31 research outputs found

    Colovesical fistula causing an uncommon reason for failure of computed tomography colonography: a case report

    No full text
    Abstract Introduction Computed tomography colonography, or virtual colonoscopy, is a good alternative to optical colonoscopy. However, suboptimal patient preparation or colon distension may reduce the diagnostic accuracy of this imaging technique. Case presentation We report the case of an 83-year-old Caucasian woman who presented with a five-month history of pneumaturia and fecaluria and an acute episode of macrohematuria, leading to a high clinical suspicion of a colovesical fistula. The fistula was confirmed by standard contrast-enhanced computed tomography. Optical colonoscopy was performed to exclude the presence of an underlying colonic neoplasm. Since optical colonoscopy was incomplete, computed tomography colonography was performed, but also failed due to inadequate colon distension. The insufflated air directly accumulated within the bladder via the large fistula. Conclusions Clinicians should consider colovesical fistula as a potential reason for computed tomography colonography failure.</p

    What is the diagnostic performance of 18-FDG-PET/MR compared to PET/CT for the N- and M- staging of breast cancer?

    No full text
    To compare the diagnostic performance of 18-FDG-PET/MR and PET/CT for the N- and M- staging of breast cancer. Two independent readers blinded to clinical/follow-up data reviewed PET/MR and PET/CT examinations performed for initial or recurrent breast cancer staging in 80 consecutive patients (mean age = 48 ± 12.9 years). The diagnostic confidence for lesions in the contralateral breast, axillary/internal mammary nodes, bones and other distant sites were recorded. Sensitivity, specificity, positive (PPV) and negative predictive values (NPV) were calculated. The standard of reference included pathology and/or follow-up &gt; 12 months. Nine of 80 patients had bone metastases; 13/80 had other distant metastases, 44/80 had axillary, 9/80 had internal mammary and 3/80 had contralateral breast tumours. Inter-reader agreement for lesions was excellent (weighted kappa = 0.833 for PET/CT and 0.823 for PET/MR) with similar reader confidence for the two tests (ICC = 0.875). In the patient-per-patient analysis, sensitivity and specificity of PET/MRI and PET/CT were similar (p &gt; 0.05). In the lesion-per-lesion analysis, the sensitivity of PET/MR and PET/CT for bone metastases, other metastases, axillary and internal mammary nodes, contralateral tumours and all lesions together was 0.924 and 0.6923 (p = 0.0034), 0.923 and 0.923 (p = 1), 0.854 and 0.812 (p = 0.157), 0.9 and 0.9 (p = 1), 1 and 0.25 (p = 0.083), and 0.89 and 0.77 (p = 0.0013) respectively. The corresponding specificity was 0.953 and 1 (p = 0.0081), 1 and 1 (p = 1), 0.893 and 0.92 (p = 0.257), 1 and 1 (p = 1), 0.987 and 0.99 (p = 1) and 0.96 and 0.98 (p = 0.0075) respectively. Reader confidence, inter-reader agreement and diagnostic performance per patient were similar with PET/MR and PET/CT. However, for all lesions together, PET/MR had a superior sensitivity and lower specificity in the lesion-per-lesion analysis. • N and M breast cancer staging performance of PET/MR and PET/CT is similar per patient. • In a lesion-per-lesion analysis PET/MR is more sensitive than PET/CT especially for bone metastasis. • Readers' diagnostic confidence is similar for both tests

    Dual Energy CT (DECT) monochromatic imaging: added value of Adaptive Statistical Iterative Reconstructions (ASIR) in portal venography

    Get PDF
    OBJECTIVE: To investigate the effect of the adaptive statistical iterative reconstructions (ASIR) on image quality in portal venography by dual energy CT (DECT) imaging. MATERIALS AND METHODS: DECT scans of 45 cirrhotic patients obtained in the portal venous phase were analyzed. Monochromatic images at 70keV were reconstructed with the following 4 ASIR percentages: 0%, 30%, 50%, and 70%. The image noise (IN) (standard deviation, SD) of portal vein (PV), the contrast-to-noise-ratio (CNR), and the subjective score for the sharpness of PV boundaries, and the diagnostic acceptability (DA) were obtained. The IN, CNR, and the subjective scores were compared among the four ASIR groups. RESULTS: The IN (in HU) of PV (10.05±3.14, 9.23±3.05, 8.44±2.95 and 7.83±2.90) decreased and CNR values of PV (8.04±3.32, 8.95±3.63, 9.80±4.12 and 10.74±4.73) increased with the increase in ASIR percentage (0%, 30%, 50%, and 70%, respectively), and were statistically different for the 4 ASIR groups (p<0.05). The subjective scores showed that the sharpness of portal vein boundaries (3.13±0.59, 2.82±0.44, 2.73±0.54 and 2.07±0.54) decreased with higher ASIR percentages (p<0.05). The subjective diagnostic acceptability was highest at 30% ASIR (p<0.05). CONCLUSIONS: 30% ASIR addition in DECT portal venography could improve the 70 keV monochromatic image quality

    Computed tomography of the chest with model-based iterative reconstruction using a radiation exposure similar to chest X-ray examination: preliminary observations

    No full text
    The purpose of this study was to assess the diagnostic image quality of ultra-low-dose chest computed tomography (ULD-CT) obtained with a radiation dose comparable to chest radiography and reconstructed with filtered back projection (FBP), adaptive statistical iterative reconstruction (ASIR) and model-based iterative reconstruction (MBIR) in comparison with standard dose diagnostic CT (SDD-CT) or low-dose diagnostic CT (LDD-CT) reconstructed with FBP alone