46 research outputs found

    Matériaux pour la gestion de la lumière fabriqués par voie liquide

    Get PDF
    Light management is a current hot issue for the development of new materials for optics and optoelectronics. In the energy field, more efficient systems at lower costs can be obtained by integrating these structures either to trap the light (photovoltaic) or to extract it (LED technology).Thin film solar cells allow decreasing the amount of photoactive materials but this induces a loss in the absorption due to a shortened path of light. A approach consists in the integration of new structures like photonic crystals to extend the path of light at specific wavelengths in the absorbing medium and thus lead to more coupled guided modes. Researchers focus on methods to elaborate such systems while reducing costs and liquid deposition techniques seem to be an interesting way around vacuum processes.We have developed a simple sol-gel method to fabricated optically clear Distributed Bragg Reflectors (DBR) with silica 1D-photonic crystal upon it made by soft thermal nanoimprint technology. DBRs show a high selective and specular reflection with a low number of layers thanks to the use of materials with a high refractive index contrast: dense titania layers (n=2.10 at λ=600nm) and 50%-macroporous silica layers (n=1,24) which porosity is obtained with a porogen PMMA latex degraded during a single calcination step. These DBRs are easily wavelength tunable by changing the thickness of the layers and they show stable optical properties in harsh environment or after immersion in solvents.Using the RCWA simulation method, we have optimized optical and geometrical parameters of the structure in order to maximize the absorption in a simple photoactive system made of a thin film amorphous silicon layer on glass. We have demonstrated the fabrication of the optimal system with a DBR, a 1D-photonic crystal upon it and a conformal deposited silicon layer. We show that the light trapping structure increases the absorption in a 100nm-thick absorbing layer by almost 70% between 350nm and 800nm. The comparison of the optimized system with other geometries shows the importance of the simulation approach. We went further by integrating a DBR in a real amorphous silicon solar cell. We observed a 5%-increase of the external quantum efficiency thanks to the reflector. This work put forward the sol-gel technology approach applied to photoactive systems.La gestion de la lumière est un élément clé dans le développement de nouveaux matériaux pour l’optique et l’optoélectronique. Dans le domaine énergétique, intégrer des systèmes permettant d’augmenter l’absorption de lumière (photovoltaïque) ou son extraction (technologie LED) conduit à des produits plus efficaces et à moindre coût.Les cellules solaires en couches minces permettent de diminuer la quantité de matériaux actifs utilisés, mais l’absorption de la lumière se trouve limitée par un trajet optique plus court dans le matériau. Une stratégie possible consiste à intégrer des cristaux photoniques pour allonger le trajet des photons de longueurs d’onde spécifiques dans la couche absorbante en les couplant à des modes guidés de celle-ci. De nombreuses recherches sont menées pour fabriquer de tels systèmes tout en limitant les coûts de fabrication et dans ce contexte, la synthèse par voie liquide apparaît comme une alternative intéressante aux méthodes de dépôt sous vide. Au cours de ce travail, nous avons développé une méthode simple par voie sol-gel pour fabriquer des miroirs de Bragg efficaces et robustes (DBR) revêtus des cristaux photoniques obtenus par nanoimpression thermique de couches de silice. Les DBRs présentent une réflexion sélective élevée pour un faible nombre de couches grâce à l’utilisation de matériaux ayant un contraste d’indice particulièrement important : le TiO2 dense (n= 2,10 à λ=600nm) et la silice macroporeuse (n= 1,24) dont la porosité (50%) est obtenue avec la dégradation d’un latex porogène lors d’une unique étape de recuit. Grâce à la flexibilité du procédé, des miroirs réfléchissant dans les Ultra-violets, le visible ou le proche Infra-Rouge peuvent être obtenus.A l’aide de la méthode de simulation RCWA, nous avons optimisé les paramètres optiques et géométriques de la structure pour maximiser l’absorption dans un système photoactif modèle à base de silicium amorphe. Après intégration dans ce système de la structure de piégeage optique optimale, nous avons montré qu’elle permet d’augmenter l’absorption de près de 70% dans 100nm de silicium sur la gamme de longueur d’onde 350 à 800nm. En comparant cette structure à d’autres avec des paramètres géométriques ayant été modulés, nous confirmons l’importance du travail d’optimisation préliminaire par la simulation. Nous avons ensuite appliqué nos résultats dans le cas d’une cellule solaire en couche mince. Nous avons ainsi montré que l’utilisation de nos structures de piégeage optique conduit à une augmentation de rendement quantique externe de l’ordre de 5% pour la structure étudiée. Ces résultats mettent en évidence les grandes possibilités de la technologie sol-gel au service des dispositifs optiquement actifs

    Drop impact dynamics on slippery liquid-infused porous surfaces: influence of oil thickness

    Full text link
    Slippery liquid-infused porous surfaces (SLIPS) are porous nanostructures impregnated with a low surface tension lubricant. They have recently shown great promise in various applications that require non-wettable superhydrophobic surfaces. In this paper, we investigate experimentally the influence of the oil thickness on the wetting properties and drop impact dynamics of new SLIPS. By tuning the thickness of the oil layer deposited through spin-coating, we show that a sufficiently thick layer of oil is necessary to avoid dewetting spots on the porous nanostructure and thus increasing the homogeneity of the liquid distribution. Drop impact on these surfaces is investigated with a particular emphasis on the spreading and rebound dynamics when varying the oil thickness and the Weber number

    Évaluation du coût de distribution des médicaments (analyse prospective au CHU de Grenoble)

    Get PDF
    Étude prospective menée au sein du CHU de Grenoble en Juillet 2012 afin de connaitre le coût de distribution de chaque ligne délivrée aux services selon leurs besoins et le type de spécialités pharmaceutiques réclamées. Cette étude a pour but, de mieux comprendre et appréhender les dépenses tout en valorisant l acte pharmaceutique et améliorer le pilotage des dépenses en respectant les contraintes budgétaires.A prospective study carried on in the University Hospital of Grenoble in July 2012 in order to assess the costs of distribution of each line of drugs delivered to the hospital services according to their needs and the type of pharmaceutical specialties asked for. This study is intended to enhance the understanding of the costs while valuing the pharmaceutical act and to improve management of expenses while respecting budgetary constraints.GRENOBLE1-BU Médecine pharm. (385162101) / SudocSudocFranceF

    Blind benchmark predictions of the NACOK air ingress tests using the CFD code FLUENT

    Get PDF
    Thesis (S.M.)--Massachusetts Institute of Technology, Dept. of Nuclear Science and Engineering, 2007.Includes bibliographical references (p. 123-126).The JAERI and NACOK experiments examine the combined effects of natural convection during an air ingress event: diffusion, onset of natural circulation, graphite oxidation and multicomponent chemical reactions. MIT has been benchmarking JAERI tests using the FLUENT code for approximately three years [1]. This work demonstrated that the three fundamental physical phenomena of diffusion, natural circulation and then chemical reactions can be effectively modeled using computational fluid dynamics. The latest series of tests conducted at the NACOK facility were two graphite corrosion experiments: The first test consisted of an open chimney configuration heated to 650C with a pebble bed zones of graphite pebbles and graphite reflectors. The second test is a similar test with a cold leg adjacent to the hot channel with an open return duct below the hot channel. Natural circulation, diffusion and graphite corrosion were studied for both tests. Using and adapting previous computational methods, the FLUENT code is used to blind benchmark these experiments. The objective is to assess the adequacy of the modeling method used in this blind bench-marking analysis by comparing these blind test predictions to the actual data and then modify the model to improve predictive capability. Ultimately, the objective is to develop a benchmarked analysis capability that can be used for real reactors calculations, and to improve the understanding of the physical phenomena taking place during an air ingress event. This thesis presents the modeling process of these experiments, the blind model results and the comparison of the blind computed data with experimental data. Sensitivity studies provide a good understanding of the different phenomena occurring during an air ingress event. The blind benchmarking demonstrates the ability of FLUENT to model satisfactorily in full scale the NACOK air ingress experiment. The blind models are then improved to successfully model air ingress events. An important finding of this work is that there is great variability in graphite corrosion data and that good qualification of specific graphite used is vital to predicting the effects of an air ingress event.by Marie-Anne V. Brudieu.S.M

    Goigs de la Mare de DĂ©u del mĂłn: a chor unisonal i acompanyament d'harmonium

    No full text
    2 Qd rc ; Veus: [C]; Intr.: Hr

    Prise en charge des patients sous AVK lors d une chirurgie au cabinet dentaire

    No full text
    Les AVK sont utilisés dans le traitement préventif ou curatif des accidents thromboemboliques artériels ou veineux. L utilisation d AVK est en constante augmentation, la complication principale étant l hémorragie. Le chirurgien dentiste doit tenir compte des recommandations de la SFMBCB pour réaliser des actes chirurgicaux chez ce type de patient et maintenir un état d hypocoagulabilité compatible avec l affection du patient. Il est établi que les chirurgiens dentistes en cabinet ne doivent pas procéder à des modifications du traitement AVK avant un acte chirurgical sans risque hémorragique ou à risque hémorragique modéré, si l INR est stable et inférieur à 3. Le pharmacien joue un rôle primordial dans la prise en charge des patients sous AVK aussi bien au niveau pré-opératoire en réalisant une bonne éducation AVK auprès du patient qu au niveau post-opératoire, en insistant sur la surveillance de l INR et ainsi réduire le risque iatrogènique.GRENOBLE1-BU Médecine pharm. (385162101) / SudocSudocFranceF

    Évaluation d une automatisation de l activité de distribution des médicaments aux unités de soins, à la pharmacie du CHU de Grenoble

    No full text
    Évaluation d un système automatisé de distribution de médicaments vers les unités de soins, au sein d une pharmacie hospitalière équipé d un robot et d un automate. Cette étude a pour objectif d évaluer l impact de la mise en place d un système automatisé et ainsi évaluer le gain de temps préparateurs générés pour le redéployer vers des tâches à plus forte valeur ajoutée. A été utilisé des indicateurs de performances pour la productivité et la qualité de distribution.Evaluation of an automated system in a hospital pharmacy dispensary, with one robot and one automate. This study was necessary to evaluate impact of implementation of automated system and evaluate benefits for pharmacy dispensary and staffs.We used to evalute this implementation some producitvity and quality indicators.GRENOBLE1-BU Médecine pharm. (385162101) / SudocSudocFranceF

    Mise en place et évaluation d une automatisation de l activité de distribution des médicaments aux unités de soins à la pharmacie du CHU de Grenoble

    No full text
    Le CHU, dans une démarche de sécurisation du circuit du médicament, s est équipé d un automate de stockage et de distribution des médicaments. L objectif de ce travail était d évaluer l impact de l automatisation sur l activité de distribution des médicaments. L étude prospective comparative entre 2 sites de distribution avec et sans automate a montré que l automatisation permet une augmentation de la productivité de l activité de distribution des médicaments associée à un gain de temps préparateur. Le nombre d erreurs de distribution par jour est augmenté par l automatisation, mais après analyse approfondie des étapes du processus automatisé, les erreurs sont identifiées au niveau de postes à intervention humaine. Ces erreurs ayant mis en évidence une problématique organisationnelle, des améliorations techniques et d encadrement d équipe autour de l automate ont été envisagées. Ces résultats permettent d envisager un redéploiement du personnel pharmaceutique vers les unités de soins.GRENOBLE1-BU Médecine pharm. (385162101) / SudocSudocFranceF

    MULTAQ® (dronédarone) (enquête de pratique sur la place d un nouvel antiarythmique dans les stratégies thérapeutiques actuelles)

    No full text
    Pensée et développée afin de se positionner comme un antiarythmique possédant un bon profil de tolérance et d utilisation aisée, la dronédarone n est finalement pas le médicament qu il aurait dû être. Depuis sa mise sur le marché, les effets indésirables graves apparus et les nouvelles limites de son utilisation empêchent en effet son usage de façon aussi simple que prévue. Néanmoins, nous avons prouvé au cours de notre enquête que malgré cet état de fait, la dronédarone pouvait trouver son indication chez une part relativement importante de patients traités par amiodarone (13 patients sur 88 vus au cours de l enquête, soit 14,7%). Cela montre que, bien que son utilisation puisse se révéler contraignante et limitée à certains types de patients, la dronédarone pourrait éventuellement être une alternative intéressante aux autres antiarythmiques lorsque ceux-ci sont contre-indiqués ou mal tolérés. Cependant, ce travail ne trouvera pleinement son sens que lorsque le statut du MULTAQ® en tant que spécialité remboursable ou non sera clairement défini par les autorités de santé. De plus, la récente mise sur le marché du médicament peut toujours laisser craindre l apparition de nouveaux effets indésirables inattendus. Dans l expectative, il n est donc pas possible de prévoir l avenir de ce médicament et s il pourra s inscrire de façon pérenne au sein des recommandations comme une alternative sérieuse et maitrisée aux autres antiarythmiques dans le traitement des FA non permanentes.GRENOBLE1-BU Médecine pharm. (385162101) / SudocSudocFranceF
    corecore