30 research outputs found

    Povećanje oslobađanja gliklazida iz smjesa dobivenih geometrijskim miješanjem

    Get PDF
    The poorly water soluble antidiabetic drug gliclazide was selected to study the effect of excipients on dissolution rate enhancement. Ordered mixtures of micronized gliclazide with lactose, mannitol, sorbitol, maltitol and sodium chloride were prepared by manual shaking of glass vials containing the drug and excipient(s). Different water soluble excipients, addition of surfactant and superdisintegrant, drug concentration and carrier particle size influenced the dissolution rate of the drug. Dissolution rate studies of the prepared ordered mixtures revealed an increase in drug dissolution with all water soluble excipients. The order of dissolution rate improvement for gliclazide was mannitol > lactose > maltitol > sorbitol > sodium chloride. Composite granules of the particle size range 355-710 µm were superior in increasing the drug dissolution rate from ordered mixtures. Reducing the carrier particle size decreased the dissolution rate of the drug, as well as the increase in drug concentration. Kinetic modeling of drug release data fitted best the Hixson-Crowell model, which indicates that all the ordered mixture formulations followed the cube root law fairly well.Teško topljivi antidijabetik gliklazid izabran je za proučavanje utjecaja pomoćnih tvari na povećanje oslobađanja. Homogene smjese mikroniziranog gliklazida s laktozom, manitolom, sorbitolom, maltitolom i natrijevim kloridom pripravljene su ručnim tresenjem staklenih bočica s lijekom i pomoćnom tvari/tvarima. Na oslobađanje lijeka utjecali su vrsta vodotopljivog ekscipijensa, dodatak surfaktanta i superdezintegratora, udio lijeka i veličina čestica punila. Sve vodotopljive pomoćne tvari povećavale su oslobađanje ljekovite tvari i to sljedećim redom: manitol > laktoza > maltitol > sorbitol > natrijev klorid. Najbolje oslobađanje lijeka bilo je iz kompozitnih granula veličine 355 do 710 µm. Iz smjesa s manjom veličinom čestica punila i većim udjelom lijeka oslobađanje lijeka bilo je manje. Kinetičko modeliranje oslobađanja najbolje je odgovaralo Hixson-Crowellovom modelu, što ukazuje na to da sve formulacije prilično dobro slijede zakon trećeg korijena

    Prediction of underlying atrial fibrillation in patients with a cryptogenic stroke: results from the NOR-FIB Study

    Get PDF
    Background - Atrial fibrillation (AF) detection and treatment are key elements to reduce recurrence risk in cryptogenic stroke (CS) with underlying arrhythmia. The purpose of the present study was to assess the predictors of AF in CS and the utility of existing AF-predicting scores in The Nordic Atrial Fibrillation and Stroke (NOR-FIB) Study. Method - The NOR-FIB study was an international prospective observational multicenter study designed to detect and quantify AF in CS and cryptogenic transient ischaemic attack (TIA) patients monitored by the insertable cardiac monitor (ICM), and to identify AF-predicting biomarkers. The utility of the following AF-predicting scores was tested: AS5F, Brown ESUS-AF, CHA2DS2-VASc, CHASE-LESS, HATCH, HAVOC, STAF and SURF. Results - In univariate analyses increasing age, hypertension, left ventricle hypertrophy, dyslipidaemia, antiarrhythmic drugs usage, valvular heart disease, and neuroimaging findings of stroke due to intracranial vessel occlusions and previous ischemic lesions were associated with a higher likelihood of detected AF. In multivariate analysis, age was the only independent predictor of AF. All the AF-predicting scores showed significantly higher score levels for AF than non-AF patients. The STAF and the SURF scores provided the highest sensitivity and negative predictive values, while the AS5F and SURF reached an area under the receiver operating curve (AUC) > 0.7. Conclusion - Clinical risk scores may guide a personalized evaluation approach in CS patients. Increasing awareness of the usage of available AF-predicting scores may optimize the arrhythmia detection pathway in stroke units

    Safety and efficacy of tenecteplase in patients with wake-up stroke assessed by non-contrast CT (TWIST): a multicentre, open-label, randomised controlled trial

    Get PDF
    Background: Current evidence supports the use of intravenous thrombolysis with alteplase in patients with wake-up stroke selected with MRI or perfusion imaging and is recommended in clinical guidelines. However, access to advanced imaging techniques is often scarce. We aimed to determine whether thrombolytic treatment with intravenous tenecteplase given within 4·5 h of awakening improves functional outcome in patients with ischaemic wake-up stroke selected using non-contrast CT. Methods: TWIST was an investigator-initiated, multicentre, open-label, randomised controlled trial with blinded endpoint assessment, conducted at 77 hospitals in ten countries. We included patients aged 18 years or older with acute ischaemic stroke symptoms upon awakening, limb weakness, a National Institutes of Health Stroke Scale (NIHSS) score of 3 or higher or aphasia, a non-contrast CT examination of the head, and the ability to receive tenecteplase within 4·5 h of awakening. Patients were randomly assigned (1:1) to either a single intravenous bolus of tenecteplase 0·25 mg per kg of bodyweight (maximum 25 mg) or control (no thrombolysis) using a central, web-based, computer-generated randomisation schedule. Trained research personnel, who conducted telephone interviews at 90 days (follow-up), were masked to treatment allocation. Clinical assessments were performed on day 1 (at baseline) and day 7 of hospital admission (or at discharge, whichever occurred first). The primary outcome was functional outcome assessed by the modified Rankin Scale (mRS) at 90 days and analysed using ordinal logistic regression in the intention-to-treat population. This trial is registered with EudraCT (2014–000096–80), ClinicalTrials.gov (NCT03181360), and ISRCTN (10601890). Findings: From June 12, 2017, to Sept 30, 2021, 578 of the required 600 patients were enrolled (288 randomly assigned to the tenecteplase group and 290 to the control group [intention-to-treat population]). The median age of participants was 73·7 years (IQR 65·9–81·1). 332 (57%) of 578 participants were male and 246 (43%) were female. Treatment with tenecteplase was not associated with better functional outcome, according to mRS score at 90 days (adjusted OR 1·18, 95% CI 0·88–1·58; p=0·27). Mortality at 90 days did not significantly differ between treatment groups (28 [10%] patients in the tenecteplase group and 23 [8%] in the control group; adjusted HR 1·29, 95% CI 0·74–2·26; p=0·37). Symptomatic intracranial haemorrhage occurred in six (2%) patients in the tenecteplase group versus three (1%) in the control group (adjusted OR 2·17, 95% CI 0·53–8·87; p=0·28), whereas any intracranial haemorrhage occurred in 33 (11%) versus 30 (10%) patients (adjusted OR 1·14, 0·67–1·94; p=0·64). Interpretation: In patients with wake-up stroke selected with non-contrast CT, treatment with tenecteplase was not associated with better functional outcome at 90 days. The number of symptomatic haemorrhages and any intracranial haemorrhages in both treatment groups was similar to findings from previous trials of wake-up stroke patients selected using advanced imaging. Current evidence does not support treatment with tenecteplase in patients selected with non-contrast CT. Funding: Norwegian Clinical Research Therapy in the Specialist Health Services Programme, the Swiss Heart Foundation, the British Heart Foundation, and the Norwegian National Association for Public Health

    Structural studies of metal ligand complexes by ion mobility-mass spectrometry

    Get PDF
    The final publication is available at Springer via http://dx.doi.org/10.1007/s12127-013-0122-8Collision cross sections (CCS) have been measured for three salen ligands, and their complexes with copper and zinc using travelling-wave ion mobility-mass spectrometry (TWIMS) and drift tube ion mobility-mass spectrometry (DTIMS), allowing a comparative size evaluation of the ligands and complexes. CCS measurements using TWIMS were determined using peptide and TAAH calibration standards. TWIMS measurements gave significantly larger CCS than DTIMS in helium, by 9 % for TAAH standards and 3 % for peptide standards, indicating that the choice of calibration standards is important in ensuring the accuracy of TWIMS-derived CCS measurements. Repeatability data for TWIMS was obtained for inter- and intra-day studies with mean RSDs of 1. 1 % and 0. 7 %, respectively. The CCS data obtained from IM-MS measurements are compared to CCS values obtained via the projection approximation, the exact hard spheres method and the trajectory method from X-ray coordinates and modelled structures using density functional theory (DFT) based methods. © 2013 Springer-Verlag Berlin Heidelberg

    Atrial fibrillation in cryptogenic stroke and TIA patients in the nordic atrial fibrillation and stroke The Nordic Atrial Fibrillation and Stroke (NOR-FIB) Study : Main results

    No full text
    Introduction: Secondary stroke prevention depends on proper identification of the underlying etiology and initiation of optimal treatment after the index event. The aim of the NOR-FIB study was to detect and quantify underlying atrial fibrillation (AF) in patients with cryptogenic stroke (CS) or transient ischaemic attack (TIA) using insertable cardiac monitor (ICM), to optimise secondary prevention, and to test the feasibility of ICM usage for stroke physicians. Patients and methods: Prospective observational international multicenter real-life study of CS and TIA patients monitored for 12 months with ICM (Reveal LINQ) for AF detection. Results: ICM insertion was performed in 91.5% by stroke physicians, within median 9 days after index event. Paroxysmal AF was diagnosed in 74 out of 259 patients (28.6%), detected early after ICM insertion (mean 48 ± 52 days) in 86.5% of patients. AF patients were older (72.6 vs 62.2; p < 0.001), had higher pre-stroke CHA₂DS₂-VASc score (median 3 vs 2; p < 0.001) and admission NIHSS (median 2 vs 1; p = 0.001); and more often hypertension (p = 0.045) and dyslipidaemia (p = 0.005) than non-AF patients. The arrhythmia was recurrent in 91.9% and asymptomatic in 93.2%. At 12-month follow-up anticoagulants usage was 97.3%. Discussion and conclusions: ICM was an effective tool for diagnosing underlying AF, capturing AF in 29% of the CS and TIA patients. AF was asymptomatic in most cases and would mainly have gone undiagnosed without ICM. The insertion and use of ICM was feasible for stroke physicians in stroke units

    Underlying causes of cryptogenic stroke and TIA in The Nordic Atrial Fibrillation and Stroke (NOR-FIB) Study – the importance of comprehensive clinical evaluation

    No full text
    Abstract Background Cryptogenic stroke is a heterogeneous condition, with a wide spectrum of possible underlying causes for which the optimal secondary prevention may differ substantially. Attempting a correct etiological diagnosis to reduce the stroke recurrence should be the fundamental goal of modern stroke management. Methods Prospective observational international multicenter study of cryptogenic stroke and cryptogenic transient ischemic attack (TIA) patients clinically monitored for 12 months to assign the underlying etiology. For atrial fibrillation (AF) detection continuous cardiac rhythm monitoring with insertable cardiac monitor (Reveal LINQ, Medtronic) was performed. The 12-month follow-up data for 250 of 259 initially included NOR-FIB patients were available for analysis. Results After 12 months follow-up probable stroke causes were revealed in 43% patients, while 57% still remained cryptogenic. AF and atrial flutter was most prevalent (29%). In 14% patients other possible causes were revealed (small vessel disease, large-artery atherosclerosis, hypercoagulable states, other cardioembolism). Patients remaining cryptogenic were younger (p < 0.001), had lower CHA2DS2-VASc score (p < 0.001) on admission, and lower NIHSS score (p = 0.031) and mRS (p = 0.016) at discharge. Smoking was more prevalent in patients that were still cryptogenic (p = 0.014), while dyslipidaemia was less prevalent (p = 0.044). Stroke recurrence rate was higher in the cryptogenic group compared to the group where the etiology was revealed, 7.7% vs. 2.8%, (p = 0.091). Conclusion Cryptogenic stroke often indicates the inability to identify the cause in the acute phase and should be considered as a working diagnosis until efforts of diagnostic work up succeed in identifying a specific underlying etiology. Timeframe of 6-12-month follow-up may be considered as optimal. Trial registration ClinicalTrials.gov Identifier NCT02937077, EudraCT 2018-002298-23
    corecore