36 research outputs found

    Biomechanical evaluation of immediate stability with rectangular versus cylindrical interbody cages in stabilization of the lumbar spine

    Get PDF
    BACKGROUND: Recent cadaver studies show stability against axial rotation with a cylindrical cage is marginally superior to a rectangular cage. The purpose of this biomechanical study in cadaver spine was to evaluate the stability of a new rectangular titanium cage design, which has teeth similar to the threads of cylindrical cages to engage the endplates. METHODS: Ten motion segments (five L2-3, five L4-5) were tested. From each cadaver spine, one motion segment was fixed with a pair of cylindrical cages (BAK, Sulzer Medica) and the other with paired rectangular cages (Rotafix, Corin Spinal). Each specimen was tested in an unconstrained state, after cage introduction and after additional posterior translaminar screw fixation. The range of motion (ROM) in flexion-extension, lateral bending, and rotation was tested in a materials testing machine, with +/- 5 Nm cyclical load over 10 sec per cycle; data from the third cycle was captured for analysis. RESULTS: ROM in all directions was significantly reduced (p < 0.05) with both types of cages. There was no significant difference in reduction of ROM in flexion-extension (p = 0.6) and rotation (p = 0.92) between the two cage groups, but stability in lateral bending was marginally superior with the rectangular cages (p = 0.11). Additional posterior fixation further reduced the ROM significantly (p < 0.05) in most directions in both cage groups, but did not show any difference between the cage groups. CONCLUSIONS: There was no significant difference in immediate stability in any direction between the threaded cylindrical cage and the new design of the rectangular cage with endplate teeth

    Minimizing Blood Loss in Spine Surgery.

    Get PDF
    Study Design: Broad narrative review. Objective: To review and summarize the current literature on guidelines, outcomes, techniques and indications surrounding multiple modalities of minimizing blood loss in spine surgery. Methods: A thorough review of peer-reviewed literature was performed on the guidelines, outcomes, techniques, and indications for multiple modalities of minimizing blood loss in spine surgery. Results: There is a large body of literature that provides a consensus on guidelines regarding the appropriate timing of discontinuation of anticoagulation, aspirin, nonsteroidal anti-inflammatory drugs (NSAIDs), and herbal supplements prior to surgery. Additionally, there is a more heterogenous discussion the utility of preoperative autologous blood donation facilitated by erythropoietin and iron supplementation for healthy patients slated for procedures with high anticipated blood loss and for whom allogeneic transfusion is likely. Intraoperative maneuvers available to minimize blood loss include positioning and maintaining normothermia. Tranexamic acid (TXA), bipolar sealer electrocautery, and topical hemostatic agents, and hypotensive anesthesia (mean arterial pressure (MAP)Hg) should be strongly considered in cases with larger exposures and higher anticipated blood loss. There is strong level 1 evidence for the use of TXA in spine surgery as it reduces the overall blood loss and transfusion requirements. Conclusion: As the volume and complexity of spinal procedures rise, intraoperative blood loss management has become a pivotal topic of research within the field. There are many tools for minimizing blood loss in patients undergoing spine surgery. The current literature supports combining techniques to use a cost- effective multimodal approach to minimize blood loss in the perioperative period

    Development and validation of a large animal ovine model for implant-associated spine infection using biofilm based inocula

    No full text
    Postoperative implant-associated spine infection remains poorly understood. Currently there is no large animal model using biofilm as initial inocula to study this challenging clinical entity. The purpose of the present study was to develop a sheep model for implant-associated spine infection using clinically relevant biofilm inocula and to assess the in vivo utility of methylene blue (MB) for visualizing infected tissues and guiding debridement. This 28-day study used five adult female Rambouillet sheep, each with two non-contiguous surgical sites– in the lumbar and thoracic regions– comprising randomized positive and negative infection control sites. A standard mini-open approach to the spine was performed to place sterile pedicle screws and Staphylococcus aureus biofilm-covered (positive control), or sterile (negative control) spinal fusion rods. Surgical site bioburden was quantified at the terminal procedure. Negative and positive control sites were stained with MB and staining intensity quantified from photographs. Specimens were analyzed with x-ray, micro-CT and histologically. Inoculation rods contained ∼10.44 log10 colony forming units per rod (CFU/rod). Biofilm inocula persisted on positive-control rod explants with ∼6.16 log10 CFU/rod. There was ∼6.35 log10 CFU/g of tissue in the positive controls versus no identifiable bioburden in the negative controls. Positive controls displayed hallmarks of deep spine infection and osteomyelitis, with robust local tissue response, bone resorption, and demineralization. MB staining was more intense in infected, positive control sites. This work presents an animal-efficient sheep model displaying clinically relevant implant-associated deep spine infection
    corecore