37 research outputs found

    Holmium Microparticles for Intratumoral Radioablation

    Get PDF

    Holmium Microparticles for Intratumoral Radioablation

    Get PDF

    Quantitative assessment of required separator fluid volume in multi-infusion settings

    Get PDF
    Background: Administering a separator fluid between incompatible solutions can optimize the use of intravenous lumens. Factors affecting the required separator fluid volume to safely separate incompatible solutions are unknown. Methods: An intravenous tube (2-m, 2-mL, 6-French) containing methylene blue dye was flushed with separator fluid until a methylene blue concentration ⩽2% from initial was reached. Independent variables were administration rate, dye solvent (glucose 5% and NaCl 0.9%), and separator fluid. In the second part of the study, methylene blue, separator fluid, and eosin yellow were administered in various administration profiles using 2- and 4-mL (2 × 2 m, 4-mL, 6-French) intravenous tubes. Results: Neither administration rate nor solvent affected the separator fluid volume (p = 0.24 and p = 0.12, respectively). Glucose 5% as separator fluid required a marginally smaller mean ± SD separator fluid volume than NaCl 0.9% (3.64 ± 0.13 mL vs 3.82 ± 0.11 mL, p < 0.001). Using 2-mL tubing required less separator fluid volume than 4-mL tubing for methylene blue (3.89 ± 0.57 mL vs 4.91 ± 0.88 mL, p = 0.01) and eosin yellow (4.41 ± 0.56 mL vs 5.63 ± 0.15 mL, p < 0.001). Extended tubing required less separator fluid volume/mL of tubing than smaller tubing for both methylene blue (2 vs 4 mL, 1.54 ± 0.22 vs 1.10 ± 0.19, p < 0.001) and eosin yellow (2 vs 4 mL, 1.75 ± 0.22 vs 1.25 ± 0.03, p < 0.001). Conclusion: The separator fluid volume was neither affected by the administration rate nor by solvent. Glucose 5% required a marginally smaller separator fluid volume than NaCl 0.9%, however its clinical impact is debatable. A larger intravenous tubing volume requires a larger separator fluid volume. However, the ratio of separator fluid volume to the tubing’s volume decreases as the tubing volume increases

    Towards more efficient use of intravenous lumens in multi-infusion settings:development and evaluation of a multiplex infusion scheduling algorithm

    Get PDF
    BACKGROUND: Multi-drug intravenous (IV) therapy is one of the most common medical procedures used in intensive care units (ICUs), operating rooms, oncology wards and many other hospital departments worldwide. As drugs or their solvents are frequently chemically incompatible, many solutions must be administered through separate lumens. When the number of available lumens is too low to facilitate the safe administration of these solutions, additional (peripheral) IV catheters are often required, causing physical discomfort and increasing the risk for catheter related complications. Our objective was to develop and evaluate an algorithm designed to reduce the number of intravenous lumens required in multi-infusion settings by multiplexing the administration of various parenteral drugs and solutions. METHODS: A multiplex algorithm was developed that schedules the alternating IV administration of multiple incompatible IV solutions through a single lumen, taking compatibility-related, pharmacokinetic and pharmacodynamic constraints of the relevant drugs into account. The conventional scheduling procedure executed by ICU nurses was used for comparison. The number of lumens required by the conventional procedure (LCONV) and multiplex algorithm (LMX) were compared. RESULTS: We used data from 175,993 ICU drug combinations, with 2251 unique combinations received by 2715 consecutive ICU patients. The mean ± SD number of simultaneous IV solutions was 2.8 ± 1.6. In 27% of all drug combinations, and 61% of the unique combinations the multiplex algorithm required fewer lumens (p  3 lm, versus 12% using the conventional procedure. CONCLUSION: The multiplex algorithm addresses a major issue that occurs in ICUs, operating rooms, oncology wards, and many other hospital departments where several incompatible drugs are infused through a restricted number of lumens. The multiplex algorithm allows for more efficient use of IV lumens compared to the conventional multi-infusion strategy

    A fast and simple method for the simultaneous analysis of midazolam, 1-hydroxymidazolam, 4-hydroxymidazolam and 1-hydroxymidazolam glucuronide in human serum, plasma and urine

    Get PDF
    For the quantification of the sedative and anesthetic drug midazolam and its main (active) metabolites 1-hydroxymidazolam, 4-hydroxymidazolam and 1-hydroxymidazolam glucuronide in human serum, human EDTA plasma, human heparin plasma and human urine a single accurate method by ultra-high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) has been developed. Protein precipitation as sample preparation, without the need of a time-consuming deglucuronidation step for the quantification of 1-hydroxymidazolam glucuronide, resulted in a simple and rapid assay suitable for clinical practice with a total runtime of only 1.1 min. The four components and the isotope-labeled internal standards were separated on a C18 column and detection was performed with a triple-stage quadrupole mass spectrometer operating in positive ionization mode. The method was validated based on the "Guidance for Industry Bioanalytical Method Validation" (Food and Drug Administration, FDA) and the "Guideline on bioanalytical method validation" of the European Medicines Agency (EMA). Linearity was proven over the ranges of 5-1500 μg/L for midazolam, 1-hydroxymidazolam and 4-hydroxymidazolam and 25-5000 μg/L for 1-hydroxymidazolam glucuronide, using a sample volume of 100 μL. Matrix comparison indicated that the assay is also applicable to other human matrices like EDTA and heparin plasma and urine. Stability experiments showed good results for the stability of midazolam, 1-hydroxymidazolam and 1-hydroxymidazolam glucuronide in serum, EDTA and heparin plasma and urine stored for 7 days under different conditions. At room temperature, 4-hydroxymidazo-lam is stable for 7 days in EDTA plasma, but stable for only 3 days in serum and heparin plasma and less than 24 h in urine. All four compounds were found to be stable in serum, EDTA plasma, heparin plasma and urine for 7 days after sample preparation and for 3 freeze-thaw cycles. The assay has been applied in therapeutic drug monitoring of midazolam for (pediatric) intensive care patients

    Intermediate Dose Low-Molecular-Weight Heparin for Thrombosis Prophylaxis:Systematic Review with Meta-Analysis and Trial Sequential Analysis

    Get PDF
    Different doses of low-molecular-weight heparin (LMWH) are registered and used for thrombosis prophylaxis. We assessed benefits and harms of thrombosis prophylaxis with a predefined intermediate-dose LMWH compared with placebo or no treatment in patients at risk of venous thromboembolism (VTE). We performed a systematic review with meta-analyses and trial sequential analyses (TSA) following The Cochrane Handbook for Systematic Reviews of Interventions . Medline, Cochrane CENTRAL, Web of Science, and Embase were searched up to December 2018. Trials were evaluated for risk of bias and quality of evidence was assessed following the Grading of Recommendations Assessment, Development and Evaluation (GRADE) approach. Seventy randomized trials with 34,046 patients were included. Eighteen (26%) had overall low risk of bias. There was a small statistically significant effect of LMWH on all-cause mortality (risk ratio [RR]: 0.96; TSA-adjusted confidence interval [TSA-adjusted CI]: 0.94-0.98) which disappeared in sensitivity analyses excluding ambulatory cancer patients (RR: 0.99; TSA-adjusted CI: 0.84-1.16). There was moderate-quality evidence for a statistically significant beneficial effect on symptomatic VTE (odds ratio [OR]: 0.59; TSA-adjusted CI: 0.53-0.67; number needed to treat [NNT]: 76; 95% CI: 60-106) and a statistically significant harmful effect on major bleeding (Peto OR: 1.66; TSA-adjusted CI: 1.31-2.10; number needed to harm [NNH]: 212; 95% CI: 142-393). There were no significant intervention effects on serious adverse events. The use of intermediate-dose LMWH for thrombosis prophylaxis compared with placebo or no treatment was associated with a small statistically significant reduction of all-cause mortality that disappeared in sensitivity analyses excluding trials that evaluated LMWH for anticancer treatment. Intermediate-dose LMWH provides benefits in terms of VTE prevention while it increases major bleeding

    Improved usability of a multi-infusion setup using a centralized control interface:A task-based usability test

    Get PDF
    The objective of this study was to assess the usability benefits of adding a bedside central control interface that controls all intravenous (IV) infusion pumps compared to the conventional individual control of multiple infusion pumps. Eighteen dedicated ICU nurses volunteered in a between-subjects task-based usability test. A newly developed central control interface was compared to conventional control of multiple infusion pumps in a simulated ICU setting. Task execution time, clicks, errors and questionnaire responses were evaluated. Overall the central control interface outperformed the conventional control in terms of fewer user actions (40 +/- 3 vs. 73 +/- 20 clicks, p <0.001) and fewer user errors (1 +/- 1 vs. 3 +/- 2 errors, p <0.05), with no difference in task execution times (421 +/- 108 vs. 406 +/- 119 seconds, not significant). Questionnaires indicated a significant preference for the central control interface. Despite being novice users of the central control interface, ICU nurses displayed improved performance with the central control interface compared to the conventional interface they were familiar with. We conclude that the new user interface has an overall better usability than the conventional interface

    A population-based study of transformed marginal zone lymphoma:identifying outcome-related characteristics

    Get PDF
    Histological transformation of marginal zone lymphoma (tMZL) into diffuse large B-cell lymphoma is associated with poor outcomes. Clinical characteristics associated with transformation risk and outcome after transformation are largely unknown due to scarcity of data. In this population-based study, competing risk analyses were performed to elucidate clinical characteristics associated with developing transformation among 1793 MZL patients using the Netherlands Cancer Registry. Cox regression analyses were performed to elucidate clinical characteristics associated with risk of relapse and mortality after transformation. Transformation occurred in 75 (4%) out of 1793 MZL patients. Elevated LDH and nodal MZL subtype at MZL diagnosis were associated with an increased risk, and radiotherapy with a reduced risk of developing tMZL. Most tMZL patients received R-(mini)CHOP (n = 53, 71%). Age &gt;60 years and (immuno)chemotherapy before transformation were associated with an increased risk of relapse and mortality after transformation. Two-year progression-free survival (PFS) and overall survival (OS) were 66% (95% CI 52-77%) and 75% (95% CI 62-85%) for R-(mini)CHOP-treated tMZL patients, as compared to a PFS and OS both of 41% (95% CI 19-63%) for patients treated otherwise. Our study offers comprehensive insights into characteristics associated with transformation and survival after transformation, thereby optimizing guidelines and patient counseling.</p

    Holmium-166 radioembolization for the treatment of patients with liver metastases: design of the phase I HEPAR trial

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Intra-arterial radioembolization with yttrium-90 microspheres ( <sup>90</sup>Y-RE) is an increasingly used therapy for patients with unresectable liver malignancies. Over the last decade, radioactive holmium-166 poly(L-lactic acid) microspheres ( <sup>166</sup>Ho-PLLA-MS) have been developed as a possible alternative to <sup>90</sup>Y-RE. Next to high-energy beta-radiation, <sup>166</sup>Ho also emits gamma-radiation, which allows for imaging by gamma scintigraphy. In addition, Ho is a highly paramagnetic element and can therefore be visualized by MRI. These imaging modalities are useful for assessment of the biodistribution, and allow dosimetry through quantitative analysis of the scintigraphic and MR images. Previous studies have demonstrated the safety of <sup>166</sup>Ho-PLLA-MS radioembolization ( <sup>166</sup>Ho-RE) in animals. The aim of this phase I trial is to assess the safety and toxicity profile of <sup>166</sup>Ho-RE in patients with liver metastases.</p> <p>Methods</p> <p>The HEPAR study (Holmium Embolization Particles for Arterial Radiotherapy) is a non-randomized, open label, safety study. We aim to include 15 to 24 patients with liver metastases of any origin, who have chemotherapy-refractory disease and who are not amenable to surgical resection. Prior to treatment, in addition to the standard technetium-99m labelled macroaggregated albumin ( <sup>99m</sup>Tc-MAA) dose, a low radioactive safety dose of 60-mg <sup>166</sup>Ho-PLLA-MS will be administered. Patients are treated in 4 cohorts of 3-6 patients, according to a standard dose escalation protocol (20 Gy, 40 Gy, 60 Gy, and 80 Gy, respectively). The primary objective will be to establish the maximum tolerated radiation dose of <sup>166</sup>Ho-PLLA-MS. Secondary objectives are to assess tumour response, biodistribution, performance status, quality of life, and to compare the <sup>166</sup>Ho-PLLA-MS safety dose and the <sup>99m</sup>Tc-MAA dose distributions with respect to the ability to accurately predict microsphere distribution.</p> <p>Discussion</p> <p>This will be the first clinical study on <sup>166</sup>Ho-RE. Based on preclinical studies, it is expected that <sup>166</sup>Ho-RE has a safety and toxicity profile comparable to that of <sup>90</sup>Y-RE. The biochemical and radionuclide characteristics of <sup>166</sup>Ho-PLLA-MS that enable accurate dosimetry calculations and biodistribution assessment may however improve the overall safety of the procedure.</p> <p>Trial registration</p> <p>ClinicalTrials.gov NCT01031784</p
    corecore