2,238 research outputs found
Ponderomotive light squeezing with atomic cavity optomechanics
Accessing distinctly quantum aspects of the interaction between light and the
position of a mechanical object has been an outstanding challenge to
cavity-optomechanical systems. Only cold-atom implementations of cavity
optomechanics have indicated effects of the quantum fluctuations in the optical
radiation pressure force. Here we use such a system, in which quantum
photon-number fluctuations significantly drive the center of mass of an atomic
ensemble inside a Fabry-Perot cavity. We show that the optomechanical response
both amplifies and ponderomotively squeezes the quantum light field. We also
demonstrate that classical optical fluctuations can be attenuated by 26 dB or
amplified by 20 dB with a weak input pump power of < 40 pW, and characterize
the optomechanical amplifier's frequency-dependent gain and phase response in
both the amplitude and phase-modulation quadratures
Colonization Density of the Upper Respiratory Tract as a Predictor of Pneumonia-Haemophilus influenzae, Moraxella catarrhalis, Staphylococcus aureus, and Pneumocystis jirovecii.
Background.
There is limited information on the association between colonization density of upper respiratory tract colonizers and pathogen-specific pneumonia. We assessed this association for Haemophilus influenzae, Moraxella catarrhalis, Staphylococcus aureus, and Pneumocystis jirovecii. Methods.
In 7 low- and middle-income countries, nasopharyngeal/oropharyngeal swabs from children with severe pneumonia and age-frequency matched community controls were tested using quantitative polymerase chain reaction (PCR). Differences in median colonization density were evaluated using the Wilcoxon rank-sum test. Density cutoffs were determined using receiver operating characteristic curves. Cases with a pathogen identified from lung aspirate culture or PCR, pleural fluid culture or PCR, blood culture, and immunofluorescence for P. jirovecii defined microbiologically confirmed cases for the given pathogens. Results.
Higher densities of H. influenzae were observed in both microbiologically confirmed cases and chest radiograph (CXR)–positive cases compared to controls. Staphylococcus aureus and P. jirovecii had higher densities in CXR-positive cases vs controls. A 5.9 log10 copies/mL density cutoff for H. influenzae yielded 86% sensitivity and 77% specificity for detecting microbiologically confirmed cases; however, densities overlapped between cases and controls and positive predictive values were poor (\u3c3%). Informative density cutoffs were not found for S. aureus and M. catarrhalis, and a lack of confirmed case data limited the cutoff identification for P. jirovecii. Conclusions.
There is evidence for an association between H. influenzaecolonization density and H. influenzae–confirmed pneumonia in children; the association may be particularly informative in epidemiologic studies. Colonization densities of M. catarrhalis, S. aureus, and P. jirovecii are unlikely to be of diagnostic value in clinical settings
Capturing Complete Spatial Context in Satellite Observations of Greenhouse Gases
Scientific consensus from a 2015 pre-Decadal Survey workshop highlighted the essential need for a wide-swath (mapping) low earth orbit (LEO) instrument delivering carbon dioxide (CO_2), methane (CH_4), and carbon monoxide (CO) measurements with global coverage. OCO-2 pioneered space-based CO_2 remote sensing, but lacks the CH_4, CO and mapping capabilities required for an improved understanding of the global carbon cycle. The Carbon Balance Observatory (CARBO) advances key technologies to enable high-performance, cost-effective solutions for a space-based carbon-climate observing system. CARBO is a compact, modular, 15-30° field of view spectrometer that delivers high-precision CO_2, CH_4, CO and solar induced chlorophyll fluorescence (SIF) data with weekly global coverage from LEO. CARBO employs innovative immersion grating technologies to achieve diffraction-limited performance with OCO-like spatial (2x2 km^2) and spectral (λ/Δλ ≈ 20,000) resolution in a package that is >50% smaller, lighter and more cost-effective. CARBO delivers a 25- to 50-fold increase in spatial coverage compared to OCO-2 with no loss of detection sensitivity. Individual CARBO modules weigh < 20 kg, opening diverse new space-based platform opportunities
Protein dynamics with off-lattice Monte Carlo moves
A Monte Carlo method for dynamics simulation of all-atom protein models is
introduced, to reach long times not accessible to conventional molecular
dynamics. The considered degrees of freedom are the dihedrals at
C-atoms. Two Monte Carlo moves are used: single rotations about
torsion axes, and cooperative rotations in windows of amide planes, changing
the conformation globally and locally, respectively. For local moves Jacobians
are used to obtain an unbiased distribution of dihedrals. A molecular dynamics
energy function adapted to the protein model is employed. A polypeptide is
folded into native-like structures by local but not by global moves.Comment: 10 pages, 4 Postscript figures, uses epsf.sty and a4.sty; scheduled
tentatively for Phys.Rev.E issue of 1 March 199
Executive Summary of Propulsion on the Orion Abort Flight-Test Vehicles
The National Aeronautics and Space Administration Orion Flight Test Office was tasked with conducting a series of flight tests in several launch abort scenarios to certify that the Orion Launch Abort System is capable of delivering astronauts aboard the Orion Crew Module to a safe environment, away from a failed booster. The first of this series was the Orion Pad Abort 1 Flight-Test Vehicle, which was successfully flown on May 6, 2010 at the White Sands Missile Range in New Mexico. This report provides a brief overview of the three propulsive subsystems used on the Pad Abort 1 Flight-Test Vehicle. An overview of the propulsive systems originally planned for future flight-test vehicles is also provided, which also includes the cold gas Reaction Control System within the Crew Module, and the Peacekeeper first stage rocket motor encased within the Abort Test Booster aeroshell. Although the Constellation program has been cancelled and the operational role of the Orion spacecraft has significantly evolved, lessons learned from Pad Abort 1 and the other flight-test vehicles could certainly contribute to the vehicle architecture of many future human-rated space launch vehicle
Coarse-grained entropy decrease and phase-space focusing in Hamiltonian dynamics
We analyze the behavior of the coarse-grained entropy for classical probabilities in nonlinear Hamiltonians. We focus on the result that if the trajectory dynamics are integrable, the probability ensemble shows transient increases in the coherence, corresponding to an increase in localization of the ensemble and hence the phasespace density of the ensemble. We discuss the connection of these dynamics to the problem of cooling in atomic ensembles. We show how these dynamics can be understood in terms of the behavior of individual trajectories, allowing us to manipulate ensembles to create “cold” dense final ensembles. We illustrate these results with an analysis of the behavior of particular nonlinear integrable systems, including discussions of the spin-echo effect and the seeming violation of Liouville’s theore
Increased shedding of HU177 correlates with worse prognosis in primary melanoma
<p>Abstract</p> <p>Background</p> <p>Increased levels of cryptic collagen epitope HU177 in the sera of melanoma patients have been shown to be associated with thicker primary melanomas and with the nodular histologic subtype. In this study, we investigate the association between HU177 shedding in the sera and clinical outcome in terms of disease-free survival (DFS) and overall survival (OS).</p> <p>Methods</p> <p>Serum samples from 209 patients with primary melanoma prospectively enrolled in the Interdisciplinary Melanoma Cooperative Group at the New York University Langone Medical Center (mean age = 58, mean thickness = 2.09 mm, stage I = 136, stage II = 41, stage III = 32, median follow-up = 54.9 months) were analyzed for HU177 concentration using a validated ELISA assay. HU177 serum levels at the time of diagnosis were used to divide the study cohort into two groups: low and high HU177. DFS and OS were estimated by Kaplan-Meier survival analysis, and the log-rank test was used to compare DFS and OS between the two HU177 groups. Multivariate Cox proportional hazards regression models were employed to examine the independent effect of HU177 category on DFS and OS.</p> <p>Results</p> <p>HU177 sera concentrations ranged from 0-139.8 ng/ml (mean and median of 6.2 ng/ml and 3.7 ng/ml, respectively). Thirty-eight of the 209 (18%) patients developed recurrences, and 34 of the 209 (16%) patients died during follow-up. Higher HU177 serum level was associated with an increased rate of melanoma recurrence (p = 0.04) and with increasing mortality (p = 0.01). The association with overall survival remained statistically significant after controlling for thickness and histologic subtype in a multivariate model (p = 0.035).</p> <p>Conclusions</p> <p>Increased shedding of HU177 in the serum of primary melanoma patients is associated with poor prognosis. Further studies are warranted to determine the clinical utility of HU177 in risk stratification compared to the current standard of care.</p
Association of Blood Biomarkers With Acute Sport-Related Concussion in Collegiate Athletes: Findings From the NCAA and Department of Defense CARE Consortium
Importance:
There is potential scientific and clinical value in validation of objective biomarkers for sport-related concussion (SRC).
Objective:
To investigate the association of acute-phase blood biomarker levels with SRC in collegiate athletes.
Design, Setting, and Participants:
This multicenter, prospective, case-control study was conducted by the National Collegiate Athletic Association (NCAA) and the US Department of Defense Concussion Assessment, Research, and Education (CARE) Consortium from February 20, 2015, to May 31, 2018, at 6 CARE Advanced Research Core sites. A total of 504 collegiate athletes with concussion, contact sport control athletes, and non-contact sport control athletes completed clinical testing and blood collection at preseason baseline, the acute postinjury period, 24 to 48 hours after injury, the point of reporting being asymptomatic, and 7 days after return to play. Data analysis was conducted from March 1 to November 30, 2019.
Main Outcomes and Measures:
Glial fibrillary acidic protein (GFAP), ubiquitin C-terminal hydrolase-L1 (UCH-L1), neurofilament light chain, and tau were quantified using the Quanterix Simoa multiplex assay. Clinical outcome measures included the Sport Concussion Assessment Tool-Third Edition (SCAT-3) symptom evaluation, Standardized Assessment of Concussion, Balance Error Scoring System, and Brief Symptom Inventory 18.
Results:
A total of 264 athletes with concussion (mean [SD] age, 19.08 [1.24] years; 211 [79.9%] male), 138 contact sport controls (mean [SD] age, 19.03 [1.27] years; 107 [77.5%] male), and 102 non-contact sport controls (mean [SD] age, 19.39 [1.25] years; 82 [80.4%] male) were included in the study. Athletes with concussion had significant elevation in GFAP (mean difference, 0.430 pg/mL; 95% CI, 0.339-0.521 pg/mL; P < .001), UCH-L1 (mean difference, 0.449 pg/mL; 95% CI, 0.167-0.732 pg/mL; P < .001), and tau levels (mean difference, 0.221 pg/mL; 95% CI, 0.046-0.396 pg/mL; P = .004) at the acute postinjury time point compared with preseason baseline. Longitudinally, a significant interaction (group × visit) was found for GFAP (F7,1507.36 = 16.18, P < .001), UCH-L1 (F7,1153.09 = 5.71, P < .001), and tau (F7,1480.55 = 6.81, P < .001); the interaction for neurofilament light chain was not significant (F7,1506.90 = 1.33, P = .23). The area under the curve for the combination of GFAP and UCH-L1 in differentiating athletes with concussion from contact sport controls at the acute postinjury period was 0.71 (95% CI, 0.64-0.78; P < .001); the acute postinjury area under the curve for all 4 biomarkers combined was 0.72 (95% CI, 0.65-0.79; P < .001). Beyond SCAT-3 symptom score, GFAP at the acute postinjury time point was associated with the classification of athletes with concussion from contact controls (β = 12.298; 95% CI, 2.776-54.481; P = .001) and non-contact sport controls (β = 5.438; 95% CI, 1.676-17.645; P = .005). Athletes with concussion with loss of consciousness or posttraumatic amnesia had significantly higher levels of GFAP than athletes with concussion with neither loss of consciousness nor posttraumatic amnesia at the acute postinjury time point (mean difference, 0.583 pg/mL; 95% CI, 0.369-0.797 pg/mL; P < .001).
Conclusions and Relevance:
The results suggest that blood biomarkers can be used as research tools to inform the underlying pathophysiological mechanism of concussion and provide additional support for future studies to optimize and validate biomarkers for potential clinical use in SRC
- …