354 research outputs found
Review of mechanical vibration tests conducted on control moment gyros and life test fixtures
Experimental vibration studies performed on a number of flight control moment gyros and bearing life test fixtures are summarized. Tests were performed at MSFC, at Wyle Laboratories, Huntsville, Alabama, and at the Bendix Corporation facilities in Teterboro, New Jersey. A description of test and analysis equipment is included as well as test procedures and overall performance rankings. Advanced ultrasonic rolling element bearing fault detection techniques were applied for bearing analysis along with conventional vibration and sound analysis procedures
New detection method for rolling element and bearing defects
Instrument for detecting defects in rolling elements of bearings is described. Detection depends on rate at which rolling elements impact defect and establishes envelope amplitude of ball resonant frequency. Block diagram of instrument is provided and results obtained in conducting tests are reported
Underground coal mine instrumentation and test
The need to evaluate mechanical performance of mine tools and to obtain test performance data from candidate systems dictate that an engineering data recording system be built. Because of the wide range of test parameters which would be evaluated, a general purpose data gathering system was designed and assembled to permit maximum versatility. A primary objective of this program was to provide a specific operating evaluation of a longwall mining machine vibration response under normal operating conditions. A number of mines were visited and a candidate for test evaluation was selected, based upon management cooperation, machine suitability, and mine conditions. Actual mine testing took place in a West Virginia mine
A system for early warning of bearing failure
System for detecting incipient failure in ball bearings is described. Ultrasonic equipment detects bearing system resonance and provides warning signal through electronic circuitry. Detector can be used to evaluate performance of newly installed bearings. Schematic diagram is provided to show components
Development of sensitized pick coal interface detector system
One approach for detection of the coal interface is measurement of the pick cutting hoads and shock through the use of pick strain gage load cells and accelerometers. The cutting drum of a long wall mining machine contains a number of cutting picks. In order to measure pick loads and shocks, one pick was instrumented and telementry used to transmit the signals from the drum to an instrument-type tape recorder. A data system using FM telemetry was designed to transfer cutting bit load and shock information from the drum of a longwall shearer coal mining machine to a chassis mounted data recorder
Development of sensitized pick coal interface detector system
One approach for detection of the coal interface is measurement of pick cutting loads and shock through the use of pick strain gage load cells and accelerometers. The cutting drum of a long wall mining machine contains a number of cutting picks. In order to measure pick loads and shocks, one pick was instrumented and telemetry used to transmit the signals from the drum to an instrument-type tape recorder. A data system using FM telemetry was designed to transfer cutting bit load and shock information from the drum of a longwall shearer coal mining machine to a chassis mounted data recorder. The design of components in the test data system were finalized, the required instruments were assembled, the instrument system was evaluated in an above-ground simulation test, and an underground test series to obtain tape recorded sensor data was conducted
Design and test of a pump failure anticipator
Tests were conducted on two different types of pumps in order to refine the concept and to finalize design details of a positive displacement internal gear pump and a shroudless centrifugal pump. A concept and a system that could be used with pumps to allow a rapid judgement to be made of the suitability of the pump for futher service is developed. Test results and detailed data analysis are included
Design and fabrication of prototype system for early warning of impending bearing failure
Ball bearing performance tests run on several identical ball bearings under a variety of load, speed, temperature, and lubrication conditions are reported. Bearing temperature, torque, vibration, noise, strain, cage speed, etc., were monitored to establish those measurements most suitable as indicators of ball bearing health. Tape records were made under steady-state conditions of a variety of speeds and loads. Sample sections were selected for narrowband spectral analysis with a real time analyzer. An artificial flow was created across the inner race surface of one bearing using an acid etch technique to produce the scratch. Tape records obtained before and after established a characteristic frequency response that identifies the presence of the flow. The signals found most useful as indicators of performance degradation were ultrasonic outputs
A field-based comparison of ammonia emissions from six Irish soil types following urea fertiliser application
peer-reviewedAmmonia (NH3) emissions from a range of soil types have been found to differ under laboratory conditions. However, there is lack of studies comparing NH3 emissions from different soil types under field conditions. The objective was to compare NH3 emissions from six different soil types under similar environmental conditions in the field following urea fertiliser application. The study was conducted on a lysimeter unit and NH3 emissions were measured, using wind tunnels, from six different soil types with varying soil characteristics following urea fertiliser application (80 kg N/ha). On average, 17.6% (% total N applied) was volatilised, and there was no significant difference in NH3 emissions across all soil types. Soil variables, including pH, cation exchange capacity and volumetric moisture, were not able to account for the variation in emissions. Further field studies are required to improve the urea-NH3 emission factor used for Ireland’s NH3 inventory
Detection of epithelial cancer cells in peripheral blood by reverse transcriptase-polymerase chain reaction.
Circulating cancer cells in the blood play a central role in the metastatic process. Their number can be very small and techniques for their detection need to be both sensitive and specific. Polymerase chain reaction (PCR) has been successfully used to detect small numbers of tumour cells in haematological cancer in which abnormalities in DNA are sufficiently consistent to make this possible. For most solid tumours this not yet feasible. However, we have found that reverse transcriptase (RT)-PRC for tissue-specific gene expression is a useful technique for identifying small numbers of circulating cells in melanoma and neuroblastoma patients. In this report we describe detection of colon carcinoma cells by RT-PCR using CK 20 mRNA as a marker. Unlike other cytokeratin genes examined (CK 8 and CK 19), CK 20 was not transcribed in normal haematopoietic cells. This suggests a role for RT-PCR in the detection of colon carcinoma metastasis in blood and bone marrow, using CK 20 as the target gene. Future analysis of clinical material will determine the clinical significance of this technique
- …