16 research outputs found

    Breast cancer screening in the Czech Republic: time trends in performance indicators during the first seven years of the organised programme

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The Czech Breast Cancer Screening Programme (CBCSP) was initiated in September 2002 by establishing a network of accredited centres. The aim of this article is to describe progress in the programme quality over time after the inception of the organised programme.</p> <p>Methods</p> <p>The CBCSP is monitored using an information system consisting of three principal components: 1) the national cancer registry, 2) a screening registry collecting data on all screening examinations, further assessments and final diagnoses at accredited programme centres, and 3) administrative databases of healthcare payers. Key performance indicators from the European Guidelines have been adopted for continuous monitoring.</p> <p>Results</p> <p>Breast cancer incidence in the Czech Republic has steadily been increasing, however with a growing proportion of less advanced stages. The mortality rate has recently stabilised. The screening registry includes 2,083,285 records on screening episodes between 2002 and 2008. In 2007-2008, 51% of eligible women aged 45-69 were screened. In 2008, the detection rates were 6.1 and 3.7 per 1,000 women in initial and subsequent screening respectively. Corresponding recall rates are 3.9% and 2.2%, however, it is necessary to pay attention to further assessment performed during the screening visits. Benign to malignant open biopsy ratio was 0.1. Of invasive cases detected in screening, 35.6% was less than 10 mm in diameter. Values of early performance indicators, as measured by both crude and standardized estimates, are generally improving and fulfil desirable targets set by European Guidelines.</p> <p>Conclusions</p> <p>Mammography screening in the Czech Republic underwent successful transformation from opportunistic prevention to an organised programme. Values of early indicators confirm continuous improvement in different aspects of process quality. Further stimulation of participation through invitation system is necessary to exploit the full potential of screening mammography at the population level.</p

    Wall shear stress as measured in vivo: consequences for the design of the arterial system

    Get PDF
    Based upon theory, wall shear stress (WSS), an important determinant of endothelial function and gene expression, has been assumed to be constant along the arterial tree and the same in a particular artery across species. In vivo measurements of WSS, however, have shown that these assumptions are far from valid. In this survey we will discuss the assessment of WSS in the arterial system in vivo and present the results obtained in large arteries and arterioles. In vivo WSS can be estimated from wall shear rate, as derived from non-invasively recorded velocity profiles, and whole blood viscosity in large arteries and plasma viscosity in arterioles, avoiding theoretical assumptions. In large arteries velocity profiles can be recorded by means of a specially designed ultrasound system and in arterioles via optical techniques using fluorescent flow velocity tracers. It is shown that in humans mean WSS is substantially higher in the carotid artery (1.1–1.3 Pa) than in the brachial (0.4–0.5 Pa) and femoral (0.3–0.5 Pa) arteries. Also in animals mean WSS varies substantially along the arterial tree. Mean WSS in arterioles varies between about 1.0 and 5.0 Pa in the various studies and is dependent on the site of measurement in these vessels. Across species mean WSS in a particular artery decreases linearly with body mass, e.g., in the infra-renal aorta from 8.8 Pa in mice to 0.5 Pa in humans. The observation that mean WSS is far from constant along the arterial tree implies that Murray’s cube law on flow-diameter relations cannot be applied to the whole arterial system. Because blood flow velocity is not constant along the arterial tree either, a square law also does not hold. The exponent in the power law likely varies along the arterial system, probably from 2 in large arteries near the heart to 3 in arterioles. The in vivo findings also imply that in in vitro studies no average shear stress value can be taken to study effects on endothelial cells derived from different vascular areas or from the same artery in different species. The cells have to be studied under the shear stress conditions they are exposed to in real life

    Immediate and delayed effects of mammographic screening on breast cancer mortality and incidence in birth cohorts

    No full text
    Item does not contain fulltextBackground:Trend studies investigating the impact of mammographic screening usually display age-specific mortality and incidence rates over time, resulting in an underestimate of the benefit of screening, that is, mortality reduction, and an overestimate of its major harmful effect, that is, overdiagnosis. This study proposes a more appropriate way of analysing trends.Methods:Breast cancer mortality (1950-2009) and incidence data (1975-2009) were obtained from Statistics Netherlands, 'Stg. Medische registratie' and the National Cancer Registry in the Netherlands for women aged 25-85 years. Data were visualised in age-birth cohort and age-period figures.Results:Birth cohorts invited to participate in the mammographic screening programme showed a deflection in the breast cancer mortality rates within the first 5 years after invitation. Thereafter, the mortality rate increased, although less rapidly than in uninvited birth cohorts. Furthermore, invited birth cohorts showed a sharp increase in invasive breast cancer incidence rate during the first 5 years of invitation, followed by a moderate increase during the following screening years and a decline after passing the upper age limit.Conclusion:When applying a trend study to estimate the impact of mammographic screening, we recommend using a birth cohort approach
    corecore