372 research outputs found

    Spontaneous bilateral subdural haematomas in the posterior cranial fossa revealed by MRI

    Get PDF
    A 52-year-old woman treated for acute myeloproliferative disease developed progressive stupor. CT showed obstructive hydrocephalus resulting from unexplained mass effect on the fourth ventricle. MRI revealed bilateral extra-axial collections in the posterior cranial fossa, giving high signal on T1- and T2-weighted images, suggesting subacute subdural haematomas. Subdural haematomas can be suspected on CT when there is unexplained mass effect. MRI may be essential to confirm the diagnosis and plan appropriate treatmen

    Peritoneal Carcinomatosis in Primary Ovarian Cancer Staging: Comparison Between MDCT, MRI, and 18F-FDG PET/CT.

    Get PDF
    PURPOSE: The aim of this study was to compare multidetector CT (MDCT), MRI, and FDG PET/CT imaging for the detection of peritoneal carcinomatosis (PC) in ovarian cancer. PATIENTS AND METHODS: Fifteen women with ovarian cancer and suspected PC underwent MDCT, MRI, and FDG PET/CT, shortly before surgery. Nine abdominopelvic regions were defined according to the peritoneal cancer index. We applied lesion size scores on MDCT and MR and measured FDG PET/CT standard uptake. We blindly read MDCT, MR, and PET/CT before joint review and comparison with histopathology. Receiver operating characteristics analysis was performed. RESULTS: Ten women had PC (67%). Altogether, 135 abdominopelvic sites were compared. Multidetector CT, MRI, and FDG PET/CT had a sensitivity of 96%, 98%, and 95%, and specificity was 92%, 84%, and 96%, respectively. Corresponding receiver operating characteristics area was 0.94, 0.90, and 0.96, respectively, without any significant differences between them (P = 0.12). FDG PET/CT detected supradiaphragmatic disease in 3 women (20%) not seen by MDCT or MRI. CONCLUSIONS: Although MRI had the highest sensitivity and FDG PET/CT had the highest specificity, no significant differences were found between the 3 techniques. Thus, MDCT, as the fastest, most economical, and most widely available modality, is the examination of choice, if a stand-alone technique is required. If inconclusive, PET/CT or MRI may offer additional insights. Whole-body FDG PET/CT may be more accurate for supradiaphragmatic metastatic extension

    Focal neuromyotonia: do I love you?

    Get PDF
    We present a rare case of focal neuromyotonia in a 73-year-old woman with a follow up of 5years. The clinical picture showed a fixed contraction of the 3rd and 4th finger of the left hand. Similar to other published cases, our patient suffered from COPD and was treated with beta-2-sympathomimetics. This clinical picture shows a rare but rather salient differential diagnosis of Dupuytren's contracture. EMG of the affected muscles may yield a diagnosis and prevent the patient from a long and ineffective treatment "odyssey

    Medical physicists' implication in radiological diagnostic procedures: results after 1 y of experience.

    Get PDF
    Since January 2008-de facto 2012-medical physics experts (MPEs) are, by law, to be involved in the optimisation process of radiological diagnostic procedures in Switzerland. Computed tomography, fluoroscopy and nuclear medicine imaging units have been assessed for patient exposure and image quality. Large spreads in clinical practice have been observed. For example, the number of scans per abdominal CT examination went from 1 to 9. Fluoroscopy units showed, for the same device settings, dose rate variations up to a factor of 3 to 7. Quantitative image quality for positron emission tomography (PET)/CT examinations varied significantly depending on the local image reconstruction algorithms. Future work will be focused on promoting team cooperation between MPEs, radiologists and radiographers and on implementing task-oriented objective image quality indicators

    Thalamic Nuclei Clustering on High Angular Resolution Diffusion Images.

    Get PDF
    Thalamic nuclei can be distinguished by their characteristic fiber orientations, which influence the diffusion. Fiber orientations are relatively aligned within a nucleus due to the fact that the cerebrocortical striations within a nucleus all target the same region of cortex. The number of thalamic nuclei reported with histological methods varies with the method employed, although most cyto/myeloarchitec stains identify 14 major nuclei. We present a new approach for thalamic nuclei segmentation on High Angular Diffusion Resolution Images (HARDI), performed with a constrained k-means clustering. As described by John D.Carew[1], it is possible to classify HARDI data based on the shape of the diffusion, thanks to the complex information coming from them. Mette R. Wiegell [2] proposed a thalamic nuclei clustering with k- means on diffusion tensor images, using a combination of a voxel distance and a diffusion tensor distance. In the same way, we use the k-mean algorithm with a weighted sum of two distances to cluster the thalamic nuclei on HARDI data

    Functional mapping of the human visual cortex with intravoxel incoherent motion MRI.

    Get PDF
    Functional imaging with intravoxel incoherent motion (IVIM) magnetic resonance imaging (MRI) is demonstrated. Images were acquired at 3 Tesla using a standard Stejskal-Tanner diffusion-weighted echo-planar imaging sequence with multiple b-values. Cerebro-spinal fluid signal, which is highly incoherent, was suppressed with an inversion recovery preparation pulse. IVIM microvascular perfusion parameters were calculated according to a two-compartment (vascular and non-vascular) diffusion model. The results obtained in 8 healthy human volunteers during visual stimulation are presented. The IVIM blood flow related parameter fD* increased 170% during stimulation in the visual cortex, and 70% in the underlying white matter

    Enamel interproximal reduction during treatment with clear aligners: digital planning versus OrthoCAD analysis

    Get PDF
    Background The aim of the study was to compare the amount of interproximal enamel reduction (IPR) provided on ClinCheck software with the amount of IPR carried out by the orthodontist during treatment with clear aligners. Methods 30 subjects (14 males, 16 females; mean age of 24.53 +/- 13.41 years) randomly recruited from the Invisalign account of the Department of Orthodontics at the University of Rome "Tor Vergata" from November 2018 to October 2019, were collected according to the following inclusion criteria: mild to moderate dento-alveolar discrepancy (1.5-6.5 mm); Class I canine and molar relationship; full permanent dentition (excluding third molars); both arches treated only using Comprehensive Package by Invisalign system; treatment plan including IPR. Pre- (T0) and post-treatment (T1) digital models (.stl files), created from an iTero scan, were collected from all selected patients. The OrthoCAD digital software was used to measure tooth mesiodistal width in upper and lower arches before (T0) and at the end of treatment (T1) before any refinement. The widest mesio-distal diameter was measured for each tooth excluding molars by "Diagnostic" OrthoCAD tool. The total amount of IPR performed during treatment was obtained comparing the sum of mesio-distal widths of all measured teeth at T0 and T1. Significant T1-T0 differences were tested with dependent sample t-test (P < 0.05). Results In the upper arch, IPR was digitally planned on average for 0.62 mm while in the lower arch was on average for 1.92 mm. As for the amount of enamel actually removed after IPR performing, it was on average 0.62 mm in the maxillary arch. In the mandibular arch, the mean of IPR carried out was 1.93 mm. The difference between planned IPR and performed IPR is described: this difference was on average 0.00 mm in the upper arch and 0.01 in the lower arch. Conclusions The amount of enamel removed in vivo corresponded with the amount of IPR planned by the Orthodontist using ClinCheck software

    Impact of carbon dioxide versus air pneumoperitoneum on peritoneal cell migration and cell fate

    Get PDF
    Background: Postoperative systemic immune function is suppressed after open abdominal surgery, as compared with that after minimally invasive abdominal surgery. As a first line of defense, peritoneal macrophages (PMo) and polymorphonuclear neutrophil granulocytes (PMNs) are of primary importance in protecting the body from microorganisms. Previous studies have shown changes in these cell populations over time after open versus laparoscopic surgery. This study aimed to investigate the dynamics of cell recruitment and clearance of peritoneal cells. Methods: Female NMRI mice (33 ± 2 g) were randomly assigned to carbon dioxide (CO2) or air insufflation. Intravasal cells with phagocytic capabilities were selectively stained by intravenous injection of the fluorescent dye PKH26 24 h before surgery. Gas was insufflated into the peritoneal cavity through a catheter, and the pneumoperitoneum was maintained for 30 min. Peritoneal lavage was performed 1, 3, 8, or 24 h after surgery. Apoptotic cells were assessed by flow cytometry using a general caspase substrate. Results: The total peritoneal cell count did not differ between groups. The PKH26-positive PMo level was significantly increased after CO2, as compared with air, at 1 h and 24 h. The ratio of apoptotic PMo did not differ between the groups. In the peritoneal lavage, polymorphonuclear leukocytes (PMNs) were tripled in the air group, as compared with the CO2 group, whereas the ratio of apoptotic PMNs was significantly decreased. There was a higher fraction of PKH26-positive PMNs after air exposure, as compared with that after CO2. Conclusions: Air exposure triggered a higher transmigration rate of PMNs from the blood compartment into the peritoneal cavity and decreased PMN apoptosis, as compared with CO2. The lower proportion of PKH26-positive peritoneal macrophages in the air group might have been attributable to a higher inflammatory stimulation than in the CO2 group, leading to increased emigration of PMo to draining lymph nodes. All the findings underscore a complex cell-specific regulation of cell recruitment and clearance in the peritoneal compartmen
    corecore