35 research outputs found

    Optical tweezers escape forces

    Get PDF
    With suitable calibration, optical tweezers can be used to measure forces. If the maximum force that can be exerted is of interest, calibration can be performed using viscous drag to remove a particle from the trap, typically by moving the stage. The stage velocity required to remove the particle then gives the escape force. However, the escape force can vary by up to 30% or more, depending on the particle trajectory. This can have significant quantitative impact on measurements. We describe the variation of escape force and escape trajectory, using both experimental measurements and simulations, and discuss implications for experimental measurement of forces

    Phenotype Enhancement Screen of a Regulatory spx Mutant Unveils a Role for the ytpQ Gene in the Control of Iron Homeostasis

    Get PDF
    Spx is a global regulator of genes that are induced by disulfide stress in Bacillus subtilis. The regulon that it governs is comprised of over 120 genes based on microarray analysis, although it is not known how many of these are under direct Spx control. Most of the Spx-regulated genes (SRGs) are of unknown function, but many encode products that are conserved in low %GC Gram-positive bacteria. Using a gene-disruption library of B. subtilis genomic mutations, the SRGs were screened for phenotypes related to Spx-controlled activities, such as poor growth in minimal medium and sensitivity to methyglyoxal, but nearly all of the SRG mutations showed little if any phenotype. To uncover SRG function, the mutations were rescreened in an spx mutant background to determine which mutant SRG allele would enhance the spx mutant phenotype. One of the SRGs, ytpQ was the site of a mutation that, when combined with an spx null mutation, elevated the severity of the Spx mutant phenotype, as shown by reduced growth in a minimal medium and by hypersensitivity to methyglyoxal. The ytpQ mutant showed elevated oxidative protein damage when exposed to methylglyoxal, and reduced growth rate in liquid culture. Proteomic and transcriptomic data indicated that the ytpQ mutation caused the derepression of the Fur and PerR regulons of B. subtilis. Our study suggests that the ytpQ gene, encoding a conserved DUF1444 protein, functions directly or indirectly in iron homeostasis. The ytpQ mutant phenotype mimics that of a fur mutation, suggesting a condition of low cellular iron. In vitro transcription analysis indicated that Spx stimulates transcription from the ytpPQR operon within which the ytpQ gene resides. The work uncovers a link between Spx and control of iron homeostasis

    Calibration of nonspherical particles in optical tweezers using only position measurement

    No full text
    Nonspherical probe particles are an attractive choice for optically-trapped scanning probe microscopy. We show that it is possible to calibrate a trap with a nonspherical particle using only position measurements, without requiring measurement of orientation, using a pseudopotential based on the position occupation probability. It is not necessary to assume the force is linear with displacement

    Escape forces and trajectories in optical tweezers and their effect on calibration

    No full text
    Whether or not an external force can make a trapped particle escape from optical tweezers can be used to measure optical forces. Combined with the linear dependence of optical forces on trapping power, a quantitative measurement of the force can be obtained. For this measurement, the particle is at the edge of the trap, away from the region near the equilbrium position where the trap can be described as a linear spring. This method provides the ability to measure higher forces for the same beam power, compared with using the linear region of the trap, with lower risk of optical damage to trapped specimens. Calibration is typically performed by using an increasing fluid flow to exert an increasing force on a trapped particle until it escapes. In this calibration technique, the particle is usually assumed to escape along a straight line in the direction of fluid-flow. Here, we show that the particle instead follows a curved trajectory, which depends on the rate of application of the force (i.e., the acceleration of the fluid flow). In the limit of very low acceleration, the particle follows the surface of zero axial optical force during the escape. The force required to produce escape depends on the trajectory, and hence the acceleration. This can result in variations in the escape force of a factor of two. This can have a major impact on calibration to determine the escape force efficiency. Even when calibration measurements are all performed in the low acceleration regime, variations in the escape force efficiency of 20% or more can still occur. We present computational simulations using generalized Lorenz-Mie theory and experimental measurements to show how the escape force efficiency depends on rate of increase of force and trapping power, and discuss the impact on calibration. (C) 2015 Optical Society of Americ

    Assessing Medicare beneficiaries’ willingness-to-pay for medication therapy management services

    No full text
    Objectives: To assess Medicare beneficiaries’ willingnessto-pay (WTP) for medication therapy management (MTM) services and determine sociodemographic and clinical characteristics influencing this payment amount. Design: A cross-sectional, descriptive study design was adopted to elicit Medicare beneficiaries’ WTP for MTM. Setting: Nine outreach events in cities across Central/Northern California during Medicare\u27s 2011 open-enrollment period. Participants: A total of 277 Medicare beneficiaries participated in the study. Interventions: Comprehensive MTM was offered to each beneficiary. Pharmacy students conducted the MTM session under the supervision of licensed pharmacists. At the end of each MTM session, beneficiaries were asked to indicate their WTP for the service. Medication, self-reported chronic conditions, and beneficiary demographic data were collected and recorded via a survey during the session. Results: The mean WTP for MTM was 33.15forthe277beneficiariesreceivingtheserviceandansweringtheWTPquestion.WTPbylowincomesubsidyrecipients(mean±standarddeviation;33.15 for the 277 beneficiaries receiving the service and answering the WTP question. WTP by low-income subsidy recipients (mean ± standard deviation; 12.80 ± 24.10)wassignificantlylowerthanfornonsubsidyrecipients(24.10) was significantly lower than for nonsubsidy recipients (41.13 ± 88.79).WTPwassignificantly(positively)correlatedwithnumberofmedicationsregularlytakenandannualoutofpocketdrugcosts.Conclusion:ThemeanWTPforMTMwas88.79). WTP was significantly (positively) correlated with number of medications regularly taken and annual out-of-pocket drug costs. Conclusion: The mean WTP for MTM was 33.15. WTP for MTM significantly varied by race, subsidy status, and number of prescription medications taken. WTP was significantly higher for nonsubsidy recipients than subsidy recipients, and significantly positively correlated with the number of medications regularly taken and the beneficiary rating of the delivered services

    Calibration of force detection for arbitrarily shaped particles in optical tweezers

    No full text
    Force measurement with an optical trap requires calibration of it. With a suitable detector, such as a position-sensitive detector (PSD), it is possible to calibrate the detector so that the force can be measured for arbitrary particles and arbitrary beams without further calibration; such a calibration can be called an "absolute calibration". Here, we present a simple method for the absolute calibration of a PSD. Very often, paired position and force measurements are required, and even if synchronous measurements are possible with the position and force detectors used, knowledge of the force-position curve for the particle in the trap can be highly beneficial. Therefore, we experimentally demonstrate methods for determining the force-position curve with and without synchronous force and position measurements, beyond the Hookean (linear) region of the trap. Unlike the absolute calibration of the force and position detectors, the force-position curve depends on the particle and the trapping beam, and needs to be determined in each individual case. We demonstrate the robustness of our absolute calibration by measuring optical forces on microspheres as commonly trapped in optical tweezers, and other particles such a birefringent vaterite microspheres, red blood cells, and a deformable "blob"

    Recension. De la pyramide au réseau ?

    No full text
    Après plus de vingt années d’écriture commune, ponctuée notamment par cinq ouvrages (dont Jalons pour une théorie critique du droit, 1987, Le système juridique entre ordre et désordre, 1988 et Le droit ou les paradoxes du jeu, 1992), François Ost et Michel van de Kerchove nous offrent avec De la pyramide au réseau ? une version actualisée de leur théorie dialectique du droit. Il s’agit d’une œuvre à la fois pointue et particulièrement aisée d’accès, qui permettra à toute personne qui s’intére..

    Investigating the Role of Interpretation Bias in Mindfulness-Based Treatment of Adults With Generalized Anxiety Disorder

    No full text
    Although mindfulness-based interventions (MBIs) have garnered empirical support for a wide range of psychological conditions, the psychological processes that mediate the relationship between MBIs and subsequent symptomatic improvement are less well-understood. In the present study we sought to examine, for the first time, the relationship between mindfulness, negative interpretation bias as measured by the homophone task, and anxiety among adults with Generalized Anxiety Disorder (GAD). Forty-two individuals with GAD completed measures of mindfulness, interpretation bias, and anxiety before and after treatment with Mindfulness-based Stress Reduction (MBSR). Contrary to prior research, we did not find evidence of an indirect relationship between baseline levels of mindfulness and anxiety via negative interpretation bias. MBSR did result in significant reductions in negative interpretation bias from baseline to post-treatment; however, we did not find evidence of an indirect relationship between changes in mindfulness and changes in anxiety via changes in interpretation bias. Taken together, these results provide minimal support for the hypothesized relationship between mindfulness, negative interpretation bias, and anxiety among adults with GAD. Limitations and specific suggestions for further inquiry are discussed
    corecore