602 research outputs found

    Using the Fermilab Proton Source for a Muon to Electron Conversion Experiment

    Get PDF
    The Fermilab proton source is capable of providing 8 GeV protons for both the future long-baseline neutrino program (NuMI), and for a new program of low energy muon experiments. In particular, if the 8 GeV protons are rebunched and then slowly extracted into an external beamline, the resulting proton beam would be suitable for a muon-to-electron conversion experiment designed to improve on the existing sensitivity by three orders of magnitude. We describe a scheme for the required beam manipulations. The scheme uses the Accumulator for momentum stacking, and the Debuncher for bunching and slow extraction. This would permit simultaneous operation of the muon program with the future NuMI program, delivering 10^20 protons per year at 8 GeV for the muon program at the cost of a modest (~10%) reduction in the protons available to the neutrino program.Comment: 18 pages, 7 figure

    The composition of cosmic rays near the Bend (10 to the 15th power eV) from a study of muons in air showers at sea level

    Get PDF
    The distribution of muons near shower cores was studied at sea level at Fermilab using the E594 neutrino detector to sample the muon with E testing 3 GeV. These data are compared with detailed Monte Carlo simulations to derive conclusions about the composition of cosmic rays near the bend in the all particle spectrum. Monte Carlo simulations generating extensive air showers (EAS) with primary energy in excess of 50 TeV are described. Each shower record contains details of the electron lateral distribution and the muon and hadron lateral distributions as a function of energy, at the observation level of 100g/cm. The number of detected electrons and muons in each case was determined by a Poisson fluctuation of the number incident. The resultant predicted distribution of muons, electrons, the rate events are compared to those observed. Preliminary results on the rate favor a heavy primary dominated cosmic ray spectrum in energy range 50 to 1000 TeV

    Study of muons near shower cores at sea level using the E594 neutrino detector

    Get PDF
    The E594 neutrino detector has been used to study the lateral distribution of muons of energy 3 GeV near shower cores. The detector consists of a 340 ton fine grain calorimeter with 400,000 cells of flash chamber and dimensions of 3.7 m x 20 m x 3.7 m (height). The average density in the calorimeter is 1.4 gm/sq cm, and the average Z is 21. The detector was triggered by four 0.6 sq m scintillators placed immediately on the top of the calorimeter. The trigger required at least two of these four counters. The accompanying extensive air showers (EAS) was sampled by 14 scintillation counters located up to 15 m from the calorimeter. Several off line cuts have been applied to the data. Demanding five particles in at least two of the trigger detectors, a total of 20 particles in all of them together, and an arrival angle for the shower 450 deg reduced the data sample to 11053 events. Of these in 4869 cases, a computer algorithm found at least three muons in the calorimeter

    Mechanical Properties of the Tendinous Equine Interosseus Muscle are Affected by in Vivo Transducer Implantation

    Get PDF
    Liquid metal strain gauges (LMSGs) were implanted in the tendinous interosseous muscle, also called suspensory ligament (SL), in the forelimbs of 6 ponies in order to quantify in vivo strains and forces. Kinematics and ground reaction forces were recorded simultaneously with LMSG signals at the walk and the trot prior to implantation, and 3 and 4 days thereafter. The ponies were euthanised and tensile and failure tests were performed on the instrumented tendons and on the tendons of the contra lateral limb, which were instrumented post mortem. The origo–insertional (OI) strain of the SL was computed from pre- and post-operative kinematics, using a 2D geometrical model. The LMSG-recorded peak strain of the SL was 5.4±0.9% at the walk and 9.1±1.3% at the trot. Failure occurred at 15.4±2.1% (mean±S.D.). The LMSG strain was higher than the simultaneously recorded OI strain 0.5±0.7% strain at the walk and 2.2±1.1% strain at the trot. Post-operative OI strains were only slightly higher than pre-operative values. Failure strains of in vivo instrumented SLs were 2.0±1.2% strain higher, and failure forces were slightly lower, than those of the contra lateral SLs that were instrumented post mortem. SL strains appeared to be considerably higher than those found in earlier acute experiments. Differences between in vivo LMSG and OI strains, supported by lower failure strains comparing in vivo and post mortem instrumented SLs, revealed that local changes in tendon mechanical properties occurred within 3 to 4 days after transducer implantation. Therefore, measurements of normal physiological tendon strains should be performed as soon as possible after transducer implantation

    The Influence of Foot Positioning on Ankle Sprains

    Get PDF
    The goal of this study was to examine the influence of changes in foot positioning at touch-down on ankle sprain occurrence. Muscle model driven computer simulations of 10 subjects performing the landing phase of a side-shuffle movement were performed. The relative subtalar joint and talocural joint angles at touchdown were varied, and each subject-specific simulation was exposed to a set of perturbed floor conditions. The touchdown subtalar joint angle was not found to have a considerable influence on sprain occurrence, while increased touchdown plantar flexion caused increased ankle sprain occurrences. Increased touchdown plantar flexion may be the mechanism which causes ankles with a history of ankle sprains to have an increased susceptibility to subsequent sprains. This finding may also reveal a mechanism by which taping of a sprained ankle or the application of an ankle brace leads to decreased ankle sprain susceptibility

    Effects of Foot Orthoses on Skeletal Motion During Running

    Get PDF
    Objective. To quantify the effects of medial foot orthoses on skeletal movements of the calcaneus and tibia during the stance phase in running. Design. Kinematic effects of medial foot orthoses (anterior, posterior, no support) were tested using skeletal (and shoe) markers at the calcaneus and tibia. Background. Previous studies using shoe and skin markers concluded that medially placed orthoses control/reduce foot eversion and tibial rotation. However, it is currently unknown if such orthoses also affect skeletal motion at the lower extremities. Methods. Intracortical Hofman pins with reflective marker triads were inserted under standard local anesthetic into the calcaneus and tibia of five healthy male subjects. The three-dimensional tibiocalcaneal rotations were determined using a joint coordinate system approach. Eversion (skeletal and shoe) and tibial rotation were calculated to study the foot orthoses effects. Results. Orthotic effects on eversion and tibial rotations were found to be small and unsystematic over all subjects. Differences between the subjects were significantly larger (pp\u3c0.05). Conclusions. This in vivo study showed that medially placed foot orthoses did not change tibiocalcaneal movement patterns substantially during the stance phase of running. Relevance Orthoses may have only small kinematic effects on the calcaneus and tibia (measured with bone pins) as well as on the shoes (measured with shoe markers) during running of normal subjects. Present results showed that orthotic effects were subject specific and unsystematic across conditions. It is speculated that orthotic effects during the stance phase of running may be mechanical as well as proprioceptive

    Search for the disappearance of muon antineutrinos in the NuMI neutrino beam

    Get PDF
    We report constraints on muon antineutrino oscillation parameters that were obtained by using the two MINOS detectors to measure the 7% antineutrino component of the NuMI neutrino beam. In the Far Detector, we select 130 events in the charged-current muon antineutrino sample, compared to a prediction of 136.4 +/- 11.7(stat) ^{+10.2}_{-8.9}(syst) events under the assumption |dm2bar|=2.32x10^-3 eV^2, snthetabar=1.0. A fit to the two-flavor oscillation approximation constrains |dm2bar|<3.37x10^-3 eV^2 at the 90% confidence level with snthetabar=1.0

    Recent Advances in Thermoplastic Puncture-Healing Polymers

    Get PDF
    Self-healing materials provide a route for enhanced damage tolerance in materials for aerospace applications. In particular, puncture-healing upon impact has the potential to mitigate significant damage caused by high velocity micrometeoroid impacts. This type of material also has the potential to improve damage tolerance in load bearing structures to enhance vehicle health and aircraft durability. The materials being studied are those capable of instantaneous puncture healing, providing a mechanism for mechanical property retention in lightweight structures. These systems have demonstrated healing capability following penetration of fast moving projectiles -- velocities that range from 9 mm bullets shot from a gun (approx.330 m/sec) to close to micrometeoroid debris velocities of 4800 m/sec. In this presentation, we report on a suite of polymeric materials possessing this characteristic. Figure 1 illustrates the puncture healing concept. Puncture healing in these materials is dependent upon how the combination of a polymer's viscoelastic properties responds to the energy input resulting from the puncture event. Projectile penetration increases the temperature in the vicinity of the impact. Self-healing behavior occurs following puncture, whereby energy must be transferred to the material during impact both elastically and inelastically, thus establishing two requirements for puncture healing to occur: a.) The need for the puncture event to produce a local melt state in the polymer material and b.) The molten material has to have sufficient melt elasticity to snap back and close the hole. 1,2 Previous ballistic testing studies revealed that Surlyn materials warmed up to a temperature approx.98 C during projectile puncture (3 C higher than it s melting temperature). 1,2 The temperature increase produces a localized flow state and the melt elasticity to snap back thus sealing the hole. Table 1 lists the commercially polymers studied here, together with their physical properties. The polymers were selected based on chemical structure, tensile strengths, tensile moduli, glass transition temperature, melting temperatures, and impact strength. The thermal properties of the polymers were characterized by Differential Scanning Calorimetry (DSC) and Dynamic Mechanical Analysis (DMA). Mechanical properties were assessed by a Sintech 2W instron according to ASTM D1708 or D638 at crosshead speeds of 5.08 cm/min. 7.6 cm x 7.6 cm panels of the different materials were prepared and ballistic testing was performed at various temperatures. The panels were shot with a .223 caliber semiautomatic rifle from a distance of 23 meters at various temperatures. Chronographs were used to measure initial and final bullet velocity. Temperatures at the site of impact were measured using a FLIR ThermaCAM S60 thermal camera. A Vision Research model Phantom 9 high speed video camera was used to capture high speed video footage of ballistics testing
    corecore