11 research outputs found

    Lipid profile in olympic athletes. proposal for a "lipid athlete score" as a clinical tool to identify high-risk athletes

    Get PDF
    : Dyslipidemia is a major risk factor for atherosclerosis. Identification of dyslipidemia in athletes has raised interest in establishing preventive strategies and reducing cardiovascular (CV) events. Nowadays, targets or "scores" for athletes are undefined. The aim of our study was to create a "Lipid Athlete Score" based on lipid parameters and derive score indexes to identify high-risk athletes. We retrospectively enrolled 957 Olympic athletes practicing different sporting disciplines (power, skills, endurance, and mixed), analyzing their CV profiles and anthropometrics; 55.4% were male, the mean age was 27.1 ± 5 years, and the mean body mass index (BMI) was 23.1 ± 3.2 kg/m2. Three hundred and forty-three athletes (35.8%) were dyslipidemic (LDL ≥ 115 mg/dL or LDL/HDL ≥ 1.90). Multivariate analysis revealed the following: male p = 0.001, OR 1.88 [0.41-2.51], familiarity for dyslipidemia p = 0.001, OR 2.82 [1.72-4.59], BMI ≥ 30 kg/m2p = 0.001, OR 2.53 [1.46-4.38], and fat mass p = 0.001, OR 2.29 [1.38-3.80] were significant. Endurance athletes presented the lowest CV risk. We proposed a lipid athlete score including major (LDL ≥ 115 mg/dL and LDL/HDL ≥ 1.90) and minor criteria (male, BMI > 30 kg/m2 or fat mass >22% for males and 32% for females, familiarity for dyslipidemia, and conventional CV risk factors). Twelve athletes (1.2%) were at high risk, 150 athletes (15.7%) at medium risk, 171 athletes (17.9%) at low risk, and 624 (65.2%) were at no risk. Dyslipidemia is very common in elite athletes. We have defined a specific lipid athlete score based on lipid parameters and derived score indexes for the stratification of risk. In accordance with this tool, a substantial proportion of athletes (16.9%) were at medium-to-high risk and need early preventive strategies to improve their lipid profiles and reduce the future development of atherosclerotic CV diseases

    Association between FT3 Levels and Exercise-Induced Cardiac Remodeling in Elite Athletes

    No full text
    Background: Previous studies demonstrated that variations of fT3, even within the euthyroid range, can influence cardiac function. Our aim was to investigate whether thyroid hormones, even within the euthyroid range, are associated with the magnitude of exercise-induced cardiac remodeling in Olympic athletes. Methods: We evaluated 1342 Olympic athletes (mean age 25.6 ± 5.1) practicing different sporting disciplines (power, skills, endurance, and mixed). Athletes underwent blood testing (thyroid stimulating hormone, fT3, and fT4), echocardiography, and exercise-stress testing. Athletes taking thyroid hormones, affected by thyroiditis, or presenting TSH out of ranges were excluded. Results: The level of thyroid hormones varied according to the type of sporting discipline practiced: endurance athletes presented the lowest TSH (p p = 0.007), and fT4 (p p = 0.0002, R2 = 0.04; skill: p = 0.0009, R2 = 0.05; endurance: p = 0.007, R2 = 0.03; and mixed: p = 0.04, R2 = 0.01). The same results were seen for peak HR in the exercise-stress test in athletes engaged in power, skill, and endurance (respectively, p p = 0.01, R2 = 0.04; and p = 0.005, R2 = 0.02). Moreover, a positive correlation was observed with cardiac dimensions, i.e., interventricular septum (power: p p = 0.02, R2 = 0.03; endurance: p = 0.002, R2 = 0.03; mixed: p p = 0.04, R2 = 0.03), endurance (p = 0.04, R2 = 0.01), and mixed (p = 0.04, R2 = 0.01). Conclusions: Thyroid hormones, even within the euthyroid range, are associated with cardiac adaptive response to exercise and may contribute to exercise-induced cardiac remodeling

    QUBIC: the Q&U Bolometric Interferometer for Cosmology. A novel way to look at the polarized Cosmic Microwave Background.

    Get PDF
    In this paper we describe QUBIC, an experiment that takes up the challenge posed by the detection of primordial gravitational waves with a novel approach, that combines the sensitivity of state-of-the art bolometric detectors with the systematic effects control typical of interferometers. The so-called 'self-calibration' is a technique deeply rooted in the interferometric nature of the instrument and allows us to clean the measured data from instrumental effects. The first module of QUBIC is a dual band instrument (150 GHz and 220 GHz) that will be deployed in Argentina during Fall 2018

    Thermal architecture for the QUBIC cryogenic receiver

    No full text
    QUBIC, the QU Bolometric Interferometer for Cosmology, is a novel forthcoming instrument to measure the B-mode polarization anisotropy of the Cosmic Microwave Background. The detection of the B-mode signal will be extremely challenging; QUBIC has been designed to address this with a novel approach, namely bolometric interferometry. The receiver cryostat is exceptionally large and cools complex optical and detector stages to 40 K, 4 K, 1 K and 350 mK using two pulse tube coolers, a novel 4He sorption cooler and a double-stage 3He/4He sorption cooler. We discuss the thermal and mechanical design of the cryostat, modelling and thermal analysis, and laboratory cryogenic testing

    Performance of NbSi transition-edge sensors readout with a 128 MUX factor for the QUBIC experiment

    No full text
    QUBIC (the Q and U Bolometric Interferometer for Cosmology) is a ground-based experiment which seeks to improve the current constraints on the amplitude of primordial gravitational waves. It exploits the unique technique, among Cosmic Microwave Background experiments, of bolometric interferometry, combining together the sensitivity of bolometric detectors with the control of systematic effects typical of interferometers. QUBIC will perform sky observations in polarization, in two frequency bands centered at 150 and 220 GHz, with two kilo-pixel focal plane arrays of NbSi Transition-Edge Sensors (TES) cooled down to 350 mK. A subset of the QUBIC instrument, the so called QUBIC Technological Demonstrator (TD), with a reduced number of detectors with respect to the full instrument, will be deployed and commissioned before the end of 2018. The voltage-biased TES are read out with Time Domain Multiplexing and an unprecedented multiplexing (MUX) factor equal to 128. This MUX factor is reached with two-stage multiplexing: a traditional one exploiting Superconducting QUantum Interference Devices (SQUIDs) at 1K and a novel SiGe Application-Specific Integrated Circuit (ASIC) at 60 K. The former provides a MUX factor of 32, while the latter provides a further 4. Each TES array is composed of 256 detectors and read out with four modules of 32 SQUIDs and two ASICs. A custom software synchronizes and manages the readout and detector operation, while the TES are sampled at 780 Hz (100kHz/128 MUX rate). In this work we present the experimental characterization of the QUBIC TES arrays and their multiplexing readout chain, including time constant, critical temperature, and noise properties

    QUBIC:Exploring the primordial universe with the Q&U bolometric interferometer

    Get PDF
    In this paper we describe QUBIC, an experiment that will observe the polarized microwave sky with a novel approach, which combines the sensitivity of state-of-the art bolometric detectors with the systematic effects control typical of interferometers. QUBIC unique features are the so-called "self-calibration", a technique that allows us to clean the measured data from instrumental effects, and its spectral imaging power, i.e. the ability to separate the signal in various sub-bands within each frequency band. QUBIC will observe the sky in two main frequency bands: 150 GHz and 220 GHz. A technological demonstrator is currently under testing and will be deployed in Argentina during 2019, while the final instrument is expected to be installed during 2020.Comment: Proceedings of the 2018 ICNFP conference, Crete. Published by Universe arXiv admin note: text overlap with arXiv:1801.0373

    QUBIC: the Q and U bolometric interferometer for cosmology

    No full text
    QUBIC, the Q & U Bolometric Interferometer for Cosmology, is a novel ground-based instrument that has been designed to measure the extremely faint B-mode polarisation anisotropy of the cosmic microwave background at intermediate angular scales (multipoles o
    corecore