23 research outputs found

    Quality assessment of an interferon-gamma release assay for tuberculosis infection in a resource-limited setting

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>When a test for diagnosis of infectious diseases is introduced in a resource-limited setting, monitoring quality is a major concern. An optimized design of experiment and statistical models are required for this assessment.</p> <p>Methods</p> <p>Interferon-gamma release assay to detect tuberculosis (TB) infection from whole blood was tested in Hanoi, Viet Nam. Balanced incomplete block design (BIBD) was planned and fixed-effect models with heterogeneous error variance were used for analysis. In the first trial, the whole blood from 12 donors was incubated with nil, TB-specific antigens or mitogen. In 72 measurements, two laboratory members exchanged their roles in harvesting plasma and testing for interferon-gamma release using enzyme linked immunosorbent assay (ELISA) technique. After intervention including checkup of all steps and standard operation procedures, the second trial was implemented in a similar manner.</p> <p>Results</p> <p>The lack of precision in the first trial was clearly demonstrated. Large within-individual error was significantly affected by both harvester and ELISA operator, indicating that both of the steps had problems. After the intervention, overall within-individual error was significantly reduced (<it>P </it>< 0.0001) and error variance was no longer affected by laboratory personnel in charge, indicating that a marked improvement could be objectively observed.</p> <p>Conclusion</p> <p>BIBD and analysis of fixed-effect models with heterogeneous variance are suitable and useful for objective and individualized assessment of proficiency in a multistep diagnostic test for infectious diseases in a resource-constrained laboratory. The action plan based on our findings would be worth considering when monitoring for internal quality control is difficult on site.</p

    Diabetes Is the Main Factor Accounting for Hypomagnesemia in Obese Subjects

    Get PDF
    OBJECTIVE: Type 2 diabetes (T2DM) and obesity are associated with magnesium deficiency. We aimed to determine whether the presence of type 2 diabetes and the degree of metabolic control are related to low serum magnesium levels in obese individuals. METHODS: A) Case-control study: 200 obese subjects [50 with T2DM (cases) and 150 without diabetes (controls)] prospectively recruited. B) Interventional study: the effect of bariatric surgery on serum magnesium levels was examined in a subset of 120 obese subjects (40 with type 2 diabetes and 80 without diabetes). RESULTS: Type 2 diabetic patients showed lower serum magnesium levels [0.75±0.07 vs. 0.81±0.06 mmol/L; mean difference -0.06 (95% CI -0.09 to -0.04); p<0.001] than non-diabetic patients. Forty-eight percent of diabetic subjects, but only 15% of non-diabetic subjects showed a serum magnesium concentration lower than 0.75 mmol/L. Significant negative correlations between magnesium and fasting plasma glucose, HbA1c, HOMA-IR, and BMI were detected. Multiple linear regression analysis showed that fasting plasma glucose and HbA1c independently predicted serum magnesium. After bariatric surgery serum magnesium increased only in those patients in whom diabetes was resolved, but remain unchanged in those who not, without difference in loss weight between groups. Changes in serum magnesium negatively correlated with changes in fasting plasma glucose and HbA1c. Absolute changes in HbA1c independently predicted magnesium changes in the multiple linear regression analysis. CONCLUSIONS: Our results provide evidence that the presence of diabetes and the degree of metabolic control are essential in accounting for the lower levels of magnesium that exist in obese subjects
    corecore