation (ID-TLR), at 1 year. All events were adjudicated by an independent clinical event committee. An independent core lab analysed all procedural angiograms. RESULTS: A total of 450 patients (mean age 71.8 years, SYNTAX score 24.5±7.2, acute coronary syndrome in 53%) were enrolled in 26 centres. Of these, 77% of subjects underwent PCI with a single-stent and 23% with a 2-stent technique (8% double kissing [DK] crush, 6% culotte, 9% T/T and small protrusion [TAP] stenting). Intravascular imaging guidance was used in 45% (42% intravascular ultrasound [IVUS], 3% optical coherence tomography [OCT]). At 1 year, the primary EP incidence was 5.1% (cardiac death 2.7%, TVMI 2.7%, ID-TLR 2.0%). The definite/probable stent thrombosis rate was 1.1%. In a prespecified adjusted subanalysis, the primary EP incidence was significantly lower in patients undergoing IVUS/OCT-guided versus angio-guided PCI (2.0 vs 7.6%; hazard ratio [HR] 0.28, 95% confidence interval [CI]: 0.13-0.58; p<0.001). CONCLUSIONS: In this large, multicentre, prospective registry, LM PCI with the Resolute Onyx DES showed good safety and efficacy at 1 year, particularly when guided by intracoronary imaging

    Contemporary practice and technical aspects in coronary intervention with bioresorbable scaffolds: a European perspective

    No full text
    Aims: Next to patient characteristics, the lack of a standardised approach for bioresorbable vascular scaffold (BVS) implantation is perceived as a potential explanation for the heterogeneous results reported so far. To provide some guidance, we sought to find a consensus on the best practices for BVS implantation and management across a broad array of patient and lesion scenarios. Methods and results: Fourteen European centres with a high volume of BVS procedures combined their efforts in an informal collaboration. To get the most objective snapshot of different practices among the participating centres, a survey with 45 multiple choice questions was prepared and conducted. The results of the survey represented a basis for the technical advice provided in the document, whereas areas of controversy are highlighted. Conclusions: Consensus criteria for patient and lesion selection, BVS implantation and optimisation, use of intravascular imaging guidance, approach to multiple patient and lesion scenarios, and management of complications, were identified

    Excimer laser technology in percutaneous coronary interventions: Cardiovascular laser society's position paper

    No full text
    Excimer Laser Coronary Atherectomy (ELCA) is a well-established therapy that emerged for the treatment of peripheral vascular atherosclerosis in the late 1980s, at a time when catheters and materials were rudimentary and associated with the most serious complications. Refinements in catheter technology and the introduction of improved laser techniques have led to their effective use for the treatment of a wide spectrum of complex coronary lesions, such as thrombotic lesions, severe calcific lesions, non-crossable or non-expandable lesions, chronic occlusions, and stent under-expansion. The gradual introduction of high-energy strategies combined with the contrast infusion technique has enabled us to treat an increasing number of complex cases with a low rate of periprocedural complications. Currently, the use of the ELCA has also been demonstrated to be effective in acute coronary syndrome (ACS), especially in the context of large thrombotic lesions

    ImpaCt of an optimal Implantation strategy on Absorb long-term Outcomes: the CIAO Registry

    No full text
    Aim: To compare the long-term outcomes of patients implanted with Absorb bioresorbable scaffold (BRS) with optimal versus suboptimal technique. Methods and results: All patients who received an Absorb between March 2012 and January 2016 were selected from 19 Italian centers databases to assess the impact of an optimal implantation technique (CIAO criteria) on long-term device-oriented composite end-point (DOCE) - including cardiac death (CD), target-vessel myocardial infarction (TV-MI) and ischemia-driven target lesion revascularization (ID-TLR) - on its single components and on scaffold thrombosis (ScT). CIAO criteria consist of predilation (balloon/vessel ratio 1:1), correct sizing (BRS/proximal reference vessel diameter -RVD- ratio 0.8–1.2) and high-pressure postdilation with non-compliant (NC) balloon (≥20 atm for balloon/BRS ratio 1:1 or ≥16 atm for a 0.25–0.5 mm oversized balloon). Among the 1.434 patients analyzed, 464 (32.4%) fulfilled all CIAO criteria for every BRS implanted (CIAO 3 group), while 970 (67.6%) did not in at least one of the received BRS (CIAO 0-1-2 group). At 31.0 (interquartile range -IQR- 24.8–38.5) months follow-up, CIAO criteria did not impact on DOCE (8.2% vs. 8.0%, p = 0.92), ID-TLR (6.9% vs. 7.1%, p = 0.72) or ScT (1.9% vs. 1.8%, p = 0.80) in the overall population. At multivariate analysis overall BRS length (p = 0.001), severely calcified lesions (p = 0.03) and absence of CIAO criteria (CIAO 0, p = 0.005) were independent predictors of DOCE in long-term follow-up. Conclusion: Our data suggest that strict application of an optimal Absorb implantation technique doesn't improve long-term DOCE or ScT but may mitigate the worse outcome of patients with calcific lesions

    A clinical and angiographic study of the XIENCE V everolimus-eluting coronary stent system in the treatment of patients with multivessel coronary artery disease: the EXECUTIVE trial (EXecutive RCT: evaluating XIENCE V in a multi vessel disease).

    Get PDF
    Objectives This study sought to investigate the efficacy and performance of the XIENCE V everolimus-eluting stent (EES) (Abbott Vascular, Santa Clara, California) in the treatment of de novo coronary lesions in patients with 2- to 3-vessel multivessel coronary artery disease (MV-CAD). Background Drug-eluting stents (DES) have emerged as an alternative to conventional coronary artery bypass surgery in patients with MV-CAD although first-generation DES yielded inferior efficacy and safety compared with surgery. Methods Prospective, randomized (1:1), multicenter feasibility trial was designed to assess angiographic efficacy of EES compared with the TAXUS paclitaxel-eluting stent (PES) in 200 patients, and a prospective, open-label, single-arm, controlled registry was designed to analyze the clinical outcome of EES at 1-year follow-up in 400 MV-CAD patients. For the randomized trial, the primary endpoint was in-stent late loss at 9 months. For the registry, the primary endpoint was a composite of all-cause death, myocardial infarction, and ischemia-driven target vessel revascularization at 12 months. Results The primary endpoint per single lesion was significantly lower in the EES group compared with the PES group (-0.03 ± 0.49 mm vs. 0.23 ± 0.51 mm, p = 0.001). Similar results were observed when analyzing all lesions (0.05 ± 0.51 mm vs. 0.24 ± 0.50 mm, p < 0.001). Clinical outcome at 1 year yielded a composite of major adverse cardiac events of 9.2% in the single-arm registry, and 11.1% and 16.5% in the EES and PES randomized groups, respectively (p = 0.30). Conclusions The EXECUTIVE trial was a randomized pilot trial dedicated to the comparison of the efficacy of 2 different DES among patients with 2- to 3-vessel MV-CAD. The study shows lower in-stent late loss at 9 months with the EES XIENCE V compared with the PES TAXUS Libertè, and a low major adverse cardiac event rate at 1 year in patients with 2-to 3-vessel MV-CAD. (EXECUTIVE [EXecutive RCT: Evaluating XIENCE V in a Multi Vessel Disease]; NCT00531011
    corecore