244 research outputs found

    Minimal stress shielding with a Mallory-Head titanium femoral stem with proximal porous coating in total hip arthroplasty

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>As longevity of cementless femoral components enters the third decade, concerns arise with long-term effects of fixation mode on femoral bone morphology. We examined the long-term consequences on femoral remodeling following total hip arthroplasty with a porous plasma-sprayed tapered titanium stem.</p> <p>Methods</p> <p>Clinical data and radiographs were reviewed from a single center for 97 randomly selected cases implanted with the Mallory-Head Porous femoral component during primary total hip arthroplasty. Measurements were taken from preoperative and long-term follow-up radiographs averaging 14 years postoperative. Average changes in the proximal, middle and diaphyseal zones were determined.</p> <p>Results</p> <p>On anteroposterior radiographs, the proximal cortical thickness was unchanged medially and the lateral zone increased 1.3%. Middle cortical thickness increased 4.3% medially and 1.2% laterally. Distal cortical thickness increased 9.6% medially and 1.9% laterally. Using the anteroposterior radiographs, canal fill at 100 mm did not correlate with bony changes at any level (Spearman's rank correlation coefficient of -0.18, 0.05, and 0.00; p value = 0.09, 0.67, 0.97). On lateral radiographs, the proximal cortical thickness increased 1.5% medially and 0.98% laterally. Middle cortical thickness increased 2.4% medially and 1.3% laterally. Distal cortical thickness increased 3.5% medially and 2.1% laterally. From lateral radiographs, canal fill at 100 mm correlated with bony hypertrophy at the proximal, mid-level, and distal femur (Spearman's rank correlation coefficient of 0.85, 0.33, and 0.28, respectively; p value = 0.001, 0.016, and 0.01, respectively).</p> <p>Conclusion</p> <p>Stress shielding is minimized with the Mallory-Head titanium tapered femoral stem with circumferential proximal plasma-sprayed coating in well-fixed and well-functioning total hip arthroplasty. Additionally, the majority of femora demonstrated increased cortical thickness in all zones around the stem prosthesis. Level of Evidence: Therapeutic Level III.</p

    Revision total hip arthroplasty using the Zweymuller femoral stem

    Get PDF
    Background: A variety of femoral stem designs have been reported to be successful in revision total hip arthroplasty without consensus as to optimal design. We evaluated the clinical and radiographic outcomes in a consecutive series of femoral revisions using a wedge-shape, tapered-stem design at medium and long-term follow-up. Materials and methods: We performed a retrospective review of clinical and radiographic outcomes of twenty-eight consecutive femoral revisions arthroplasties, which were done using the Zweymuller femoral stem. Results: The mean follow-up was 7.4 years (range 2-15 years). No stem re-revision was necessary. All stems were judged to be stable by radiographic criteria at the most recent follow-up. The final mean Harris hip score was 90. There was no difference in Harris hip scores, implant stability, or radiological appearance (distal cortical hypertrophy or proximal stress shielding) of the implants between medium-term (mean 5.7 years) and long-term (mean 12.4 years) follow-up. Conclusions: We found the Zweymuller femoral stem design to be durable for revision hip arthroplasty when there is an intact metaphyseal-diaphyseal junction for adequate press-fit stability at surgery. © Springer-Verlag 2008

    Congenital hip dysplasia treated by total hip arthroplasty using cementless tapered stem in patients younger than 50 years old: results after 12-years follow-up

    Get PDF
    Background Congenital hip dysplasia may lead to severe acetabular and femoral abnormalities that can make total hip arthroplasty a challenging procedure. We assessed a series of patients affected by developmental hip dysplasia treated with total hip arthroplasty using cementless tapered stem and here we report the outcomes at long-term follow-up. Materials and methods Twenty-eight patients (24 women and 4 men) aged between 44 and 50 years (mean 47 years) were observed. Clinical evaluation was rated with the Harris Hip Score. Radiographic evaluation consisted in standard anteroposterior and axial view radiographs of the hip. According to Crowe’s classification, 16 hips presented dysplasia grade 1, 14 grade 2, and 4 grade 3. All patients were treated with total hip arthroplasty using a cementless tapered stem (Wagner Cone Prosthesis). Six patients were operated bilaterally, with a totally of 34 hips operated. After surgery, the patients were clinically and radiographically checked at 3, 6, and 12 months and yearly thereafter until an average follow-up of 12 years (range 10–14 years). Results Average Harris Hip Score was 56 ± 9 (range 45–69) preoperatively, 90 ± 9 (range 81–100) 12 months after surgery, and 91 ± 8 (range 83–100) at last follow-up. Radiographic evaluation demonstrated excellent osteointegration of the implants. Signs of bone resorption were present in 6 hips, nevertheless no evidence of loosening was observed and none of the implants has been revised. Conclusions Even in dysplasic femur, the tapered stem allowed adequate stability and orientation of the implant. We consider tapered stem a suitable option for total hip arthroplasty in developmental hip dysplasia, also in case of young patients, thanks to the favourable long-term results

    Adverse reactions to metal debris occur with all types of hip replacement not just metal-on-metal hips: a retrospective observational study of 3340 revisions for adverse reactions to metal debris from the National Joint Registry for England, Wales, Northern Ireland and the Isle of Man.

    Get PDF
    BACKGROUND: Adverse reactions to metal debris (ARMD) have resulted in the high short-term failure rates observed with metal-on-metal hip replacements. ARMD has recently been reported in non-metal-on-metal total hip replacements (non-MoM THRs) in a number of small cohort studies. However the true magnitude of this complication in non-MoM THRs remains unknown. We used a nationwide database to determine the risk of ARMD revision in all non-MoM THRs, and compared patient and surgical factors associated with ARMD revision between non-MoM and MoM hips. METHODS: We performed a retrospective observational study using data from the National Joint Registry for England, Wales, Northern Ireland and the Isle of Man. All primary hip replacements undergoing revision surgery for ARMD were included (n = 3,340). ARMD revision risk in non-MoM THRs was compared between different commonly implanted bearing surfaces and femoral head sizes (Chi-squared test). Differences in patient and surgical factors between non-MoM hips and MoM hips revised for ARMD were also analysed (Chi-squared test and unpaired t-test). RESULTS: Of all ARMD revisions, 7.5% (n = 249) had non-MoM bearing surfaces. The relative risk of ARMD revision was 2.35 times (95% CI 1.76-3.11) higher in ceramic-on-ceramic bearings compared with hard-on-soft bearings (0.055 vs. 0.024%; p < 0.001), and 2.80 times (95% CI 1.74-4.36) higher in 36 mm metal-on-polyethylene bearings compared to 28 mm and 32 mm metal-on-polyethylene bearings (0.058 vs. 0.021%; p < 0.001). ARMD revisions were performed earlier in non-MoM hips compared to MoM hips (mean 3.6-years vs. 5.6-years; p < 0.0001). Non-MoM hips had more abnormal findings at revision (63.1 vs. 35.7%; p < 0.001), and more intra-operative adverse events (6.4 vs. 1.6%; p < 0.001) compared to MoM hips. CONCLUSIONS: Although the overall risk of ARMD revision surgery in non-MoM THRs appears low, this risk is increasing, and is significantly higher in ceramic-on-ceramic THRs and 36 mm metal-on-polyethylene THRs. ARMD may therefore represent a significant clinical problem in non-MoM THRs
    corecore