630 research outputs found

    Therapeutic anticoagulation complications in the elderly: a case report

    Get PDF
    Background: The demographic transition leads to a continuously growing number of elderly patients who receive therapeutic anticoagulation by reason of several comorbidities. Though therapeutic anticoagulation may reduce the number of embolic complications in these patients, major complications such as bleeding complications need to be kept in mind when considering such therapy. However, evidence regarding the choice of anticoagulation agents in chronic kidney disease patients of higher age is limited. In this report, a guideline-based anticoagulation treatment which led to a fulminant atraumatic bleeding complication is discussed. Case presentation: We present the case of an 85-year-old female stage V chronic kidney disease patient who suffered from a diffuse arterial, subcutaneous bleeding in her lower left leg due a therapeutic anticoagulation using low molecular weight heparin (LMWH). Anticoagulation was started in accordance with general recommendations for patients with atrial fibrillation, and the dosage was adapted for the patient's renal function. Nevertheless, the above-mentioned complication occurred, and the bleeding led to a hemorrhagic shock and an acute kidney injury on top of a chronic kidney disease. The hematoma required surgical evacuation and local coagulation in the operating room. In the further course, the patient underwent additional four surgical interventions due to a superinfected skin necrosis, including skin grafting. Furthermore, the patient needed continuous renal replacement therapy, as well as intensive care unit treatment, for a total of 47 days followed by 36 days of geriatric rehabilitation. Afterwards, she was discharged from the hospital to her previous nursing home. Discussion and conclusions: Although therapeutic anticoagulation may sufficiently protect patients at cardiovascular risk, major complications such as bleeding complications may occur at any time. Therefore, physicians need to regularly re-evaluate any prior indication for therapeutic anticoagulation. With this case report, we hope to draw attention to the cohort of geriatric patients and the need for more and well differentiated study settings to preferably prevent any potentially avoidable complications

    Comparing Perioperative Outcome Measures of the Dynamic Hip Screw and the Femoral Neck System

    Get PDF
    Background and Objective: Various fixation devices and surgical techniques are available for the management of proximal femur fractures. Recently, the femoral neck system (FNS) was introduced, and was promoted on the basis of less invasiveness, shorter operating time, and less fluoroscopy time compared to previous systems. The aim of this study was to compare two systems for the internal fixation of femoral neck fractures (FNF), namely the dynamic hip screw (DHS) with an anti-rotation screw (ARS) and an FNS. The outcome measures included operating room time (ORT), dose–area product (DAP), length of stay (LOS), perioperative changes in haemoglobin concentrations, and transfusion rate. Materials and Methods: A retrospective single-centre study was conducted. Patients treated for FNF between 1 January 2020 and 30 September 2021 were included, provided that they had undergone closed reduction and internal fixation. We measured the centrum-collum-diaphyseal (CCD) and the Pauwels angle preoperatively and one week postoperatively. Results: In total, 31 patients (16 females), with a mean age of 62.81 ± 15.05 years, were included. Fracture complexity assessed by the Pauwels and Garden classification did not differ between groups preoperatively. Nonetheless, the ORT (54 ± 26.1 min vs. 91.68 ± 23.96 min, p < 0.01) and DAP (721 ± 270.6 cGycmÂČ vs. 1604 ± 1178 cGycmÂČ, p = 0.03) were significantly lower in the FNS group. The pre- and postoperative CCD and Pauwels angles did not differ statistically between groups. Perioperative haemoglobin concentration changes (–1.77 ± 1.19 g/dl vs. –1.74 ± 1.37 g/dl) and LOS (8 ± 5.27 days vs. 7.35 ± 3.43 days) were not statistically different. Conclusions: In this cohort, the ORT and DAP were almost halved in the patient group treated with FNS. This may confer a reduction in secondary risks related to surgery

    Breakage of intramedullary femoral nailing or femoral plating: how to prevent implant failure

    Get PDF
    Introduction: Intramedullary (IM) fixation is the dominant treatment for pertrochanteric and femoral shaft fractures. In comparison to plate osteosynthesis (PO), IM fixation offers greater biomechanical stability and reduced non-union rates. Due to the minimally invasive nature, IM fixations are less prone to approach-associated complications, such as soft-tissue damage, bleeding or postoperative infection, but they are more prone to fat embolism. A rare but serious complication, however, is implant failure. Thus, the aim of this study was to identify possible risk factors for intramedullary fixation (IMF) and plate osteosynthesis (PO) failure. Materials: and methods We searched our trauma surgery database for implant failure, intramedullary and plate osteosynthesis, after proximal-pertrochanteric, subtrochanteric-or femoral shaft fractures between 2011 and 2019. Implant failures in both the IMF and PO groups were included. Demographic data, fracture type, quality of reduction, duration between initial implantation and nail or plate failure, the use of cerclages, intraoperative microbiological samples, sonication, and, if available, histology were collected. Results: A total of 24 femoral implant failures were identified: 11 IMFs and 13 POs. The average age of patients in the IM group was 68.2 +/- 13.5 years and in the PO group was 65.6 +/- 15.0 years, with men being affected in 63.6% and 39.5% of cases, respectively. A proximal femoral nail (PFN) anti-rotation was used in 7 patients, a PFN in one and a gamma nail in two patients. A total of 6 patients required cerclage wires for additional stability. A combined plate and intramedullary fixation was chosen in one patient. Initially, all intramedullary nails were statically locked. Failures were observed 34.1 weeks after the initial surgery on average. Risk factors for implant failure included the application of cerclage wires at the level of the fracture (n = 5, 21%), infection (n = 2, 8%), and the use of an additional sliding screw alongside the femoral neck screw (n = 3, 13%). In all patients, non-union was diagnosed radiographically and clinically after 6 months (n = 24, 100%). In the event of PO failure, the placement of screws within all screw holes, and interprosthetic fixation were recognised as the major causes of failure. Conclusion: Intramedullary or plate osteosynthesis remain safe and reliable procedures in the treatment of proximal femoral fractures (pertrochanteric, subtrochanteric and femoral shaft fractures). Nevertheless, the surgeon needs to be aware of several implant-related limitations causing implant breakage. These may include the application of tension band wiring which can lead to a too rigid fixation, or placement of cerclage wires at the fracture site

    Outcome Analysis of the Use of CeramentÂź in Patients with Chronic Osteomyelitis and Corticomedullary Defects

    Get PDF
    Background: Chronic osteomyelitis (OM) is a progressive but mostly low-grade infection of the bones. The management of this disease is highly challenging for physicians. Despite systematic treatment approaches, recurrence rates are high. Further, functional and patient-reported outcome data are lacking, especially after osseous defects are filled with bioresorbable antibiotic carriers. Objective: To assess functional and patient-reported outcome measures (PROM) following the administration of Cerament (R) G or V due to corticomedullary defects in chronic OM. Methods: We conducted a retrospective study from 2015 to 2020, including all patients who received Cerament (R) for the aforementioned reason. Patients were diagnosed and treated in accordance with globally valid recommendations, and corticomedullary defects were filled with Cerament (R) G or V, depending on the expected germ spectrum. Patients were systematically followed up, and outcome measures were collected during outpatient clinic visits. Results: Twenty patients with Cierny and Mader type III OM were included in this study and followed up for 20.2 +/- 17.2 months (95%CI 12.1-28.3). Ten of these patients needed at least one revision (2.0 +/- 1.3 revisions per patient (95%CI 1.1-2.9) during the study period due to OM persistence or local wound complications. There were no statistically significant differences in functional scores or PROMs between groups. Conclusion: The use of Cerament (R) G and V in chronic OM patients with corticomedullary defects appears to have good functional outcomes and satisfactory PROMs. However, the observed rate of local wound complications and the OM persistence rate may be higher when compared to previously published data

    Transforming the German ICD-10 (ICD-10-GM) into Injury Severity Score (ISS)—Introducing a new method for automated re-coding

    Get PDF
    Background: While potentially timesaving, there is no program to automatically transform diagnosis codes of the ICD-10 German modification (ICD-10-GM) into the injury severity score (ISS). Objective: To develop a mapping method from ICD-10-GM into ICD-10 clinical modification (ICD-10-CM) to calculate the abbreviated injury scale (AIS) and ISS of each patient using the ICDPIC-R and to compare the manually and automatically calculated scores. Methods: Between January 2019 and June 2021, the most severe AIS of each body region and the ISS were manually calculated using medical documentation and radiology reports of all major trauma patients of a German level I trauma centre. The ICD-10-GM codes of these patients were exported from the electronic medical data system SAP, and a Java program was written to transform these into ICD-10-CM codes. Afterwards, the ICDPIC-R was used to automatically generate the most severe AIS of each body region and the ISS. The automatically and manually determined ISS and AIS scores were then tested for equivalence. Results: Statistical analysis revealed that the manually and automatically calculated ISS were significantly equivalent over the entire patient cohort. Further sub-group analysis, however, showed that equivalence could only be demonstrated for patients with an ISS between 16 and 24. Likewise, the highest AIS scores of each body region were not equal in the manually and automatically calculated group. Conclusion: Though achieving mapping results highly comparable to previous mapping methods of ICD-10-CM diagnosis codes, it is not unrestrictedly possible to automatically calculate the AIS and ISS using ICD-10-GM codes

    Quercetin Protects Primary Human Osteoblasts Exposed to Cigarette Smoke through Activation of the Antioxidative Enzymes HO-1 and SOD-1

    Get PDF
    Smokers frequently suffer from impaired fracture healing often due to poor bone quality and stability. Cigarette smoking harms bone cells and their homeostasis by increased formation of reactive oxygen species (ROS). The aim of this study was to investigate whether Quercetin, a naturally occurring antioxidant, can protect osteoblasts from the toxic effects of smoking. Human osteoblasts exposed to cigarette smoke medium (CSM) rapidly produced ROS and their viability decreased concentration- and time-dependently. Co-, pre- and postincubation with Quercetin dose-dependently improved their viability. Quercetin increased the expression of the anti-oxidative enzymes heme-oxygenase- (HO-) 1 and superoxide-dismutase- (SOD-) 1. Inhibiting HO-1 activity abolished the protective effect of Quercetin. Our results demonstrate that CSM damages human osteoblasts by accumulation of ROS. Quercetin can diminish this damage by scavenging the radicals and by upregulating the expression of HO-1 and SOD-1. Thus, a dietary supplementation with Quercetin could improve bone matter, stability and even fracture healing in smokers

    On the Feasibility of Fan-Out Wafer-Level Packaging of Capacitive Micromachined Ultrasound Transducers (CMUT) by Using Inkjet-Printed Redistribution Layers

    Get PDF
    Fan-out wafer-level packaging (FOWLP) is an interesting platform for Microelectromechanical systems (MEMS) sensor packaging. Employing FOWLP for MEMS sensor packaging has some unique challenges, while some originate merely from the fabrication of redistribution layers (RDL). For instance, it is crucial to protect the delicate structures and fragile membranes during RDL formation. Thus, additive manufacturing (AM) for RDL formation seems to be an auspicious approach, as those challenges are conquered by principle. In this study, by exploiting the benefits of AM, RDLs for fan-out packaging of capacitive micromachined ultrasound transducers (CMUT) were realized via drop-on-demand inkjet printing technology. The long-term reliability of the printed tracks was assessed via temperature cycling tests. The effects of multilayering and implementation of an insulating ramp on the reliability of the conductive tracks were identified. Packaging-induced stresses on CMUT dies were further investigated via laser-Doppler vibrometry (LDV) measurements and the corresponding resonance frequency shift. Conclusively, the bottlenecks of the inkjet-printed RDLs for FOWLP were discussed in detail.EC/H2020/737487/EU/(Ultra)Sound Interfaces and Low Energy iNtegrated SEnsors/SILENS

    Comparative Analysis of Microfluidics Thrombus Formation in Multiple Genetically Modified Mice: Link to Thrombosis and Hemostasis

    Get PDF
    Genetically modified mice are indispensable for establishing the roles of platelets in arterial thrombosis and hemostasis. Microfluidics assays using anticoagulated whole blood are commonly used as integrative proxy tests for platelet function in mice. In the present study, we quantified the changes in collagen-dependent thrombus formation for 38 different strains of (genetically) modified mice, all measured with the same microfluidics chamber. The mice included were deficient in platelet receptors, protein kinases or phosphatases, small GTPases or other signaling or scaffold proteins. By standardized re-analysis of high-resolution microscopic images, detailed information was obtained on altered platelet adhesion, aggregation and/or activation. For a subset of 11 mouse strains, these platelet functions were further evaluated in rhodocytin- and laminin-dependent thrombus formation, thus allowing a comparison of glycoprotein VI (GPVI), C-type lectin-like receptor 2 (CLEC2) and integrin alpha(6)beta(1) pathways. High homogeneity was found between wild-type mice datasets concerning adhesion and aggregation parameters. Quantitative comparison for the 38 modified mouse strains resulted in a matrix visualizing the impact of the respective (genetic) deficiency on thrombus formation with detailed insight into the type and extent of altered thrombus signatures. Network analysis revealed strong clusters of genes involved in GPVI signaling and Ca2+ homeostasis. The majority of mice demonstrating an antithrombotic phenotype in vivo displayed with a larger or smaller reduction in multi-parameter analysis of collagen-dependent thrombus formation in vitro. Remarkably, in only approximately half of the mouse strains that displayed reduced arterial thrombosis in vivo, this was accompanied by impaired hemostasis. This was also reflected by comparing in vitro thrombus formation (by microfluidics) with alterations in in vivo bleeding time. In conclusion, the presently developed multi-parameter analysis of thrombus formation using microfluidics can be used to: (i) determine the severity of platelet abnormalities;(ii) distinguish between altered platelet adhesion, aggregation and activation;and (iii) elucidate both collagen and non-collagen dependent alterations of thrombus formation. This approach may thereby aid in the better understanding and better assessment of genetic variation that affect in vivo arterial thrombosis and hemostasis
    • 

    corecore