99 research outputs found

    Basic fibroblast growth factor (bFGF) in rodent testis

    Get PDF
    We have previously described a 30 kDa basic fibroblast growth factor (bFGF)-like protein in rodent testicular homogenates and have shown that pachytene spermatocytes are the sites of predominant immunoreactivity for this bFGF-like protein (Mayerhofer, A., Russell, L.D., Grothe, C., Rudolf, M. and Gratzl, M. (1991) Endocrinology 129, 921–924). We have now addressed the question whether this 30 kDa bFGF-like protein is a large bFGF form and whether it is produced by pachytene spermatocytes. We detected bFGF mRNA in homogenates of isolated mouse spermatocytes (which consisted mainly of pachytene spermatocytes) using S1 nuclease protection assays. As shown by Western blot analyses, the bFGF mRNA in mouse spermatocytes is translated into bFGF of an approximate molecular weight of 30 kDa. Neither bFGF mRNA, nor bFGF itself, was observed in isolated mouse Leydig cells. These results indicate that the immunoreactive bFGF-like protein observed previously in germ cells of the murine testis is identical to bFGF. Thus, germ cells of the testis produce bFGF, which may exert regulatory function in the process of spermatogenesis

    A living cell quartz crystal microbalance biosensor for continuous monitoring of cytotoxic responses of macrophages to single-walled carbon nanotubes

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Numerous engineered nanomaterials (ENMs) exist and new ENMs are being developed. A challenge to nanotoxicology and environmental health and safety is evaluating toxicity of ENMs before they become widely utilized. Cellular assays remain the predominant test platform yet these methods are limited by using discrete time endpoints and reliance on organic dyes, vulnerable to interference from ENMs. Label-free, continuous, rapid response systems with biologically meaningful endpoints are needed. We have developed a device to detect and monitor in real time responses of living cells to ENMs. The device, a living cell quartz crystal microbalance biosensor (QCMB), uses macrophages adherent to a quartz crystal. The communal response of macrophages to treatments is monitored continuously as changes in crystal oscillation frequency (Δf). We report the ability of this QCMB to distinguish benign from toxic exposures and reveal unique kinetic information about cellular responses to varying doses of single-walled carbon nanotubes (SWCNTs).</p> <p>Results</p> <p>We analyzed macrophage responses to additions of Zymosan A, polystyrene beads (PBs) (benign substances) or SWCNT (3-150 μg/ml) in the QCMB over 18 hrs. In parallel, toxicity was monitored over 24/48 hrs using conventional viability assays and histological stains to detect apoptosis. In the QCMB, a stable unchanging oscillation frequency occurred when cells alone, Zymosan A alone, PBs alone or SWCNTs without cells at the highest dose alone were used. With living cells in the QCMB, when Zymosan A, PBs or SWCNTs were added, a significant decrease in frequency occurred from 1-6 hrs. For SWCNTs, this Δf was dose-dependent. From 6-18 hrs, benign substances or low dose SWCNT (3-30 μg/ml) treatments showed a reversal of the decrease of oscillation frequency, returning to or exceeding pre-treatment levels. Cell recovery was confirmed in conventional assays. The lag time to see the Δf reversal in QCMB plots was linearly SWCNT-dose dependent. Lastly, the frequency never reversed at high dose SWCNT (100-150 μg/ml), and apoptosis/necrosis was documented in conventional 24 and 48 hr-assays.</p> <p>Conclusion</p> <p>These data suggest that the new QCMB detects and provides unique information about peak, sub-lethal and toxic exposures of living cells to ENMs before they are detected using conventional cell assays.</p

    A Multiwell Electrochemical Biosensor for Real-Time Monitoring of the Behavioural Changes of Cells in Vitro

    Get PDF
    We report the development of a multiwell biosensor for detecting changes in the electrochemical open circuit potential (OCP) generated by viable human cells in vitro. The instrument features eight culture wells; each containing three gold sensors around a common silver/silver chloride reference electrode, prepared using screen-printed conductive inks. The potential applications of the device were demonstrated by monitoring rheumatoid synovial fibroblasts (RSF) and HepG2 hepatocarcinoma cells in response to chemical and biological treatments. This technology could provide an alternative to conventional end-point assays used in the fields of chemotherapy, toxicology and drug discovery

    Mixed Germ Cell Testicular Cancer with Left Ventricular Metastasis Presenting with Embolic Stroke and Small Bowel Tumor Seeding

    No full text
    Testicular germ cell tumors (GCTs) metastasize in a very predictable fashion involving the retroperitoneal nodes first followed by hematogenous spread to distant organs like lungs, liver, and brain. Metastasis to heart is an extremely rare entity for GCT and fewer than 20 cases have been reported in the literature so far. We have summarized here a unique case of nonseminomatous germ cell tumor (NSGCT) with intracardiac metastasis resulting in systemic macroembolization to liver, spleen, brain, bowel and musculoskeletal tissues. This led to multiple adverse sequelae including ischemic stroke and bowel perforation

    Nephrotic Syndrome Secondary to Proliferative Glomerulonephritis with Monoclonal Immunoglobulin Deposits of Lambda Light Chain

    No full text
    We describe a rare case of a 46-year-old woman with history of refractory nephrotic syndrome and hypertension who presented with worsening proteinuria and kidney function. Work-up for both autoimmune and infectious diseases and hematologic malignancies including multiple myeloma were negative. Kidney biopsy demonstrated glomerular sclerotic change with lambda light chain deposits in the subendothelial space, which is consistent with proliferative glomerulonephritis with monoclonal immunoglobulin deposit (PGNMID). The patient was treated with bortezomib and dexamethasone without clinical improvement and eventually became hemodialysis dependent
    corecore