106 research outputs found
Association between Radiologists' Experience and Accuracy in Interpreting Screening Mammograms
<p>Abstract</p> <p>Background</p> <p>Radiologists have been observed to differ, sometimes substantially, both in their interpretations of mammograms and in their recommendations for follow-up. The aim of this study was to determine how factors related to radiologists' experience affect the accuracy of mammogram readings.</p> <p>Methods</p> <p>We selected a random sample of screening mammograms from a population-based breast cancer screening program. The sample was composed of 30 women with histopathologically-confirmed breast cancer and 170 women without breast cancer after a 2-year follow-up (the proportion of cancers was oversampled). These 200 mammograms were read by 21 radiologists routinely interpreting mammograms, with different amount of experience, and by seven readers who did not routinely interpret mammograms. All readers were blinded to the results of the screening. A positive assessment was considered when a BI-RADS III, 0, IV, V was reported (additional evaluation required). Diagnostic accuracy was calculated through sensitivity and specificity.</p> <p>Results</p> <p>Average specificity was higher in radiologists routinely interpreting mammograms with regard to radiologists who did not (66% vs 56%; p < .001). Multivariate analysis based on routine readers alone showed that specificity was higher among radiologists who followed-up cases for which they recommended further workup (feedback) (OR 1.37; 95% CI 1.03 to 1.85), those spending less than 25% of the working day on breast radiology (OR 1.49; 95% CI 1.18 to 1.89), and those aged more than 45 years old (OR 1.33; 95% CI 1.12 to 1.59); the variable of average annual volume of mammograms interpreted by radiologists, classified as more or less than 5,000 mammograms per year, was not statistically significant (OR 1.06; 95% CI 0.90 to 1.25).</p> <p>Conclusion</p> <p>Among radiologists who read routinely, volume is not associated with better performance when interpreting screening mammograms, although specificity decreased in radiologists not routinely reading mammograms. Follow-up of cases for which further workup is recommended might reduce variability in mammogram readings and improve the quality of breast cancer screening programs.</p
Radiographers supporting radiologists in the interpretation of screening mammography: a viable strategy to meet the shortage in the number of radiologists.
BackgroundAn alternative approach to the traditional model of radiologists interpreting screening mammography is necessary due to the shortage of radiologists to interpret screening mammograms in many countries.MethodsWe evaluated the performance of 15 Mexican radiographers, also known as radiologic technologists, in the interpretation of screening mammography after a 6 months training period in a screening setting. Fifteen radiographers received 6 months standardized training with radiologists in the interpretation of screening mammography using the Breast Imaging Reporting and Data System (BI-RADS) system. A challenging test set of 110 cases developed by the Breast Cancer Surveillance Consortium was used to evaluate their performance. We estimated sensitivity, specificity, false positive rates, likelihood ratio of a positive test (LR+) and the area under the subject-specific Receiver Operating Characteristic (ROC) curve (AUC) for diagnostic accuracy. A mathematical model simulating the consequences in costs and performance of two hypothetical scenarios compared to the status quo in which a radiologist reads all screening mammograms was also performed.ResultsRadiographer's sensitivity was comparable to the sensitivity scores achieved by U.S. radiologists who took the test but their false-positive rate was higher. Median sensitivity was 73.3 % (Interquartile range, IQR: 46.7-86.7 %) and the median false positive rate was 49.5 % (IQR: 34.7-57.9 %). The median LR+ was 1.4 (IQR: 1.3-1.7 %) and the median AUC was 0.6 (IQR: 0.6-0.7). A scenario in which a radiographer reads all mammograms first, and a radiologist reads only those that were difficult for the radiographer, was more cost-effective than a scenario in which either the radiographer or radiologist reads all mammograms.ConclusionsGiven the comparable sensitivity achieved by Mexican radiographers and U.S. radiologists on a test set, screening mammography interpretation by radiographers appears to be a possible adjunct to radiologists in countries with shortages of radiologists. Further studies are required to assess the effectiveness of different training programs in order to obtain acceptable screening accuracy, as well as the best approaches for the use of non-physician readers to interpret screening mammography
Cross-sectional associations between multiple lifestyle behaviors and health-related quality of life in the 10,000 steps cohort
Background: The independent and combined influence of smoking, alcohol consumption, physical activity, diet, sitting time, and sleep duration and quality on health status is not routinely examined. This study investigates the relationships between these lifestyle behaviors, independently and in combination, and health-related quality of life (HRQOL). Methods: Adult members of the 10,000 Steps project (n = 159,699) were invited to participate in an online survey in November-December 2011. Participant socio-demographics, lifestyle behaviors, and HRQOL (poor self-rated health; frequent unhealthy days) were assessed by self-report. The combined influence of poor lifestyle behaviors were examined, independently and also as part of two lifestyle behavior indices, one excluding sleep quality (Index 1) and one including sleep quality (Index 2). Adjusted Cox proportional hazard models were used to examine relationships between lifestyle behaviors and HRQOL. Results: A total of 10,478 participants provided complete data for the current study. For Index 1, the Prevalence Ratio (p value) of poor self-rated health was 1.54 (p = 0.001), 2.07 (p≤0.001), 3.00 (p≤0.001), 3.61 (p≤0.001) and 3.89 (p≤0.001) for people reporting two, three, four, five and six poor lifestyle behaviors, compared to people with 0-1 poor lifestyle behaviors. For Index 2, the Prevalence Ratio (p value) of poor self-rated health was 2.26 (p = 0.007), 3.29 (p≤0.001), 4.68 (p≤0.001), 6.48 (p≤0.001), 7.91 (p≤0.001) and 8.55 (p≤0.001) for people reporting two, three, four, five, six and seven poor lifestyle behaviors, compared to people with 0-1 poor lifestyle behaviors. Associations between the combined lifestyle behavior index and frequent unhealthy days were statistically significant and similar to those observed for poor self-rated health. Conclusions: Engaging in a greater number of poor lifestyle behaviors was associated with a higher prevalence of poor HRQOL. This association was exacerbated when sleep quality was included in the index. © 2014 Duncan et al
Platelet rich plasma injection grafts for musculoskeletal injuries: a review
In Europe and the United States, there is an increasing prevalence of the use of autologous blood products to facilitate healing in a variety of applications. Recently, we have learned more about specific growth factors, which play a crucial role in the healing process. With that knowledge there is abundant enthusiasm in the application of concentrated platelets, which release a supra-maximal quantity of these growth factors to stimulate recovery in non-healing injuries. For 20 years, the application of autologous PRP has been safely used and documented in many fields including; orthopedics, sports medicine, dentistry, ENT, neurosurgery, ophthalmology, urology, wound healing, cosmetic, cardiothoracic, and maxillofacial surgery. This article introduces the reader to PRP therapy and reviews the current literature on this emerging treatment modality. In summary, PRP provides a promising alternative to surgery by promoting safe and natural healing. However, there are few controlled trials, and mostly anecdotal or case reports. Additionally the sample sizes are frequently small, limiting the generalization of the findings. Recently, there is emerging literature on the beneficial effects of PRP for chronic non-healing tendon injuries including lateral epicondylitis and plantar fasciitis and cartilage degeneration (Mishra and Pavelko, The American Journal of Sports Medicine 10(10):1–5, 2006; Barrett and Erredge, Podiatry Today 17:37–42, 2004). However, as clinical use increases, more controlled studies are needed to further understand this treatment
Genetic Interactions between the Drosophila Tumor Suppressor Gene ept and the stat92E Transcription Factor
Tumor Susceptibility Gene-101 (TSG101) promotes the endocytic degradation of transmembrane proteins and is implicated as a mutational target in cancer, yet the effect of TSG101 loss on cell proliferation in vertebrates is uncertain. By contrast, Drosophila epithelial tissues lacking the TSG101 ortholog erupted (ept) develop as enlarged undifferentiated tumors, indicating that the gene can have anti-growth properties in a simple metazoan. A full understanding of pathways deregulated by loss of Drosophila ept will aid in understanding potential links between mammalian TSG101 and growth control.We have taken a genetic approach to the identification of pathways required for excess growth of Drosophila eye-antennal imaginal discs lacking ept. We find that this phenotype is very sensitive to the genetic dose of stat92E, the transcriptional effector of the Jak-Stat signaling pathway, and that this pathway undergoes strong activation in ept mutant cells. Genetic evidence indicates that stat92E contributes to cell cycle deregulation and excess cell size phenotypes that are observed among ept mutant cells. In addition, autonomous Stat92E hyper-activation is associated with altered tissue architecture in ept tumors and an effect on expression of the apical polarity determinant crumbs.These findings identify ept as a cell-autonomous inhibitor of the Jak-Stat pathway and suggest that excess Jak-Stat signaling makes a significant contribution to proliferative and tissue architectural phenotypes that occur in ept mutant tissues
RAD50 Is Required for Efficient Initiation of Resection and Recombinational Repair at Random, γ-Induced Double-Strand Break Ends
Resection of DNA double-strand break (DSB) ends is generally considered a critical determinant in pathways of DSB repair and genome stability. Unlike for enzymatically induced site-specific DSBs, little is known about processing of random “dirty-ended” DSBs created by DNA damaging agents such as ionizing radiation. Here we present a novel system for monitoring early events in the repair of random DSBs, based on our finding that single-strand tails generated by resection at the ends of large molecules in budding yeast decreases mobility during pulsed field gel electrophoresis (PFGE). We utilized this “PFGE-shift” to follow the fate of both ends of linear molecules generated by a single random DSB in circular chromosomes. Within 10 min after γ-irradiation of G2/M arrested WT cells, there is a near-synchronous PFGE-shift of the linearized circular molecules, corresponding to resection of a few hundred bases. Resection at the radiation-induced DSBs continues so that by the time of significant repair of DSBs at 1 hr there is about 1–2 kb resection per DSB end. The PFGE-shift is comparable in WT and recombination-defective rad52 and rad51 strains but somewhat delayed in exo1 mutants. However, in rad50 and mre11 null mutants the initiation and generation of resected ends at radiation-induced DSB ends is greatly reduced in G2/M. Thus, the Rad50/Mre11/Xrs2 complex is responsible for rapid processing of most damaged ends into substrates that subsequently undergo recombinational repair. A similar requirement was found for RAD50 in asynchronously growing cells. Among the few molecules exhibiting shift in the rad50 mutant, the residual resection is consistent with resection at only one of the DSB ends. Surprisingly, within 1 hr after irradiation, double-length linear molecules are detected in the WT and rad50, but not in rad52, strains that are likely due to crossovers that are largely resection- and RAD50-independent
Relative effectiveness and adverse effects of cervical manipulation, mobilisation and the activator instrument in patients with sub-acute non-specific neck pain: results from a stopped randomised trial
<p>Abstract</p> <p>Background</p> <p>Neck pain of a mechanical nature is a common complaint seen by practitioners of manual medicine, who use a multitude of methods to treat the condition. It is not known, however, if any of these methods are superior in treatment effectiveness. This trial was stopped due to poor recruitment. The purposes of this report are (1) to describe the trial protocol, (2) to report on the data obtained from subjects who completed the study, (3) to discuss the problems we encountered in conducting this study.</p> <p>Methods</p> <p>A pragmatic randomised clinical trial was undertaken. Patients who met eligibility criteria were randomised into three groups. One group was treated using specific segmental high velocity low amplitude manipulation (diversified), another by specific segmental mobilisation, and a third group by the Activator instrument. All three groups were also treated for any myofascial distortions and given appropriate exercises and advice. Participants were treated six times over a three-week period or until they reported being pain free. The primary outcome measure for the study was Patient Global Impression of Change (PGIC); secondary outcome measures included the Short-Form Health Survey (SF-36v<sub>2</sub>), the neck Bournemouth Questionnaire, and the numerical rating scale for pain intensity. Participants also kept a diary of any pain medication taken and noted any perceived adverse effects of treatment. Outcomes were measured at four points: end of treatment, and 3, 6, and 12 months thereafter.</p> <p>Results</p> <p>Between January 2007 and March 2008, 123 patients were assessed for eligibility, of these 47 were considered eligible, of which 16 were allocated to manipulation, 16 to the Activator instrument and 15 to the mobilisation group. Comparison between the groups on the PGIC adjusted for baseline covariants did not show a significant difference for any of the endpoints. Within group analyses for change from baseline to the 12-month follow up for secondary outcomes were significant for all groups on the Bournemouth Questionnaire and for pain, while the mobilisation group had a significant improvement on the PCS and MCS subscales of the SF-36<sub>v2</sub>. Finally, there were no moderate, severe, or long-lasting adverse effects reported by any participant in any group.</p> <p>Conclusions</p> <p>Although the small sample size must be taken into consideration, it appears that all three methods of treating mechanical neck pain had a long-term benefit for subacute neck pain, without moderate or serious adverse events associated with any of the treatment methods. There were difficulties in recruiting subjects to this trial. This pragmatic trial should be repeated with a larger sample size.</p
Recommended from our members
Recommendations for the definition of clinical responder in insulin preservation studies
Clinical responder studies should contribute to the translation of effective treatments and interventions to the clinic. Since ultimately this translation will involve regulatory approval, we recommend that clinical trials prespecify a responder definitio
- …