9,525 research outputs found

    Incompressible viscous flow near the leading edge of a flat plate admitting slip

    Get PDF
    The shear stress at the leading edge, calculated on basis of the Navier-Stokes equations and the no-slip boundary condition, approaches infinity. However, taking into account the mean free path of the molecules, which implies admitting a certain slip, the shear stress becomes inversely proportional to the square root of the Knudsen number κ if κ→0. κ is defined as the ratio between the mean free path and the viscous length. The new boundary condition modifies the shear stress only within the Knudsen region of which the size is of the order of 3 to 4 times the mean free path.

    Accuracy Characterization of a MEMS Accelerometer for Vibration Monitoring in a Rotating Framework

    Get PDF
    Active and passive vibration control systems are of paramount importance in many engineering applications. If an external load excites a structure’s resonance and the damping is too low, detrimental events, such as crack initiation, growth and, in the worst case, fatigue failure, can be entailed. Damping systems can be commonly found in applications such as industrial machines, vehicles, buildings, turbomachinery blades, and so forth. Active control systems usually achieve higher damping effectiveness than passive ones, but they need a sensor to detect the working conditions that require damping system activation. Recently, the development of such systems in rotating structures has received considerable interest among designers. As a result, the development of vibration monitoring equipment in rotating structures is also a topic of particular interest. In this respect, a reliable, inexpensive and wireless monitoring system is of utmost importance. Typically, optical systems are used to measure vibrations, but they are expensive and require rather complex processing algorithms. In this paper, a wireless system based on a commercial MEMS accelerometer is developed for rotating blade vibration monitoring. The proposed system measurement accuracy was assessed by means of comparison with a reference wired measurement setup based on a mini integrated circuit piezoelectric (ICP) accelerometer adapted for data acquisition in a rotating frame. Both the accelerometers were mounted on the tip of the blade and, in order to test the structure under different conditions, the first four blade resonances were excited by means of piezoelectric actuators, embedded in a novel experimental setup. The frequency and amplitude of acceleration, simultaneously measured by the reference and MEMS sensors, were compared with each other in order to investigate the viability and accuracy of the proposed wireless monitoring system. The rotor angular speed was varied from 0 to 300 rpm, and the data acquisitions were repeated six times for each considered condition. The outcomes reveal that the wireless measurement system may be successfully used for vibration monitoring in rotating blades

    The surface accessibility of α-bungarotoxin monitored by a novel paramagnetic probe

    Get PDF
    The surface accessibility of {alpha}-bungarotoxin has been investigated by using Gd2L7, a newly designed paramagnetic NMR probe. Signal attenuations induced by Gd2L7 on {alpha}-bungarotoxin C{alpha}H peaks of 1H-13C HSQC spectra have been analyzed and compared with the ones previously obtained in the presence of GdDTPA-BMA. In spite of the different molecular size and shape, for the two probes a common pathway of approach to the {alpha}-bungarotoxin surface can be observed with an equally enhanced access of both GdDTPA-BMA and Gd2L7 towards the protein surface side where the binding site is located. Molecular dynamics simulations suggest that protein backbone flexibility and surface hydration contribute to the observed preferential approach of both gadolinium complexes specifically to the part of the {alpha}-bungarotoxin surface which is involved in the interaction with its physiological target, the nicotinic acetylcholine receptor

    Analytical Modeling of a New Compliant Microsystem for Atherectomy Operations

    Get PDF
    This work offers a new alternative tool for atherectomy operations, with the purpose of minimizing the risks for the patients and maximizing the number of clinical cases for which the system can be used, thanks to the possibility of scaling its size down to lumen reduced to a few tenths of mm. The development of this microsystem has presented a certain theoretical work during the kinematic synthesis and the design stages. In the first stage a new multi-loop mechanism with a Stephenson’s kinematic chain (KC) was found and then adopted as the so-called pseudo-rigid body mechanism (PRBM). Analytical modeling was necessary to verify the synthesis requirements. In the second stage, the joint replacement method was applied to the PRBM to obtain a corresponding and equivalent compliant mechanism with lumped compliance. The latter presents two loops and six elastic joints and so the evaluation of the microsystem mechanical advantage (MA) had to be calculated by taking into account the accumulation of elastic energy in the elastic joints. Hence, a new closed form expression of the microsystem MA was found with a method that presents some new aspects in the approach. The results obtained with Finite Element Analysis (FEA) were compared to those obtained with the analytical model. Finally, it is worth noting that a microsystem prototype can be fabricated by using MEMS Technology classical methods, while the microsystem packaging could be a further development for the present investigation

    Agrifood Campaign Planning

    Get PDF
    The challenge was to find ways for the players in an agricultural food supply chain to interact in ways that enable the chain to operate more efficiently. What information do they need to exchange, and what incentives need to be in place between them? What software would help the information exchange and responsive actions to take place? The problem was thought about with the UK sugar beet industry as the working example, but similar considerations, with many differences of detail, are expected to apply in other contexts

    Aggregation induced phosphorescent N-oxyde-2,2′-bipyridine bismuth complexes and polymorphism-dependent emission

    Get PDF
    Unprecedented bismuth complexes, based on the rarely used ditopic ligand N-oxide-2,2′-bipyridine (bp2mo), crystallizing as three polymorphs, α- (1), β- (2) and γ-[BiBr3(bp2mo)2] (3), exhibit phosphorescence with a quantum yield up to 17% for the crystal phase (1), while the complex displays a weak fluorescence in solution. A study of the luminescence properties combined with DFT/TDDFT calculations reveals that the lighting phenomenon originated by aggregation induced phosphorescence correlated with the weak intermolecular interactions present in the different crystal phases

    Bismuth-Based Coordination Polymers with Efficient Aggregation-Induced Phosphorescence and Reversible Mechanochromic Luminescence

    Get PDF
    Two bismuth coordination polymers (CPs), (TBA)[BiBr4(bp4mo)] (TBA=tetrabutylammonium) and [BiBr3(bp4mo)2], which are based on the rarely used simple ditopic ligand N-oxide-4,4′-bipyridine (bp4mo), show mechanochromic luminescence (MCL). High solid-state phosphorescence quantum yields of up to 85 % were determined for (TBA)[BiBr4(bp4mo)] (λem=540 nm). Thorough investigations of the luminescence properties combined with DFT and TDDFT calculations revealed that the emission is due to aggregation-induced phosphorescence (AIP). Upon grinding, both samples became amorphous, and their luminescence changed from yellow to orange and red, respectively. Heating or exposure to water vapor led to the recovery of the initial luminescence. These materials are the first examples of mechanochromic phosphors based on bismuth(III)

    Iron Metabolism in the Tumor Microenvironment-Implications for Anti-Cancer Immune Response

    Get PDF
    New insights into the field of iron metabolism within the tumor microenvironment have been uncovered in recent years. Iron promotes the production of reactive oxygen species, which may either trigger ferroptosis cell death or contribute to malignant transformation. Once transformed, cancer cells divert tumor-infiltrating immune cells to satisfy their iron demand, thus affecting the tumor immunosurveillance. In this review, we highlight how the bioavailability of this metal shapes complex metabolic pathways within the tumor microenvironment and how this affects both tumor-associated macrophages and tumor-infiltrating lymphocytes functions. Furthermore, we discuss the potentials as well as the current clinical controversies surrounding the use of iron metabolism as a target for new anticancer treatments in two opposed conditions: i) the "hot" tumors, which are usually enriched in immune cells infiltration and are extremely rich in iron availability within the microenvironment, and ii) the "cold" tumors, which are often very poor in immune cells, mainly due to immune exclusion

    Morphology, rheological and mechanical properties of isotropic and anisotropic PP/rPET/GnP nanocomposite samples

    Get PDF
    The effect of graphene nanoplatelets (GnPs) on the morphology, rheological, and mechanical properties of isotropic and anisotropic polypropylene (PP)/recycled polyethylene terephthalate (rPET)-based nanocomposite are reported. All the samples were prepared by melt mixing. PP/rPET and PP/rPET/GnP isotropic sheets were prepared by compression molding, whereas the anisotropic fibers were spun using a drawing module of a capillary viscometer. The results obtained showed that the viscosity of the blend is reduced by the presence of GnP due to the lubricating effect of the graphene platelets. However, the Cox–Merz rule is not respected. Compared to the PP/rPET blend, the GnP led to a slight increase in the elastic modulus. However, it causes a slight decrease in elongation at break. Morphological analysis revealed a poor adhesion between the PP and PET phases. Moreover, GnPs distribute around the droplets of the PET phase with a honey-like appearance. Finally, the effect of the orientation on both systems gives rise not only to fibers with higher modulus values, but also with high deformability and a fibrillar morphology of the dispersed PET phase. A fragile-ductile transition driven by the orientation was observed in both systems
    • …
    corecore