491 research outputs found

    Book review

    Get PDF

    Exhaled nitric oxide measurements in the first 2 years of life: methodological issues, clinical and epidemiological applications

    Get PDF
    Fractional exhaled nitric oxide (FeNO) is a useful tool to diagnose and monitor eosinophilic bronchial inflammation in asthmatic children and adults. In children younger than 2 years of age FeNO has been successfully measured both with the tidal breathing and with the single breath techniques. However, there are a number of methodological issues that need to be addressed in order to increase the reproducibility of the FeNO measurements within and between infants. Indeed, a standardized method to measure FeNO in the first 2 years of life would be extremely useful in order to meaningfully interpret FeNO values in this age group. Several factors related to the measurement conditions have been found to influence FeNO, such as expiratory flow, ambient NO and nasal contamination. Furthermore, the exposure to pre- and postnatal risk factors for respiratory morbidity has been shown to influence FeNO values. Therefore, these factors should always be assessed and their association with FeNO values in the specific study population should be evaluated and, eventually, controlled for

    Prostanoids in bronchoalveolar lavage fluid do not predict outcome in congenital diaphragmatic hernia patients

    Get PDF
    Vasoactive prostanoids may be involved in persistent pulmonary hypertension (PPH) in infants with a congenital diaphragmatic hernia (CDH). We hypothesized that increased levels of prostanoids in bronchoalveolar lavage (BAL) fluid would predict clinical outcome. We measured the concentrations of 6-keto-prostaglandin F1α (6-keto-PGF1α), thromboxane B2 (TxB2), protein, albumin, total cell count, and elastase-α1-proteinase-inhibitor complex in BAL fluid of 18 CDH patients and of 13 control subjects without PPH. We found different concentrations of prostanoids in BAL fluid of CDH patients with PPH: infants with a poor prognosis had either high levels of both 6-keto-PGF1α and TxB2 compared to controls, or high levels of 6-keto-PGF1α only. TxB2 levels showed a large variability in all CDH patients irrespective of outcome. We conclude that prostanoid levels in BAL fluid do not predict clinical outcome in CDH patients

    Brand and generic use of inhalation medication and frequency of switching in children and adults : a population-based cohort study

    Get PDF
    BACKGROUND: The expiration of patents of brand inhalation medications and the ongoing pressure on healthcare budgets resulted in a growing market for generics. AIM: To study the use of brand and generic inhalation medication and the frequency of switching between brand and generic and between devices. In addition, we investigated whether switching affected adherence. METHODS: From dispensing data from the Dutch PHARMO Database Network a cohort aged ≥ 5 years, using ≥ 1 year of inhalation medication between 2003 and 2012 was selected. Switching was defined as changing from brand to generic or vice versa. In addition, we studied change in aerosol delivery device type (e.g., DPI, pMDI, and nebulizers). Adherence was calculated using the medication possession ratio (MPR). RESULTS: The total cohort comprised 70,053 patients with 1,604,488 dispensations. Per calendar year, 5% switched between brand and generic inhalation medication and 5% switched between devices. Median MPRs over the first 12 months ranged between 33 and 55%. Median MPR over the total period was lower after switch from brand to generic and vice versa for formoterol (44.5 vs. 42.1 and 63.5 vs. 53.8) and beclomethasone (93.8 vs. 59.8 and 81.3 vs. 55.9). CONCLUSION: Per year, switching between brand and generic inhalation medication was limited to 5% of the patients, switching between device types was observed in 5% as well. Adherence to both generic and brand inhalation medication was low. Effect of switching on adherence was contradictory; depending on time period, medication and type, and direction of switching. Further research on reasons for switching and potential impact on clinical outcomes is warranted

    Exhaled nitric oxide in mylar balloons: influence of storage time, humidity and temperature.

    Get PDF
    BACKGROUND: Mylar balloons are used to collect exhaled air for analysis of fractional nitric oxide concentration (FENO). AIM: We studied the effect of storage conditions on the stability of nitric oxide (NO) in mylar balloons. METHODS: Exhaled air samples and calibration gases were stored in mylar balloons at 4, 21 and 37 degrees C, with or without silica gel. NO was measured after 0, 6, 9, 24 and 48 h. Scheffe F-tests were used to compare NO values. RESULTS: NO remained stable in balloons for 9 h at all temperatures, without silica gel. NO increased between 9 and 48 h, but only with low initial FENO. Silica gel increased variability. CONCLUSIONS: FENO in mylar balloons is stable for at least 9 h. The storage temperature is not critical, but silica gel increases variability

    Is there an association between wheezing and constipation in preschool children? Explanations from a longitudinal birth cohort

    Get PDF
    Objective: To assess whether wheezing and atopic dermatitis were associated with constipation in preschool children and to what extent shared risk factors contribute to this relationship. Methods: A population-based sample of 4651 preschool children was used. At the age of 24, 36 and 48 months, a parental report of functional constipation was available according to the Rome II criteria, and data on atopic dermatitis and wheezing were available using age-adapted questionnaires from the International Study of Asthma and Allergie

    Hydrogen peroxide in breath condensate during a common cold.

    Get PDF
    BACKGROUND: Hydrogen peroxide (H2O2) in exhaled air condensate is elevated in inflammatory disorders of the lower respiratory tract. It is unknown whether viral colds contribute to exhaled H2O2. AIM: To assess exhaled H2O2 during and after a common cold. METHODS: We examined H2O2 in the breath condensate of 20 normal subjects with acute symptoms of a common cold and after recovery 2 weeks later and, similarly, in 10 subjects without infection. H2O2 was measured with a fluorimetric assay. RESULTS: At the time of infection exhaled H2O2 (median, ranges) was 0.20 microM (0.03-1.2 microM), and this decreased to 0.09 microM (< 0.01-0.40 microM) after recovery (p = 0.006). There was no significant difference in lung function (forced vital capacity and forced expiratory volume in 1 sec) during and after colds. In the controls, exhaled H2O2 did not change over a 2-week period. CONCLUSIONS: H2O2 in exhaled air condensate is elevated during a common cold, and returns to normal within 2 weeks of recovery in healthy subjects. Hence, symptomatic upper respiratory tract infection may act as a confounder in studies of H2O2 as a marker of chronic lower airway inflammation

    Lung eicosanoids in perinatal rats with congenital diaphragmatic hernia

    Get PDF
    Abnormal levels of pulmonary eicosanoids have been reported in infants with persistent pulmonary hypertension (PPH) and congenital diaphragmatic hernia (CDH). We hypothesized that a dysbalance of vasoconstrictive and vasodilatory eicosanoids is involved in PPH in CDH patients. The levels of several eicosanoids in lung homogenates and in bronchoalveolar lavage fluid of controls and rats with CDH were measured after caesarean section or spontaneous birth. In controls the concentration of the stable metabolite of prostacyclin (6-keto-PGF1α), thromboxane A2 (TxB2), prostaglandin E2 (PGE2), and leukotriene B4 (LTB4) decreased after spontaneous birth. CDH pups showed respiratory insufficiency directly after birth. Their lungs had higher levels of 6- keto-PGF1α, reflecting the pulmonary vasodilator prostacyclin (PGI2), than those of controls. We conclude that in CDH abnormal lung eicosanoid levels are present perinatally. The elevated levels of 6-keto-PGF1α in CDH may reflect a compensation mechanism for increased vascular resistance
    corecore