231 research outputs found

    Density Functional Theory for the Photoionization Dynamics of Uracil

    Full text link
    Photoionization dynamics of the RNA base Uracil is studied in the framework of Density Functional Theory (DFT). The photoionization calculations take advantage of a newly developed parallel version of a multicentric approach to the calculation of the electronic continuum spectrum which uses a set of B-spline radial basis functions and a Kohn-Sham density functional hamiltonian. Both valence and core ionizations are considered. Scattering resonances in selected single-particle ionization channels are classified by the symmetry of the resonant state and the peak energy position in the photoelectron kinetic energy scale; the present results highlight once more the site specificity of core ionization processes. We further suggest that the resonant structures previously characterized in low-energy electron collision experiments are partly shifted below threshold by the photoionization processes. A critical evaluation of the theoretical results providing a guide for future experimental work on similar biosystems

    First-principles study of electron transport through C20C_{20} cages

    Full text link
    Electron transport properties of C20_{20} molecules suspended between gold electrodes are investigated using first-principles calculations. Our study reveals that the conductances are quite sensitive to the number of C20_{20} molecules between electrodes: the conductances of C20_{20} monomers are near 1 G0_{0}, while those of dimers are markedly smaller, since incident electrons easily pass the C20_{20} molecules and are predominantly scattered at the C20_{20}-C20_{20} junctions. Moreover, we find both channel currents locally circulating the outermost carbon atoms.Comment: 8 pages and 3 figure

    Correction of hypovitaminosis D improved global longitudinal strain earlier than left ventricular ejection fraction in cardiovascular older adults after orthopaedic surgery

    Get PDF
    Background Cardiovascular diseases and insufficient levels of vitamin D are risk factors for adverse surgical outcomes, and they are both commonly present among older adults undergoing orthopaedic surgery. Giving the cardiovascular effects of vitamin D, pre-operative diagnosis of hypovitaminosis D would be a valuable step for the implementation of supplementation protocols. We investigated if the normalization of serum 25 [OH] D could ameliorate cardiac performance of older adults suffering from cardiovascular diseases. Methods We enrolled 47 older adults scheduled for major orthopaedic surgery and suffering from hypovitaminosis D. Patients underwent 6-months calcifediol supplementation with a starting dose at first post-operative day of 50 \u3bcg/die in liquid preparation. Down-Titration to 20 \u3bcg/die at 3-months assessment was planned. Cardiac performance was evaluated by measuring left ventricular ejection fraction (LVEF) and global longitudinal strain (GLS) during pre-operative assessments and at 1-month, 3-months, 6-months follow-ups. Results Six months of calcifediol supplementation were associated with a significant improvement of both LVEF (+ 3.94%; 95% CI: -4.0789 to -0.8232; P < 0.01) and GLS (+ 18.56%; Z = -5.895; P < 0.0001). Conclusions Calcifediol supplementation normalized serum 25 [OH] D concentration after 1-month treatment. GLS offered better insights into myocardial contractile amelioration than LVEF, thus being useful for detecting earlier subclinical changes that may anticipate hemodynamic modifications

    Double strand breaks in DNA resulting from double-electron-emission events

    Full text link
    A mechanism of double strand breaking (DSB) in DNA due to the action of two electrons is considered. These are the electrons produced in the vicinity of DNA molecules due to ionization of water molecules with a consecutive emission of two electrons, making such a mechanism possible. This effect qualitatively solves a puzzle of large yields of DSBs following irradiation of DNA molecules. The transport of secondary electrons, including the additional electrons, is studied in relation to the assessment of radiation damage due to incident ions. This work is a stage in the inclusion of Auger mechanism and like effects into the multiscale approach to ion-beam cancer therapy.Comment: 4 pages, 3 figure

    An objective spinal motion imaging assessment (OSMIA): reliability, accuracy and exposure data

    Get PDF
    BACKGROUND: Minimally-invasive measurement of continuous inter-vertebral motion in clinical settings is difficult to achieve. This paper describes the reliability, validity and radiation exposure levels in a new Objective Spinal Motion Imaging Assessment system (OSMIA) based on low-dose fluoroscopy and image processing. METHODS: Fluoroscopic sequences in coronal and sagittal planes were obtained from 2 calibration models using dry lumbar vertebrae, plus the lumbar spines of 30 asymptomatic volunteers. Calibration model 1 (mobile) was screened upright, in 7 inter-vertebral positions. The volunteers and calibration model 2 (fixed) were screened on a motorised table comprising 2 horizontal sections, one of which moved through 80 degrees. Model 2 was screened during motion 5 times and the L2-S1 levels of the volunteers twice. Images were digitised at 5fps. Inter-vertebral motion from model 1 was compared to its pre-settings to investigate accuracy. For volunteers and model 2, the first digitised image in each sequence was marked with templates. Vertebrae were tracked throughout the motion using automated frame-to-frame registration. For each frame, vertebral angles were subtracted giving inter-vertebral motion graphs. Volunteer data were acquired twice on the same day and analysed by two blinded observers. The root-mean-square (RMS) differences between paired data were used as the measure of reliability. RESULTS: RMS difference between reference and computed inter-vertebral angles in model 1 was 0.32 degrees for side-bending and 0.52 degrees for flexion-extension. For model 2, X-ray positioning contributed more to the variance of range measurement than did automated registration. For volunteer image sequences, RMS inter-observer variation in intervertebral motion range in the coronal plane was 1.86 degreesand intra-subject biological variation was between 2.75 degrees and 2.91 degrees. RMS inter-observer variation in the sagittal plane was 1.94 degrees. Radiation dosages in each view were below the levels recommended for a plain film. CONCLUSION: OSMIA can measure inter-vertebral angular motion patterns in routine clinical settings if modern image intensifier systems are used. It requires skilful radiography to achieve optimal positioning and dose limitation. Reliability in individual subjects can be judged from the variance of their averaged inter-vertebral angles and by observing automated image registration

    Lumbar segmental mobility disorders: comparison of two methods of defining abnormal displacement kinematics in a cohort of patients with non-specific mechanical low back pain

    Get PDF
    BACKGROUND: Lumbar segmental rigidity (LSR) and lumbar segmental instability (LSI) are believed to be associated with low back pain (LBP), and identification of these disorders is believed to be useful for directing intervention choices. Previous studies have focussed on lumbar segmental rotation and translation, but have used widely varying methodologies. Cut-off points for the diagnosis of LSR & LSI are largely arbitrary. Prevalence of these lumbar segmental mobility disorders (LSMDs) in a non-surgical, primary care LBP population has not been established. METHODS: A cohort of 138 consecutive patients with recurrent or chronic low back pain (RCLBP) were recruited in this prospective, pragmatic, multi-centre study. Consenting patients completed pain and disability rating instruments, and were referred for flexion-extension radiographs. Sagittal angular rotation and sagittal translation of each lumbar spinal motion segment was measured from the radiographs, and compared to a reference range derived from a study of 30 asymptomatic volunteers. In order to define reference intervals for normal motion, and define LSR and LSI, we approached the kinematic data using two different models. The first model used a conventional Gaussian definition, with motion beyond two standard deviations (2sd) from the reference mean at each segment considered diagnostic of rotational LSMD and translational LSMD. The second model used a novel normalised within-subjects approach, based on mean normalised contribution-to-total-lumbar-motion. An LSMD was then defined as present in any segment that contributed motion beyond 2sd from the reference mean contribution-to-normalised-total-lumbar-motion. We described reference intervals for normal segmental mobility, prevalence of LSMDs under each model, and the association of LSMDs with pain and disability. RESULTS: With the exception of the conventional Gaussian definition of rotational LSI, LSMDs were found in statistically significant prevalences in patients with RCLBP. Prevalences at both the segmental and patient level were generally higher using the normalised within-subjects model (2.8 to 16.8% of segments; 23.3 to 35.5% of individuals) compared to the conventional Gaussian model (0 to 15.8%; 4.7 to 19.6%). LSMDs are associated with presence of LBP, however LSMDs do not appear to be strongly associated with higher levels of pain or disability compared to other forms of non-specific LBP. CONCLUSION: LSMDs are a valid means of defining sub-groups within non-specific LBP, in a conservative care population of patients with RCLBP. Prevalence was higher using the normalised within-subjects contribution-to-total-lumbar-motion approach
    • 

    corecore