42 research outputs found
Scaffold-free, Human Mesenchymal Stem Cell-Based Tissue Engineered Blood Vessels
Tissue-engineered blood vessels (TEBV) can serve as vascular grafts and may also play an important role in the development of organs-on-a-chip. Most TEBV construction involves scaffolding with biomaterials such as collagen gel or electrospun fibrous mesh. Hypothesizing that a scaffold-free TEBV may be advantageous, we constructed a tubular structure (1 mm i.d.) from aligned human mesenchymal cell sheets (hMSC) as the wall and human endothelial progenitor cell (hEPC) coating as the lumen. The burst pressure of the scaffold-free TEBV was above 200 mmHg after three weeks of sequential culture in a rotating wall bioreactor and perfusion at 6.8 dynes/cm2. The interwoven organization of the cell layers and extensive extracellular matrix (ECM) formation of the hMSC-based TEBV resembled that of native blood vessels. The TEBV exhibited flow-mediated vasodilation, vasoconstriction after exposure to 1 μM phenylephrine and released nitric oxide in a manner similar to that of porcine femoral vein. HL-60 cells attached to the TEBV lumen after TNF-α activation to suggest a functional endothelium. This study demonstrates the potential of a hEPC endothelialized hMSC-based TEBV for drug screening
Reduced foreign body response at nitric oxide-releasing subcutaneous implants
The tissue response to nitric oxide (NO)-releasing subcutaneous implants is presented. Model implants were created by coating silicone elastomer with diazeniumdiolate-modified xerogel polymers capable of releasing NO. The host tissue response to such implants was evaluated at 1, 3, and 6 weeks and compared to that of uncoated silicone elastomer blanks and xerogel-coated controls incapable of releasing NO. Delivery of NO (~375 pmol/cm2 of implant surface area) reduced the foreign body collagen capsule (“scar tissue”) thickness by >50% compared to uncoated silicone elastomer after 3 weeks. The chronic inflammatory response at the tissue/implant interface was also reduced by >30% at NO-releasing implants after 3 and 6 weeks. Additionally, CD-31 immunohistochemical staining revealed ~77% more blood vessels in proximity to NO-releasing implants after 1 week compared to controls. These findings suggest that conferring NO release to subcutaneous implants may promote effective device integration into healthy vascularized tissue, diminish foreign body capsule formation, and improve the performance of indwelling medical devices that require constant mass transport of analytes (e.g., implantable sensors)
Recommended from our members
Problems in comprehension of informed consent in rural and peri-urban Mali, West Africa
Background: Clinical trials undertaken by industrialized nations in undeveloped nations pose several critical ethical dilemmas. One key potential problem concerns misunderstandings of the consent process by participants. Though other reports have begun to explore this area, needs remain to identify specific areas of misunderstanding.
Purpose: To identify deficits in comprehension during consent processes in Mali, West Africa.
Methods: After obtaining informed consent for participation for a malaria vaccine trial being conducted in two West African villages, we administered to participants a nine-item questionnaire testing their understanding of information relevant for their consent. After testing their ability to understand a multiple choice format, 78 of 100 subjects were administered the questionnaire in one village and 85 of 100 in the other.
Results: Participants had difficulty comprehending several concepts relevant to informed consent: 90% of respondents did not understand withdrawal criterion, 93% did not understand the existence of study side effects, and 74% did not understand that they were enrolled in an investigation as opposed to receiving therapy. The response rate and percentage of correct answers was generally much higher in the village nearer an urban center than the more rural village. The percent of correct answers exceeded 50% for five questions in the urban village and for only two question in the more rural setting.
Limitations: Potential limitations of this study are relating to translation, cultural differences in the notion of informed consent, staff differences between each village, the proportion who could not understand the survey instrument and the fact that the study explored participants’ understanding of the consent process but did not observe the process itself.
Conclusions: This study illustrates potential areas of miscomprehension in the consent process in a developing country. The degree of miscomprehension found in this study appeared to be more than that found in similar studies conducted in industrialized nations. Despite efforts to obtain truly informed consent, several factors make it more challenging in the developing world. This research highlights the need for more comprehensive studies of consent in developing countries. Such studies may eventually aid investigators in identifying, targeting and addressing specific areas of miscomprehension and thereby improve the informed consent process in the developing world
The effect of nitric oxide surface flux on the foreign body response to subcutaneous implants
Although the release of nitric oxide (NO) from biomaterials has been shown to reduce the foreign body response (FBR), the optimal NO release kinetics and doses remain unknown. Herein, polyurethane-coated wire substrates with varying NO release properties were implanted into porcine subcutaneous tissue for 3, 7, 21 and 42 d. Histological analysis revealed that materials with short NO release durations (i.e., 24 h) were insufficient to reduce the collagen capsule thickness at 3 and 6 weeks, whereas implants with longer release durations (i.e., 3 and 14 d) and greater NO payloads significantly reduced the collagen encapsulation at both 3 and 6 weeks. The acute inflammatory response was mitigated most notably by systems with the longest duration and greatest dose of NO release, supporting the notion that these properties are most critical in circumventing the FBR for subcutaneous biomedical applications (e.g., glucose sensors)
Effectiveness and cost-effectiveness of a group-based pain self-management intervention for patients undergoing total hip replacement: Feasibility study for a randomized controlled trial
Background: Total hip replacement (THR) is a common elective surgical procedure and can be effective for reducing chronic pain. However, waiting times can be considerable. A pain self-management intervention may provide patients with skills to more effectively manage their pain and its impact during their wait for surgery. This study aimed to evaluate the feasibility of conducting a randomized controlled trial to assess the effectiveness and cost-effectiveness of a group-based pain self-management course for patients undergoing THR.Methods: Patients listed for a THR at one orthopedic center were posted a study invitation pack. Participants were randomized to attend a pain self-management course plus standard care or standard care only. The lay-led course was delivered by Arthritis Care and consisted of two half-day sessions prior to surgery and one full-day session after surgery. Participants provided outcome and resource-use data using a diary and postal questionnaires prior to surgery and one month, three months and six months after surgery. Brief telephone interviews were conducted with non-participants to explore barriers to participation.Results: Invitations were sent to 385 eligible patients and 88 patients (23%) consented to participate. Interviews with 57 non-participants revealed the most common reasons for non-participation were views about the course and transport difficulties. Of the 43 patients randomized to the intervention group, 28 attended the pre-operative pain self-management sessions and 11 attended the post-operative sessions. Participant satisfaction with the course was high, and feedback highlighted that patients enjoyed the group format. Retention of participants was acceptable (83% of recruited patients completed follow-up) and questionnaire return rates were high (72% to 93%), with the exception of the pre-operative resource-use diary (35% return rate). Resource-use completion rates allowed for an economic evaluation from the health and social care payer perspective.Conclusions: This study highlights the importance of feasibility work prior to a randomized controlled trial to assess recruitment methods and rates, barriers to participation, logistics of scheduling group-based interventions, acceptability of the intervention and piloting resource use questionnaires to improve data available for economic evaluations. This information is of value to researchers and funders in the design and commissioning of future research.Trial registration: Current Controlled Trials ISRCTN52305381. © 2014 Wylde et al.; licensee BioMed Central Ltd
Magnetic Resonance Imaging of a Tissue/Implanted Device Biointerface Using in Vivo Microdialysis Sampling
Bioluminescence Imaging of Glucose in Tissue Surrounding Polyurethane and Glucose Sensor Implants
BACKGROUND: The bioluminescence technique was used to quantify the local glucose concentration in the tissue surrounding subcutaneously implanted polyurethane material and surrounding glucose sensors. In addition, some implants were coated with a single layer of adipose-derived stromal cells (ASCs) because these cells improve the wound-healing response around biomaterials. METHODS: Control and ASC-coated implants were implanted subcutaneously in rats for 1 or 8 weeks (polyurethane) or for 1 week only (glucose sensors). Tissue biopsies adjacent to the implant were immediately frozen at the time of explant. Cryosections were assayed for glucose concentration profile using the bioluminescence technique. RESULTS: For the polyurethane samples, no significant differences in glucose concentration within 100 ÎĽm of the implant surface were found between bare and ASC-coated implants at 1 or 8 weeks. A glucose concentration gradient was demonstrated around the glucose sensors. For all sensors, the minimum glucose concentration of approximately 4 mM was found at the implant surface and increased with distance from the sensor surface until the glucose concentration peaked at approximately 7 mM at 100 ÎĽm. Then the glucose concentration decreased to 5.5-6.5 mM more than 100 ÎĽmm from the surface. CONCLUSIONS: The ASC attachment to polyurethane and to glucose sensors did not change the glucose profiles in the tissue surrounding the implants. Although most glucose sensors incorporate a diffusion barrier to reduce the gradient of glucose and oxygen in the tissue, it is typically assumed that there is no steep glucose gradient around the sensors. However, a glucose gradient was observed around the sensors. A more complete understanding of glucose transport and concentration gradients around sensors is critical