67 research outputs found
Computation of the electron beam quality factors for the NE2571, NE2571A and NE2581A thimble ionization chambers using PENELOPE
The quality correction factor for electron beams was calculated
for three thimble ionization chambers, namely, NE2571, NE2571A and NE2581A. The
Monte Carlo code PENELOPE was used to estimate the overall correction factor
of these chambers for electron beams with nominal energies
ranging between 6 and 22 MeV, corresponding to a Varian Clinac 2100 C/D. A
Co beam was used as reference quality . Also eight
monoenergetic electron beams reproducing the quality index of the
Clinac beams were considered. The factors were calculated as the
ratio between and . Those obtained for the
NE2571 ionization chamber show a nice agreement with those calculated by Muir
and Rogers with EGSnrc. As it occurred to other ionization chambers analyzed in
previous works, the factors found for the monoenergetic beams
are larger (smaller) than those corresponding to the Clinac beams at low (high)
values, the differences being slightly above . Finally, the
factors obtained in the case of the NE2571A chamber are
systematically ~0.5% below those of its predecessor chamber, the NE2571.Comment: 8 pages, 2 figures, 3 table
Higher order and infinite Trotter-number extrapolations in path integral Monte Carlo
Improvements beyond the primitive approximation in the path integral Monte
Carlo method are explored both in a model problem and in real systems. Two
different strategies are studied: the Richardson extrapolation on top of the
path integral Monte Carlo data and the Takahashi-Imada action. The Richardson
extrapolation, mainly combined with the primitive action, always reduces the
number-of-beads dependence, helps in determining the approach to the dominant
power law behavior, and all without additional computational cost. The
Takahashi-Imada action has been tested in two hard-core interacting quantum
liquids at low temperature. The results obtained show that the fourth-order
behavior near the asymptote is conserved, and that the use of this improved
action reduces the computing time with respect to the primitive approximation.Comment: 19 pages, RevTex, to appear in J. Chem. Phy
EP-1362: Influence of the phantom material on the absorbed-dose energy dependence of the EBT3 radiochromic film
Quantum Monte Carlo Algorithm Based on Two-Body Density Functional Theory for Fermionic Many-Body Systems: Application to 3He
We construct a quantum Monte Carlo algorithm for interacting fermions using
the two-body density as the fundamental quantity. The central idea is mapping
the interacting fermionic system onto an auxiliary system of interacting
bosons. The correction term is approximated using correlated wave functions for
the interacting system, resulting in an effective potential that represents the
nodal surface. We calculate the properties of 3He and find good agreement with
experiment and with other theoretical work. In particular, our results for the
total energy agree well with other calculations where the same approximations
were implemented but the standard quantum Monte Carlo algorithm was usedComment: 4 pages, 3 figures, 1 tabl
Liquid-gas transition of neon in quasi-one-dimensional environments
We characterize the behavior of a system of Ne20 atoms in a pure one-dimensional environment between 12 and 30 K by means of path integral Monte Carlo calculations. This is a reasonable model to describe neon absorbed inside a narrow carbon nanotube. When embedded in a bundle of those tubes, this quasi-one-dimensional system can undergo a liquid-gas phase transition if nanotubes are narrow and close enough.Universidad Pablo de Olavide. Departamento de Sistemas Físicos, Químicos y NaturalesVersión del edito
Neon adsorbed in carbon nanotube bundles
By means of path integral Monte Carlo calculations we were able to estimate the chemical potential of Ne atoms adsorbed in the interstitial channels of a bundle of (10,10) carbon nanotubes. This allows us to estimate the temperature and pressure conditions for Ne adsorption in those channels. We also calculate the conditions for Ne filling of a bundle of (5,5) tubes with their caps removed.Universidad Pablo de Olavide. Departamento de Sistemas Físicos, Químicos y NaturalesVersión del edito
- …