29 research outputs found
Panchromatic Imaging of a Transitional Disk: The Disk of GM Aur in Optical and FUV Scattered Light
We have imaged GM Aur with HST, detected its disk in scattered light at 1400A
and 1650A, and compared these with observations at 3300A, 5550A, 1.1 microns,
and 1.6 microns. The scattered light increases at shorter wavelengths. The
radial surface brightness profile at 3300A shows no evidence of the 24AU radius
cavity that has been previously observed in sub-mm observations. Comparison
with dust grain opacity models indicates the surface of the entire disk is
populated with sub-micron grains. We have compiled an SED from 0.1 microns to 1
mm, and used it to constrain a model of the star+disk system that includes the
sub-mm cavity using the Monte Carlo Radiative Transfer code by Barbara Whitney.
The best-fit model image indicates that the cavity should be detectable in the
F330W bandpass if the cavity has been cleared of both large and small dust
grains, but we do not detect it. The lack of an observed cavity can be
explained by the presence of sub-microns grains interior to the sub-mm cavity
wall. We suggest one explanation for this which could be due to a planet of
mass <9 Jupiter masses interior to 24 AU. A unique cylindrical structure is
detected in the FUV data from the Advanced Camera for Surveys/Solar Blind
Channel. It is aligned along the system semi-minor axis, but does not resemble
an accretion-driven jet. The structure is limb-brightened and extends 190 +/-
35 AU above the disk midplane. The inner radius of the limb-brightening is 40
+/- 10 AU, just beyond the sub-millimeter cavity wall.Comment: 40 pages, 11 figures, 4 tables, accepted to Ap
Recommended from our members
Plutonium measurements by accelerator mass spectrometry at LLNL
Mass spectrometric methods provide sensitive, routine, and cost-effective analyses of long-lived radionuclides. Here the authors report on the status of work at Lawrence Livermore National Laboratory (LLNL) to develop a capability for actinide measurements by accelerator mass spectrometry (AMS) to take advantage of the high potential of AMS for rejection of interferences. This work demonstrates that the LLNL AMS spectrometer is well-suited for providing high sensitivity, robust, high throughput measurements of plutonium concentrations and isotope ratios. Present backgrounds are {approximately}2 x 10{sup 7}atoms per sample for environmental samples prepared using standard alpha spectrometry protocols. Recent measurements of {sup 239+240}Pu and {sup 241}Pu activities and {sup 240}Pu/{sup 239}Pu isotope ratios in IAEA reference materials agree well with IAEA reference values and with alpha spectrometry and recently published ICP-MS results. Ongoing upgrades of the AMS spectrometer are expected to reduce backgrounds below 1 x 10{sup 6} atoms per sample while allowing simplifications of the sample preparation chemistry. These simplifications will lead to lower per-sample costs, higher throughput, faster turn around and, ultimately, to larger and more robust data sets