28 research outputs found

    Quantitative Flow Ratio to Predict Nontarget Vessel-Related Events at 5 Years in Patients With ST-Segment-Elevation Myocardial Infarction Undergoing Angiography-Guided Revascularization.

    Get PDF
    Background In ST-segment-elevation myocardial infarction, angiography-based complete revascularization is superior to culprit-lesion-only percutaneous coronary intervention. Quantitative flow ratio (QFR) is a novel, noninvasive, vasodilator-free method used to assess the hemodynamic significance of coronary stenoses. We aimed to investigate the incremental value of QFR over angiography in nonculprit lesions in patients with ST-segment-elevation myocardial infarction undergoing angiography-guided complete revascularization. Methods and Results This was a retrospective post hoc QFR analysis of untreated nontarget vessels (any degree of diameter stenosis [DS]) from the randomized multicenter COMFORTABLE AMI (Comparison of Biolimus Eluted From an Erodible Stent Coating With Bare Metal Stents in Acute ST-Elevation Myocardial Infarction) trial by assessors blinded for clinical outcomes. The primary end point was cardiac death, spontaneous nontarget vessel myocardial infarction, and clinically indicated nontarget vessel revascularization (ie, ≥70% DS by 2-dimensional quantitative coronary angiography or ≥50% DS and ischemia) at 5 years. Of 1161 patients with ST-segment-elevation myocardial infarction, 946 vessels in 617 patients were analyzable by QFR. At 5 years, the rate of the primary end point was significantly higher in patients with QFR ≤0.80 (n=35 patients, n=36 vessels) versus QFR >0.80 (n=582 patients, n=910 vessels) (62.9% versus 12.5%, respectively; hazard ratio [HR], 7.33 [95% CI, 4.54-11.83], P30% DS by 3-dimensional quantitative coronary angiography. Conclusions Our study suggests incremental value of QFR over angiography-guided percutaneous coronary intervention for nonculprit lesions among patients with ST-segment-elevation myocardial infarction undergoing primary percutaneous coronary intervention

    TCT-4 Efficacy and Safety of Concurrent Administration of Clopidogrel-loading (600mg) and Prasugrel-loading (60mg) in Patients with Acute ST-Segment Elevation Myocardial Infarction

    Get PDF
    Background: Current STEMI guideline recommendations limit the use of prasugrel to clopidogrel-naïve patients. However, in daily clinical practice a considerable proportion of STEMI patients undergoing primary PCI are preloaded with clopidogrel. Whether the use of prasugrel in clopidogrel pretreated STEMI patients is safe remains unknown. Similarly, the efficacy of a combined loading dose regimen has not been evaluated. Methods: Between 1 September 2009 and 15 October 2012, a total of 1,157 STEMI patients were included in the randomized COMFORTABLE AMI trial (NCT 00962416) and 891 STEMI patients in the SPUM ACS registry (NCT 01000701) at 12 centers. Patients were divided into three groups according to type of peri-procedural antiplatelet loading: (1) Clopidogrel and subsequent Prasugrel loading dose [CP], (2) Prasugrel loading dose alone [P] (3) Clopidogrel loading dose alone [C]; 23 patients were excluded because they were not exposed to Clopidogrel and Prasugrel. The primary safety endpoint was the rate of BARC type 3, 4 and 5 bleeding at 30 days. The primary efficacy endpoint was the composite of cardiac death, nonfatal MI and nonfatal stroke at 30 days. Outcomes were analyzed using Cox's Regressions (crude) and multinomial ITPW weighted Cox's Regressions. Results: A total of 2,025 patients were analysed of whom 428 (21.1%) had received CP, 447 (22.1%) patients P alone, and 1,150 (56.8%) patients C alone. The primary safety endpoint was observed among 1.2% of CP, 1.6% of P, and 1.5% of C patients (CP vs C ad. HR 0.99 (0.36-2.72), PC vs P ad. HR 0.73 (0.22-2.41). The primary safety endpoint occurred less frequently among CP (1.9%) compared with C patients (5.0%, adjusted HR 0.47 (0.22-1.00), but with similar frequency among P and C patients (2.9% vs 5.0%, ad. HR 0.68 (0.27-1.73). The net clinical benefit outcome parameter tended to be lower among CP (2.8%) compared with C patients (6.3%, ad. HR 0.56 (0.30-1.05), whereas no significant difference was observed between P and C patients (3.8% vs 6.3%, ad. HR 0.85 (0.39-1.86). Conclusions: Among STEMI patients preloaded with Clopidogrel, the concurrent administration of a Prasugrel loading dose appears safe and potentially more effective than Clopiogrel alone

    Gljivice kao sastavni dio bioaerosola u nastambama za muzne krave i nesilice konzumnih jaja

    Get PDF
    The air of animal dwellings can contain great amounts of bioaerosol composed of dust, bacteria, fungi, and endotoxins. The composition may depend on animal species, building construction, animal accommodation, and microclimate parameters, to name just a few factors. Pathogens contained may be a serious threat to animal and human health. The aim of our study was to analyse the fungi aerosol content in a stable housing dairy cows and in a coop for laying hens over the three autumn months of 2007. The air was sampled on Petri dishes with Sabouraud glucose agar. After laboratory treatment, we identifi ed the most common fungi. Their count in the stable ranged from 3.98x103 CFU m-3 to 5.11x104 CFU m-3 and in the coop from 6.89 x104 CFU m-3 to 1.13x105 CFU m-3. The difference between the two animal dwellings was statistically different at the level of p<0.05. In both dwellings, the most common were the fungi Aspergillus sp., Penicillium sp., and yeasts, followed by Cladosporium sp., Fusarium sp., Mucor sp., Scopulariopsis sp., Alternaria sp., and Rhizopus sp. Our results are entirely in line with values reported in literature and are at the lower end of the range. They call for further investigation that would eventually lead to setting air quality standards for animal dwellings and to developing reliable monitoring systems in order to ensure safe food and safe environment.U zraku nastambi za držanje životinja stvaraju se znatne količine bioaerosola. Njega čine prašina, bakterije, gljivice, endotoksini i plinovi. Brojnost im ovisi o građevinsko-tehničkim značajkama nastambi, naseljenosti životinjama, načinu držanja, temperaturno-vlažnim odnosima u staji i aktivnostima oko hranjenja, mužnje, skupljanja jaja i drugih poslova. Ove čestice, ako su patogene, mogu biti ozbiljna prijetnja za zdravlje ljudi. Mjerenja su obavljana u staji muznih krava te u objektu za nesilice, 2007. godine, tijekom tri jesenja mjeseca. Zrak je uzorkovan na Petrijeve zdjelice sa Sabouraudovim glukoznim agarom, uređajem MAS 100. Nakon obrade u laboratoriju, prema osnovnim i mikromorfološkim osobinama poraslih kolonija identifi cirani su najčešće zastupljeni rodovi gljivica. Srednja vrijednost broja gljivica u zraku staje za muzne krave kretala se od 3,98x103 CFU m-3 do 5,11x104 CFU m-3. Broj gljivica u zraku objekta za nesilice kretao se od 6,89x104 CFU m-3 do 1,13x105 CFU m-3. Ove vrijednosti statistički su se značajno razlikovale na razini p<0,05. U obje pretraživane nastambe najčešće su bili zastupljeni rodovi Aspergillus, Penicillium i kvasnice. U manjem postotku utvrđene su gljivice iz rodova Cladosporium sp., Fusarium sp., Mucor sp., Scopulariopsis sp., Alternaria sp. i Rhizopus sp. Rezultati ovih istraživanja o kvantitativnom i kvalitativnom sastavu gljivica u zraku pretraženih nastambi potpuno su u skladu s vrijednostima zabilježenim u literaturi te se nalaze na donjim granicama opisanih raspona. Utvrđeni broj i rodovi gljivica ukazuju na nužnost daljnjih istraživanja te potrebu postavljanja standardnih vrijednosti glede kvalitete zraka u nastambama za životinje, kao i razvoj vjerodostojnog sustava praćenja navedenih čimbenika, s ciljem stvaranja sigurne hrane i sigurnog okoliša

    Pulmonary artery pressure and cardiac function in children and adolescents after rapid ascent to 3,450 m.

    No full text
    High-altitude destinations are visited by increasing numbers of children and adolescents. High-altitude hypoxia triggers pulmonary hypertension that in turn may have adverse effects on cardiac function and may induce life-threatening high-altitude pulmonary edema (HAPE), but there are limited data in this young population. We, therefore, assessed in 118 nonacclimatized healthy children and adolescents (mean ± SD; age: 11 ± 2 yr) the effects of rapid ascent to high altitude on pulmonary artery pressure and right and left ventricular function by echocardiography. Pulmonary artery pressure was estimated by measuring the systolic right ventricular to right atrial pressure gradient. The echocardiography was performed at low altitude and 40 h after rapid ascent to 3,450 m. Pulmonary artery pressure was more than twofold higher at high than at low altitude (35 ± 11 vs. 16 ± 3 mmHg; P &lt; 0.0001), and there existed a wide variability of pulmonary artery pressure at high altitude with an estimated upper 95% limit of 52 mmHg. Moreover, pulmonary artery pressure and its altitude-induced increase were inversely related to age, resulting in an almost twofold larger increase in the 6- to 9- than in the 14- to 16-yr-old participants (24 ± 12 vs. 13 ± 8 mmHg; P = 0.004). Even in children with the most severe altitude-induced pulmonary hypertension, right ventricular systolic function did not decrease, but increased, and none of the children developed HAPE. HAPE appears to be a rare event in this young population after rapid ascent to this altitude at which major tourist destinations are located

    Randomized comparison of biodegradable polymer sirolimus-eluting stents versus durable polymer everolimus-eluting stents for percutaneous coronary revascularization: Rationale and design of the BIOSCIENCE trial.

    Get PDF
    BACKGROUND: Biodegradable polymers for release of antiproliferative drugs from metallic drug-eluting stents aim to improve long-term vascular healing and efficacy. We designed a large scale clinical trial to compare a novel thin strut, cobalt-chromium drug-eluting stent with silicon carbide-coating releasing sirolimus from a biodegradable polymer (O-SES, Orsiro; Biotronik, Bülach, Switzerland) with the durable polymer-based Xience Prime/Xpedition everolimus-eluting stent (EES) (Xience Prime/Xpedition stent, Abbott Vascular, IL) in an all-comers patient population. DESIGN: The multicenter BIOSCIENCE trial (NCT01443104) randomly assigned 2,119 patients to treatment with biodegradable polymer sirolimus-eluting stents (SES) or durable polymer EES at 9 sites in Switzerland. Patients with chronic stable coronary artery disease or acute coronary syndromes, including non-ST-elevation and ST-elevation myocardial infarction, were eligible for the trial if they had at least 1 lesion with a diameter stenosis &gt;50% appropriate for coronary stent implantation. The primary end point target lesion failure (TLF) is a composite of cardiac death, target vessel myocardial infarction, and clinically driven target lesion revascularization within 12 months. Assuming a TLF rate of 8% at 12 months in both treatment arms and accepting 3.5% as a margin for noninferiority, inclusion of 2,060 patients would provide more than 80% power to detect noninferiority of the biodegradable polymer SES compared with the durable polymer EES at a 1-sided type I error of 0.05. Clinical follow-up will be continued through 5 years. CONCLUSION: The BIOSCIENCE trial will determine whether the biodegradable polymer SES is noninferior to the durable polymer EES with respect to TLF

    Impact of Patient and Lesion Complexity on Long-Term Outcomes Following Coronary Revascularization With New-Generation Drug-Eluting Stents.

    Get PDF
    Long-term clinical outcomes of new-generation drug-eluting stents in complex anatomic and clinical settings are not well defined. This study assessed the impact of patient and lesion complexity on 2-year outcomes after coronary revascularization with ultrathin strut biodegradable-polymer (BP) sirolimus-eluting stents (SES) versus durable-polymer (DP) everolimus-eluting stents (EES). In a prespecified analysis of the BIOSCIENCE randomized trial (NCT01443104), complex patients (911 of 2,119; 43%) were defined by the presence of acute ST-elevation myocardial infarction (MI); left ventricular ejection fraction ≤30%; renal dysfunction; insulin-treated diabetes; treatment of ostial lesion, bypass graft, unprotected left main lesion; or 3-vessel intervention. The primary end point was target lesion failure (TLF), a composite of cardiac death, target vessel MI, and clinically indicated target lesion revascularization. At 2 years, complex compared with simple patients had a greater risk of TLF (14.5% vs 7.4%, risk ratio 2.05, 95% confidence interval 1.56 to 2.69; p &lt;0.001). The difference was sustained beyond 1 year on landmark analysis. Complex patients had higher rates of the patient-oriented composite end point of death, any MI, or any revascularization (23% vs 14.4%; p &lt;0.001) as well as definite stent thrombosis (1.6% vs 0.4%, p = 0.006). There were no differences in TLF and patient-oriented composite end point between the BP-SES versus DP-EES, consistently among simple and complex patients. In conclusion, patient and lesion complexity had a durable adverse impact on clinical outcomes throughout 2 years of follow-up in this all-comers randomized trial. Safety and efficacy of new-generation BP-SES and DP-EES were comparable, irrespective of complexity status

    Ultrathin-strut, biodegradable-polymer, sirolimus-eluting stents versus thin-strut, durable-polymer, everolimus-eluting stents for percutaneous coronary revascularisation: 5-year outcomes of the BIOSCIENCE randomised trial.

    Get PDF
    Drug-eluting stents combining an ultrathin cobalt-chromium stent platform with a biodegradable polymer eluting sirolimus have been shown to be non-inferior or superior to thin-strut, durable-polymer, everolimus-eluting stents in terms of 1 year safety and efficacy outcomes. In the randomised, single-blind, multicentre, non-inferiority BIOSCIENCE trial, we compared biodegradable-polymer sirolimus-eluting stents with durable-polymer everolimus-eluting stents in patients with chronic stable coronary artery disease or acute coronary syndromes. Here, we assess the final 5-year clinical outcomes of BIOSCIENCE with regards to the primary clinical outcome of target lesion failure, which was a composite of cardiac death, target vessel myocardial infarction, and clinically indicated target lesion revascularisation. The primary analysis was done by intention to treat. The BIOSCIENCE trial is registered with ClinicalTrials.gov, number NCT01443104. 2008 (95%) of 2119 patients recruited between March 1, 2012, and May 31, 2013, completed 5 years of follow-up. Target lesion failure occurred in 198 patients (cumulative incidence 20·2%) treated with biodegradable-polymer sirolimus-eluting stents and in 189 patients (18·8%) treated with durable-polymer everolimus-eluting stents (rate ratio [RR] 1·07, 95% CI 0·88-1·31; p=0·487). All-cause mortality was significantly higher in patients treated with biodegradable-polymer sirolimus-eluting stents than in those treated with durable-polymer everolimus-eluting stents (14·1% vs 10·3%; RR 1·36, 95% CI 1·06-1·75; p=0·017), driven by a difference in non-cardiovascular deaths. We observed no difference between groups in cumulative incidence of definite stent thrombosis at 5 years (1·6% in both groups; 1·02, 0·51-2·05; p=0·950). 5-year risk of target lesion failure among all-comer patients undergoing percutaneous coronary intervention is similar after implantation of ultrathin-strut, biodegradable-polymer, sirolimus-eluting stents or thin-strut, durable-polymer, everolimus-eluting stents. Higher incidences of all-cause and non-cardiovascular mortality in patients treated with biodegradable-polymer stents eluting sirolimus than in those treated with durable-polymer stents eluting everolimus warrant careful observation in ongoing clinical trials. Clinical Trials Unit of the University of Bern and Biotronik
    corecore