Energy Conversion Alternatives Study (ECAS), General Electric Phase 1. Volume 2: Advanced energy conversion systems. Part 1: Open-cycle gas turbines
Ten energy conversion systems are defined and analyzed in terms of efficiency. These include: open-cycle gas turbine recuperative; open-cycle gas turbine; closed-cycle gas turbine; supercritical CO2 cycle; advanced steam cycle; liquid metal topping cycle; open-cycle MHD; closed-cycle inert gas MHD; closed-cycle liquid metal MHD; and fuel cells. Results are presented
Energy Conversion Alternatives Study (ECAS), General Electric Phase 1. Volume 2: Advanced Energy Conversion Systems. Part 2: Closed Turbine Cycles
For abstract, see N76-23680
Energy Conversion Alternatives Study (ECAS), General Electric Phase 1. Volume 1: Executive summary
A data base for the comparison of advanced energy conversion systems for utility applications using coal or coal-derived fuels was developed. Estimates of power plant performance (efficiency), capital cost, cost of electricity, natural resource requirements, and environmental intrusion characteristics were made for ten advanced conversion systems. Emphasis was on the energy conversion system in the context of a base loaded utility power plant. All power plant concepts were premised on meeting emission standard requirements. A steam power plant (3500 psig, 1000 F) with a conventional coal-burning furnace-boiler was analyzed as a basis for comparison. Combined cycle gas/steam turbine system results indicated competitive efficiency and a lower cost of electricity compared to the reference steam plant. The Open-Cycle MHD system results indicated the potential for significantly higher efficiency than the reference steam plant but with a higher cost of electricity
Energy Conversion Alternatives Study (ECAS), General Electric Phase 1. Volume 3: Energy Conversion subsystems and components. Part 2: Primary heat input systems and heat exchangers
Primary heat input systems and heat exchangers were evaluated for advanced energy conversion systems. Results are presented and discussed
Energy Conversion Alternatives Study (ECAS), General Electric Phase 1. Volume 2: Advanced energy conversion systems. Part 3: Direct energy conversion cycles
For abstract, see N76-23680
Subacute herpes simplex virus type 1 encephalitis as an initial presentation of chronic lymphocytic leukemia and multiple sclerosis: a case report
<p>Abstract</p> <p>Introduction</p> <p>Herpes simplex virus type 1 encephalitis presents acutely in patients who are immunocompetent. We report what we believe to be the first published case of a subacute course of herpes simplex virus type 1 encephalitis in a patient with asymptomatic chronic lymphocytic leukemia who subsequently developed multiple sclerosis.</p> <p>Case presentation</p> <p>A 49-year-old Caucasian woman with a history of fever blisters presented to the emergency department with a history of left temporal headache for four weeks, and numbness of the left face and leg for two weeks. A complete blood count revealed white blood cell count of 11,820 cells/mL, with an absolute lymphocyte count of 7304 cells/mL. The cerebrospinal fluid contained 6 white blood cells/μL, 63 red blood cells/μL, 54 mg glucose/dL, and 49 mg total protein/dL. Magnetic resonance imaging of the brain revealed meningoencephalitis and bilateral ventriculitis. Cerebrospinal fluid polymerase chain reaction for herpes simplex virus type 1 was positive, and the patient's symptoms resolved after ten days of treatment with parenteral aciclovir. Incidental findings on peripheral blood smear and flow cytometry testing confirmed chronic lymphocytic leukemia. One month later, she developed bilateral numbness of the hands and feet; a repeat cerebrospinal fluid polymerase chain reaction for herpes simplex virus type 1 at this time was negative. A repeat magnetic resonance imaging scan showed an expansion of the peri-ventricular lesions, and the cerebrospinal fluid contained elevated oligoclonal bands and myelin basic protein. A brain biopsy revealed gliosis consistent with multiple sclerosis, and the patient responded to treatment with high-dose parenteral steroids.</p> <p>Conclusion</p> <p>Herpes simplex virus type 1 encephalitis is a rare presentation of chronic lymphocytic leukemia. Our patient had an atypical, subacute course, presumably due to immunosuppression from chronic lymphocytic leukemia. This unusual case of herpes simplex virus type 1 encephalitis emphasizes the importance of T cell function in diseases of immune dysregulation and autoimmunity such as chronic lymphocytic leukemia and multiple sclerosis. It raises the question of whether atypical presentations of herpes simplex virus encephalitis warrant deliberations on immunocompetence. The development of multiple sclerosis in our patient so soon after she received treatment for herpes simplex virus type 1 encephalitis raises the possibility that herpes simplex virus type 1 encephalitis in an immunosuppressed patient may trigger multiple sclerosis.</p
Energy Conversion Alternatives Study (ECAS), General Electric Phase 1. Volume 3: Energy conversion subsystems and components. Part 3: Gasification, process fuels, and balance of plant
Results are presented of an investigation of gasification and clean fuels from coal. Factors discussed include: coal and coal transportation costs; clean liquid and gas fuel process efficiencies and costs; and cost, performance, and environmental intrusion elements of the integrated low-Btu coal gasification system. Cost estimates for the balance-of-plant requirements associated with advanced energy conversion systems utilizing coal or coal-derived fuels are included
- …