3 research outputs found

    Identification of earlier predictors of pregnancy complications through wearable technologies in a brazilian multicentre cohort : maternal actigraphy exploratory study I (MAES-I) study protocol

    No full text
    Non-invasive tools capable of identifying predictors of maternal complications would be a step forward for improving maternal and perinatal health. There is an association between modification in physical activity (PA) and sleep-wake patterns and the occurrence of inflammatory, metabolic, pathological conditions related to chronic diseases. The actigraphy device is validated to estimate PA and sleep-wake patterns among pregnant women. In order to extend the window of opportunity to prevent, diagnose and treat specific maternal conditions, would it be possible to use actigraphy data to identify risk factors for the development of adverse maternal outcomes during pregnancy? A cohort will be held in five centres from the Brazilian Network for Studies on Reproductive and Perinatal Health. Maternal Actigraphy Exploratory Study I (MAES-I) will enrol 400 low-risk nulliparous women who will wear the actigraphy device on their wrists day and night (24 hours/ day) uninterruptedly from 19 to 21 weeks until childbirth. Changes in PA and sleep-wake patterns will be analysed throughout pregnancy, considering ranges in gestational age in women with and without maternal complications such as pre-eclampsia, preterm birth (spontaneous or provider-initiated), gestational diabetes, maternal haemorrhage during pregnancy, in addition to perinatal outcomes. The plan is to design a predictive model using actigraphy data for screening pregnant women at risk of developing specific adverse maternal and perinatal outcomes. Ethics and dissemination MAES-I has been reviewed and approved by each institutional review board and also by the National Council for Ethics in Research. Detailed information about the study is provided in the Brazilian Cohort website (www.medscinet.com/samba) and findings will be published in the scientific literature and institutional webpages94This study was funded by The Bill and Melinda Gates Foundation through the Grand Challenge Exploration program, call 19 (research grant OPP1182749

    Proposal of MUAC as a fast tool to monitor pregnancy nutritional status: results from a cohort study in Brazil

    No full text
    Objective In Brazil, although the assessment of maternal nutritional status is recommended using body mass index (BMI), this is only possible in settings adequately prepared. Midupper arm circumference (MUAC) is another biological variable identified as a tool for rapid assessment of nutritional status that is correlated with BMI. Therefore, we aim to surrogate BMI by MUAC cut-offs for rapid screening of maternal nutritional status starting at midpregnancy.Design Analysis of the multicentre cohort study entitled ‘Preterm SAMBA’ using an approach of validation of diagnostic test.Setting Outpatient prenatal care clinics from five tertiary maternity hospitals from three different Brazilian regions.Participants 1165 pregnant women attending prenatal care services from 2015 to 2018 and with diverse ethnic characteristics who were enrolled at midpregnancy and followed in three visits at different gestational weeks.Primary and secondary outcome measures Sensitivity, specificity, positive and negative predictive values, likelihood ratio and accuracy of MUAC being used instead of BMI for the assessment of nutritional status of women during pregnancy.Results We found a strong correlation between MUAC and BMI, in the three set points analysed (r=0.872, 0.870 and 0.831, respectively). Based on BMI categories of nutritional status, we estimated the best MUAC cut-off points, finding measures according to each category: underweight <25.75 cm (19–39 weeks); overweight 28.11–30.15 cm (19–21 weeks), 28.71–30.60 cm (27–29 weeks) and 29.46–30.25 cm (37–39 weeks); and obese >30.15 cm (19–21 weeks), >30.60 cm (27–29 weeks) and >30.25 cm (37–39 weeks) per gestational week. Therefore, we defined as adequate between 25.75–28.10 cm (19–21 weeks), 25.75–28.70 cm (27–29 weeks) and 25.75–29.45 cm (37–39 weeks) of MUAC.Conclusion We conclude that MUAC can be useful as a surrogate for BMI as a faster screening of nutritional status in pregnant women
    corecore