79 research outputs found

    Improving rigid fiberoptic intubation: a comparison of the Bonfils Intubating Fiberscope™ with a novel modification

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The Bonfils intubating fiberscope has a limited upward tip angle of 40° and requires retromolar entry into the hypopharynx. These factors may make its use less desirable when managing the difficult airway because most anesthesia providers are well versed in midline oral intubation rather than the lateral retromolar approach. The <it>Center for Advanced Technology and Telemedicine </it>at the University of Nebraska Medical Center has developed a novel fiberscope with a more anterior 60° curve to allow for easier midline insertion and intubation. The objective of this work was to evaluate the novel fiberscope, in comparison to the Bonfils intubating fiberscope, in terms of use and function in difficult airway intubation.</p> <p>Methods</p> <p>Twenty-two anesthesia providers participated in simulated intubations of a difficult airway mannequin to compare the Bonfils intubating fiberscope with the novel curved Boedeker intubating fiberscope. The intubations were assessed based upon the following variables: recorded Cormack Lehane airway scores, requests for cricoid pressure, time to intubation, number of intubation attempts and success or failure of the procedure.</p> <p>Results</p> <p>Participants using the Bonfils fiberscope recorded an average Cormack Lehane (CL) airway score of 1.67 ± 1.02 (median = 1); with the novel fiberscope, the recorded average airway grade improved to 1.18 ± 0.50 (median = 1). The difference in airway scores was not statistically significant (p = 0.34; Fishers Exact Test comparing CL grades 1&2 vs. 3&4). There was, however, a statistically significant difference in intubation success rates between the two devices. With the Bonfils fiberscope, 68% (15/22) of participants were successful in intubation compared to a 100% success rate in intubation with the novel fiberscope (22/22) (p = 0.008). After the intubation trial, the majority of participants (95%) indicated a preference for the novel fiberscope (n = 20).</p> <p>Conclusions</p> <p>With this data, we can infer that the novel fiberscope curvature appears to improve or maintain the quality of an intubation attempt (airway score, cricoid pressure requirement, intubation time, number of attempts, placement success). The data indicate that the novel fiberscope offers a superior intubation experience to currently available best practices. The instrument was well received and would be welcomed by most study participants should the device become clinically available in the future.</p

    Intestinal ischemia after cardiac surgery: analysis of a large registry.

    Get PDF
    Intestinal ischemia after cardiac surgery is a rare but severe complication with a high mortality. Early surgery can be lifesaving. The aim was to analyze the incidence, outcome, and risk factors for these patients

    Use of ultrasound by emergency medical services: a review

    Get PDF
    Prehospital ultrasound has been deployed in certain areas of the USA and Europe. Physicians, emergency medical technicians, and flight nurses have utilized a variety of medical and trauma ultrasound assessments to impact patient care in the field. The goal of this review is to summarize the literature on emergency medical services (EMS) use of ultrasound to more clearly define the potential utility of this technology for prehospital providers

    Use of ultrasound by emergency medical services: a review

    Get PDF
    Prehospital ultrasound has been deployed in certain areas of the USA and Europe. Physicians, emergency medical technicians, and flight nurses have utilized a variety of medical and trauma ultrasound assessments to impact patient care in the field. The goal of this review is to summarize the literature on emergency medical services (EMS) use of ultrasound to more clearly define the potential utility of this technology for prehospital providers

    Multi-capillary column-ion mobility spectrometry (MCC-IMS) as a new method for the quantification of occupational exposure to sevoflurane in anaesthesia workplaces: an observational feasibility study

    Get PDF
    BACKGROUND: Occupational exposure to sevoflurane has the potential to cause health damage in hospital personnel. Workplace contamination with the substance mostly is assessed by using photoacoustic infrared spectrometry with detection limits of 10 ppbv. Multi-capillary column-ion mobility spectrometry (MCC-IMS) could be an alternative technology for the quantification of sevoflurane in the room air and could be even more accurate because of potentially lower detection limits. The aim of this study was to test the hypothesis that MCC-IMS is able to detect and monitor very low concentrations of sevoflurane (<10 ppbv) and to evaluate the exposure of hospital personnel to sevoflurane during paediatric anaesthesia and in the post anaesthesia care unit (PACU). METHODS: A MCC-IMS device was calibrated to several concentrations of sevoflurane and limits of detection (LOD) and quantification (LOQ) were calculated. Sevoflurane exposure of hospital personnel was measured at two anaesthesia workplaces and time-weighted average (TWA) values were calculated. RESULTS: The LOD was 0.0068 ppbv and the LOQ was 0.0189 ppbv. During paediatric anaesthesia the mean sevoflurane concentration was 46.9 ppbv (8.0 - 314.7 ppbv) with TWA values between 5.8 and 45.7 ppbv. In the PACU the mean sevoflurane concentration was 27.9 ppbv (8.0 – 170.2 ppbv) and TWA values reached from 8.3 to 45.1 ppbv. CONCLUSIONS: MCC-IMS shows a significantly lower LOD and LOQ than comparable methods. It is a reliable technology for monitoring sevoflurane concentrations at anaesthesia workplaces and has a particular strength in quantifying low-level contaminations of sevoflurane. The exposure of the personnel working in these areas did not exceed recommended limits and therefore adverse health effects are unlikely

    Prise en charge des voies aériennes – 1re partie – Recommandations lorsque des difficultés sont constatées chez le patient inconscient/anesthésié

    Get PDF

    [In Process Citation].

    No full text
    corecore