Maxillary nerve block: A comparison between the greater palatine canal and high tuberosity approaches.
Aim: Analgesia and anxiolysis during dental procedures are important for dental care and
patient compliance. This study aims to compare two classical maxillary nerve block (MNB)
techniques: the greater palatine canal (GPC) and the high tuberosity (HT) approaches,
seldom used in routine dental practice.
Methods: The study was conducted on 30 patients, scheduled for sinus lift surgery, who
were randomly divided into 2 groups: the GPC approach to the MNB was used in 15 and the
HT one in the other 15 patients. Anxiolysis was also used, depending on the results of the
pre- preoperative assessment. Patients\u2019 sensations/pain during the procedure, details about
anesthesia, and the dentist\u2019s considerations were all recorded. Data are expressed as mean
\ub1SD. Statistical tests including ANOVA, \u3c72 following Yates correction and linear regression
analysis were carried out. A < 0.05 p value was considered significant.
Results: Study results showed that the anesthesia was effective and constant in the molar
and premolar area. Additional infiltrations of local anesthetics were necessary for vestibular
and palatal areas in the anterior oral cavity, respectively, in the GPC and HT groups. The
two techniques were equally difficult to carry out in the dentist\u2019s opinion. There were
no differences in pain or unpleasant sensations between the two groups, nor were any
anesthesia-related complications reported.
Conclusion: The GPC approach ensures effective anesthesia in the posterior maxillary
region as far as both the dental pulp and the palatal/vestibular mucous membranes are
concerned; the HT approach did not guarantee adequate anesthesia of the pterygopalatine
branch of the maxillary nerve. These regional anesthesia techniques were characterized
by a low incidence of intra and postoperative pain, no noteworthy complications, and high
patient satisfaction
Predictors of long-term adverse events after Absorb bioresorbable vascular scaffold implantation: a 1,933-patient pooled analysis from international registries
Aims: The aim of this study was to investigate the predictors of long-term adverse clinical events after implantation of the everolimus-eluting Absorb bioresorbable vascular scaffold (BVS).
Methods and results: We pooled patient-level databases derived from the large-scale ABSORB EXTEND study and five high-volume international centres. Between November 2011 and November 2015, 1,933 patients underwent PCI with a total of 2,372 Absorb BVS implanted. The median age was 61.0 (IQR 53.0 to 68.6) years, 24% had diabetes, and 68.2% presented with stable coronary artery disease. At a median follow-up of 616 days, MACE occurred in 93 (4.9%) patients, all-cause death in 36 (1.9%) patients, myocardial infarction in 47 (2.5%) patients, and target vessel revascularisation in 72 (3.8%) patients. Definite or probable scaffold thrombosis occurred in 26 (1.3%) patients. On multivariable logistic regression analysis, acute coronary syndromes (hazard ratio [HR] 2.79, 95% confidence interval [CI]: 1.47 to 5.29; p=0.002), dyslipidaemia (HR 1.43, 95% CI: 1.23 to 1.79; p=0.007), scaffold/reference diameter ratio >1.25 (HR 1.49, 95% CI: 1.18 to 1.88; p=0.001), and residual stenosis >15% (HR 1.67, 95% CI: 1.34 to 2.07; p<0.001) were independent predictors of MACE, whereas the use of intravascular imaging was independently associated with a reduction in MACE (HR 0.13, 95% CI: 0.06 to 0.28; p<0.001).
Conclusions: Optimal Absorb BVS implantation and the use of intravascular imaging guidance are associated with lower rates of adverse events at long-term follow-up
Angiographic Findings of the Multicenter Randomized Study With the Sirolimus-Eluting Bx Velocity Balloon-Expandable Stent (RAVEL)
BACKGROUND: Restenosis remains the major limitation of coronary catheter-based intervention. In small vessels, the amount of neointimal tissue is disproportionately greater than the vessel caliber, resulting in higher restenosis rates. In the Randomized Study With the Sirolimus-Eluting Bx Velocity Balloon-Expandable Stent (RAVEL) trial, approximately 40% of the vessels were small (<2.5 mm). The present study evaluates the relationship between angiographic outcome and vessel diameter for sirolimus-eluting stents.
METHODS AND RESULTS: Patients were randomized to receive either an 18-mm bare metal Bx VELOCITY (BS group, n=118), or a sirolimus-eluting Bx VELOCITY stent (SES group, n=120). Subgroups were stratified into tertiles according to their reference diameter (RD; stratum I, RD 2.84 mm). At 6-month follow-up, the restenosis rate in the SES group was 0% in all strata (versus 35%, 26%, and 20%, respectively, in the BS group). In-stent late loss was 0.01+/-0.25 versus 0.80+/-0.43 mm in stratum I, 0.01+/-0.38 versus 0.88+/-0.57 mm in stratum II, and -0.06+/-0.35 versus 0.74+/-0.57 mm in stratum III (SES versus BS). In SES, the minimal lumen diameter (MLD) remained unchanged (Delta -0.72 to 0.72 mm) in 97% of the lesions and increased (=late gain, DeltaMLD <-0.72 mm) in 3% of the lesions. Multivariate predictors for late loss were treatment allocation (P<0.001) and postprocedural MLD (P= 0.008).
CONCLUSIONS: Sirolimus-eluting stents prevent neointimal proliferation and late lumen loss irrespective of the vessel diameter. The classic inverse relationship between vessel diameter and restenosis rate was seen in the bare stent group but not in the sirolimus-eluting stent group
High-Sensitivity C-Reactive Protein and Acute Kidney Injury in Patients with Acute Myocardial Infarction: A Prospective Observational Study
Background. Accumulating evidence suggests that inflammation plays a key role in acute kidney injury (AKI) pathogenesis. We explored the relationship between high-sensitivity C-reactive protein (hs-CRP) and AKI in acute myocardial infarction (AMI). Methods. We prospectively included 2,063 AMI patients in whom hs-CRP was measured at admission. AKI incidence and a clinical composite of in-hospital death, cardiogenic shock, and acute pulmonary edema were the study endpoints. Results. Two-hundred-thirty-four (11%) patients developed AKI. hs-CRP levels were higher in AKI patients (45 \ub1 87 vs. 16 \ub1 41 mg/L; p < 0.0001). The incidence and severity of AKI, as well as the rate of the composite endpoint, increased in parallel with hs-CRP quartiles (p for trend <0.0001 for all comparisons). A significant correlation was found between hs-CRP and the maximal increase of serum creatinine (R = 0.23; p < 0.0001). The AUC of hs-CRP for AKI prediction was 0.69 (p < 0.001). At reclassification analysis, addition of hs-CRP allowed to properly reclassify 14% of patients when added to creatinine and 8% of patients when added to a clinical model. Conclusions. In AMI, admission hs-CRP is closely associated with AKI development and severity, and with in-hospital outcomes. Future research should focus on whether prophylactic renal strategies in patients with high hs-CRP might prevent AKI and improve outcome
are drug eluting stents superior to bare metal stents in patients with unprotected non bifurcational left main disease insights from a multicentre registry
Aims To compare long-term clinical outcome following drug-eluting stents (DES) or bare-metal stents (BMS) implantation on lesions located at the ostium or the shaft of the left main in a large real-world population. The advent of DES decreased the risk of unprotected left main coronary artery (ULMCA) restenosis when compared with BMS, but it is unclear if this advantage continues when non-bifurcational lesions are considered. Methods and results The GISE-SICI registry is a retrospective, observational multicentre registry promoted by the Italian Society of Invasive Cardiology in which 19 high-volume participating centres enrolled 1453 consecutive patients who underwent percutaneous coronary intervention on ULMCA between January 2002 and December 2006. From the registry, a total of 479 consecutive patients with ostial and shaft lesions who underwent DES ( n = 334) or BMS ( n = 145) implantation were analysed with extensive multivariable and propensity score adjustments. At 3-year follow-up, risk-adjusted survival rates were higher in patients treated with DES than in those treated with BMS. The adjusted hazard ratio (HR) for the risk of mortality after DES implantation relative to BMS implantation was 0.37 (95% CI: 0.15–0.96, P = 0.04). The adjusted HR for the risk of cardiac mortality was 0.31 (95% CI: 0.09–1.04, P = 0.06). The adjusted 3-year rates of target lesion revascularization (TLR) were not significantly lower in the DES group than in the BMS group ( P = 0.60). Conclusion In a large population of patients with lesions located at the ostium or the shaft of the left main in a real-world setting, DES were associated with favourable clinical outcomes when compared with BMS, although there was no evidence of a significant reduction in TLR with DES vs. BMS
Comparing the safety and effectiveness of five leading new-generation devices for transcatheter aortic valve implantation: Twelve-month results from the RISPEVA study
Objectives. The management of severe aortic stenosis has been revolutionized by the introduction of transcatheter aortic valve implantation (TAVI), especially in patients at intermediate, high, or prohibitive surgical risk. There is uncertainty, however, regarding the comparative effectiveness and safety of contemporary TAVI devices. Methods. We queried detailed data from the ongoing national Italian TAVI registry and compared baseline features, procedural details, and 12-month outcomes of Acurate Neo (Boston Scientific), Evolut Pro/R (Medtronic), Lotus (Boston Scientific), Portico (Abbott Vascular), and Sapien/ Sapien S3 Ultra (Edward Lifesciences) transcatheter aortic valves. Several endpoints were collected and appraised, including the composite of death, stroke, myocardial infarction (MI), major bleeding, major vascular complication, surgical aortic valve replacement and transcatheter aortic valve reimplantation, which were deemed major adverse events (MAEs). Results. A total of 1976 patients were included, with 234 treated with Acurate, 703 with Evolut, 151 with Lotus, 347 with Portico, and 541 with Sapien. Twelve-month events were not significantly different among the 5 devices, including death (P=.29) and MAE (P=.21), with the notable exception of major vascular complications, which were more common with Acurate and Sapien (P<.001) and permanent pacemaker implantation, which was more frequent with Lotus and Evolut (P<.001). Differences in MAE were more pronounced in women and subjects with prior cardiac surgery, with the lowest event rates in the Evolut group. Propensity-score adjusted analysis suggested that Acurate, Evolut, Portico, and Sapien were all associated with similarly favorable results, whereas adverse events were more evident with Lotus (P<.05). Conclusion. Leading current-generation TAVI devices offer similarly favorable results at mid-term follow-up
Impact of Fractional Flow Reserve Derived from Coronary Computed Tomography Angiography on Heart Team Treatment Decision-Making in Patients with Multivessel Coronary Artery Disease: Insights from the SYNTAX III REVOLUTION Trial
Background: Fractional flow reserve (FFR) is a reliable tool for the functional assessment of coronary stenoses. FFR computed tomography (CT) derived (FFRCT) has shown to be accurate, but its clinical usefulness in patients with complex coronary artery disease remains to be investigated. The present study sought to determine the impact of FFRCT on heart team's treatment decision-making and selection of vessels for revascularization in patients with 3-vessel coronary artery disease. Methods: The trial was an international, multicenter study randomizing 2 heart teams to make a treatment decision between percutaneous coronary interventions and coronary artery bypass grafting using either coronary computed tomography angiography or conventional angiography. The heart teams received the FFRCT and had to make a treatment decision and planning integrating the functional component of the stenoses. Each heart team calculated the anatomic SYNTAX score, the noninvasive functional SYNTAX score and subsequently integrated the clinical information to compute the SYNTAX score III providing a treatment recommendation, that is, coronary artery bypass grafting, percutaneous coronary intervention, or equipoise coronary artery bypass grafting-percutaneous coronary intervention. The primary objective was to determine the proportion of patients in whom FFRCT changed the treatment decision and planning. Results: Overall, 223 patients were included. Coronary computed tomography angiography assessment was feasible in 99% of the patients and FFRCT analysis in 88%. FFRCT was available for 1030 lesions (mean FFRCT value 0.64\ub113). A treatment recommendation of coronary artery bypass grafting was made in 24% of the patients with coronary computed tomography angiography with FFRCT. The addition of FFRCT changed the treatment decision in 7% of the patients and modified selection of vessels for revascularization in 12%. With conventional angiography as reference, FFRCT assessment resulted in reclassification of 14% of patients from intermediate and high to low SYNTAX score tertile. Conclusions: In patients with 3-vessel coronary artery disease, a noninvasive physiology assessment using FFRCT changed heart team's treatment decision-making and procedural planning in one-fifth of the patients
Randomized evaluation of polytetrafluoroethylene-covered stent in saphenous vein grafts: the Randomized Evaluation of polytetrafluoroethylene COVERed stent in Saphenous vein grafts (RECOVERS) Trial
Treatment of lesions located in saphenous vein grafts (SVGs) is associated with increased procedural risk and a high rate of restenosis
Visual Evoked Potentials Change as Heart Rate and Carotid Pressure Change
The relationship between cardiovascular activity and the brain was explored by recording visual evoked potentials from the occipital regions of the scalp during systolic and diastolic pressure (Experiment I) and during fast and slow heartbeats at systolic and diastolic pressure (Experiment II). Visual evoked potentials changed significantly as heart rate and carotid pressure fluctuated normally, and these changes were markedly different in the right and left cerebral hemispheres. Evoked potentials recorded from the right hemisphere during various cardiac events differed significantly, whereas those recorded from the left did not. In both experiments, differences in the right hemisphere were due primarily to the P1 component, which was larger at diastolic than at systolic pressure. The present findings are consistent with formulations from behavioral studies suggesting that baroreceptor activity can influence sensory intake, and suggest that hemispheric specialization may play an important role in the relationship between cardiac events, the brain and behavior.Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/73146/1/j.1469-8986.1982.tb02579.x.pd
- …