1,569 research outputs found

    Investigation of paramagnetic saturation in lanthanum manganese nitrate

    Get PDF
    Paramagnetic saturation of lanthanum manganese nitrate, La2Mn3(NO3)12·24H2O, has been investigated at liquid He temperatures in a static as well as a dynamical way. With the aid of the molecular-field theory the Casimir and Du Pré dispersion and absorption curves are adapted explicitly to the phenomenon of saturation. A satisfactory agreement has been observed between theory and experiment

    The relation between VLDL-cholesterol and risk of cardiovascular events in patients with manifest cardiovascular disease

    Get PDF
    INTRODUCTION: Apolipoprotein B containing lipoproteins are atherogenic. There is evidence that with low plasma low density lipoprotein cholesterol (LDL-C) levels residual vascular risk might be caused by triglyceride rich lipoproteins such as very-low density lipoproteins (VLDL), chylomicrons and their remnants. We investigated the relationship between VLDL-cholesterol (VLDL-C) and recurrent major adverse cardiovascular events (MACE), major adverse limb events (MALE) and all-cause mortality in a cohort of patients with cardiovascular disease. METHODS: Prospective cohort study in 8057 patients with cardiovascular disease from the UCC-SMART study. The relation between calculated VLDL-C levels and the occurrence of MACE, MALE and all-cause mortality was analyzed with Cox regression models. RESULTS: Patients mean age was 60 ± 10 years, 74% were male, 4894 (61%) had coronary artery disease, 2445 (30%) stroke, 1425 (18%) peripheral arterial disease and 684 (8%) patients had an abdominal aorta aneurysm at baseline. A total of 1535 MACE, 571 MALE and 1792 deaths were observed during a median follow up of 8.2 years (interquartile range 4.512.2). VLDL-C was not associated with risk of MACE or all-cause mortality. In the highest quartile of VLDL-C the risk was higher for major adverse limb events (MALE) (HR 1.49; 95%CI 1.16-1.93) compared to the lowest quartile, after adjustment for confounders including LDL-C and lipid lowering medication. CONCLUSION: In patients with clinically manifest cardiovascular disease plasma VLDL-C confers an increased risk for MALE, but not for MACE and all-cause mortality, independent of established risk factors including LDL-C and lipid-lowering medication

    Relationship between classic vascular risk factors and cumulative recurrent cardiovascular event burden in patients with clinically manifest vascular disease: Results from the UCC-SMART prospective cohort study

    Get PDF
    Objective The aim of the current study was to assess the relationship between classic cardiovascular risk factors and risk of not only the first recurrent atherosclerotic cardiovascular event, but also the total number of non-fatal and fatal cardiovascular events in patients with recently clinically manifest cardiovascular disease (CVD). Design Prospective cohort study. Setting Tertiary care centre. Participants 7239 patients with a recent first manifestation of CVD from the prospective UCC-SMART (Utrecht Cardiovascular Cohort-Second Manifestations of ARTerial disease) cohort study. Outcome measures Total cardiovascular events, including myocardial infarction, stroke, vascular interventions, major limb events and cardiovascular mortality. Results During a median follow-up of 8.9 years, 1412 patients had one recurrent cardiovascular event, while 1290 patients had two or more recurrent events, with a total of 5457 cardiovascular events during follow-up. The HRs for the first recurrent event and cumulative event burden using Prentice-Williams-Peterson models, respectively, were 1.36 (95% CI 1.25 to 1.48) and 1.26 (95% CI 1.17 to 1.35) for smoking, 1.14 (95% CI 1.11 to 1.18) and 1.09 (95% CI 1.06 to 1.12) for non-high-density lipoprotein (HDL) cholesterol, and 1.05 (95% CI 1.03 to 1.07) and 1.04 (95% CI 1.03 to 1.06) for systolic blood pressure per 10 mm Hg. Conclusions In a cohort of patients with established CVD, systolic blood pressure, non-HDL cholesterol and current smoking are important risk factors for not only the first, but also subsequent recurrent events during follow-up. Recurrent event analysis captures the full cumulative burden of CVD in patients

    A biomechanical model of anther opening reveals the roles of dehydration and secondary thickening

    Get PDF
    Understanding the processes that underlie pollen release is a prime target for controlling fertility to enable selective breeding and the efficient production of hybrid crops. Pollen release requires anther opening, which involves changes in the biomechanical properties of the anther wall. In this research, we develop and use a mathematical model to understand how these biomechanical processes lead to anther opening

    Controls on the fate and speciation of Np(V) during iron (oxyhydr)oxide crystallization

    Get PDF
    The speciation and fate of neptunium as Np(V)O2+ during the crystallization of ferrihydrite to hematite and goethite was explored in a range of systems. Adsorption of NpO2+ to iron(III) (oxyhydr)oxide phases was reversible and, for ferrihydrite, occurred through the formation of mononuclear bidentate surface complexes. By contrast, chemical extractions and X-ray absorption spectroscopy (XAS) analyses showed the incorporation of Np(V) into the structure of hematite during its crystallization from ferrihydrite (pH 10.5). This occurred through direct replacement of octahedrally coordinated Fe(III) by Np(V) in neptunate-like coordination. Subsequent analyses on mixed goethite and hematite crystallization products (pH 9.5 and 11) showed that Np(V) was incorporated during crystallization. Conversely, there was limited evidence for Np(V) incorporation during goethite crystallization at the extreme pH of 13.3. This is likely due to the formation of a Np(V) hydroxide precipitate preventing incorporation into the goethite particles. Overall these data highlight the complex behavior of Np(V) during the crystallization of iron(III) (oxyhydr)oxides, and demonstrate clear evidence for neptunium incorporation into environmentally important mineral phases. This extends our knowledge of the range of geochemical conditions under which there is potential for long-term immobilization of radiotoxic Np in natural and engineered environments

    CONVINCE in the context of existing evidence on haemodiafiltration

    Get PDF
    Haemodiafiltration (HDF) provides a greater removal of larger solutes and protein-bound compounds than conventional high-flux haemodialysis (HD). There are indications that the patients receiving the highest convection volumes of HDF result in improved survival compared with HD. However, the comparative efficacy of HDF versus HD remains unproven. Here we provide a comparative account of the methodology and aims of ‘the comparison of high-dose HDF with high-flux HD’ (CONVINCE) study in the context of the totality of evidence and how this study will contribute to reaching a higher level of certainty regarding the comparative efficacy of HDF versus HD in people with end-stage kidney disease

    Ultrasound settings significantly alter arterial lumen and wall thickness measurements

    Get PDF
    Background. Flow-mediated dilation (FMD) and carotid intima-medial thickness (CIMT), measured by ultrasound, are widely used to test the efficacy of cardioprotective interventions. Although assessment methods vary, automated edge-detecting image analysis software is routinely used to measure changes in FMD and CIMT. We aimed to quantify the effect that commonly adjusted ultrasound settings have on arterial lumen and wall thickness measurements made with CIMT measurement software. Methods. We constructed phantom arteries from a tissue-mimicking agar compound and scanned them in a water bath with a 10 MHz multi-frequency linear-array probe attached to a high-resolution ultrasound machine. B-mode images of the phantoms were recorded with dynamic range (DR) and gain set at five decibel (dB) increments from 40 dB to 60 dB and -10 dB to +10 dB respectively. Lumen diameter and wall-thickness were measured off-line using CIMT measurement software. Results. Lumen measurements: there was a strong linear relationship between DR and gain and measured lumen diameter. For a given gain level, a 5 dB increase in DR reduced the measured lumen diameter by 0.02 ± 0.004 mm (p \u3c 0.001). For a given DR level, a 5 dB increase in gain reduced measured lumen diameter by 0.04 ± 0.004 mm (p \u3c 0.001). A 5 mm increase in distance between the ultrasound probe and the artery reduced measured lumen diameter by 0.04 ± 0.03 mm (p \u3c 0.001). CIMT measurements: For a fixed gain level, a 5 dB increase in DR increased measured wall thickness by 0.003 ± 0.002 mm (p \u3c 0.001). The effects of increasing gain were not consistent and appeared to vary depending on the distance between the artery and the ultrasound probe and the thickness of the artery wall. Conclusion. DR, gain and probe distance significantly alter lumen diameter and CIMT measurements made using image analysis software. When CIMT and FMD are used to test the efficacy of cardioprotective interventions, the DR, gain and probe position used to record baseline scans should be documented and replicated in post-treatment scans in individual trial subjects. If more than one sonographer or imaging centre is used to collect data, the study protocol should document specific DR and gain settings to be used in all subjects

    End-stage kidney disease in patients with clinically manifest vascular disease; incidence and risk factors: results from the UCC-SMART cohort study

    Get PDF
    Background: Patients with cardiovascular disease (CVD) are at increased risk of end-stage kidney disease (ESKD). Insights into the incidence and role of modifiable risk factors for end-stage kidney disease may provide means for prevention in patients with cardiovascular disease. Methods: We included 8402 patients with stable cardiovascular disease. Incidence rates (IRs) for end-stage kidney disease were determined stratified according to vascular disease location. Cox proportional hazard models were used to assess the risk of end-stage kidney disease for the different determinants. Results: Sixty-five events were observed with a median follow-up of 8.6 years. The overall incidence rate of end-stage kidney disease was 0.9/1000 person-years. Patients with polyvascular disease had the highest incidence rate (1.8/1000 person-years). Smoking (Hazard ratio (HR) 1.87; 95% CI 1.10–3.19), type 2 diabetes (HR 1.81; 95% CI 1.05–3.14), higher systolic blood pressure (HR 1.37; 95% CI 1.24–1.52/10 mmHg), lower estimated glomerular filtration rate (eGFR) (HR 2.86; 95% CI 2.44–3.23/10 mL/min/1.73 m ) and higher urine albumin/creatinine ratio (uACR) (HR 1.19; 95% CI 1.15–1.23/10 mg/mmol) were independently associated with elevated risk of end-stage kidney disease. Body mass index (BMI), waist circumference, non-HDL-cholesterol and exercise were not independently associated with risk of end-stage kidney disease. Conclusions: Incidence of end-stage kidney disease in patients with cardiovascular disease varies according to vascular disease location. Several modifiable risk factors for end-stage kidney disease were identified in patients with cardiovascular disease. These findings highlight the potential of risk factor management in patients with manifest cardiovascular disease. Graphic abstract: [Figure not available: see fulltext.].

    Incorporation and retention of 99-Tc(IV) in magnetite under high pH conditions

    Get PDF
    Technetium incorporation into magnetite and its behavior during subsequent oxidation has been investigated at high pH to determine the technetium retention mechanism(s) on formation and oxidative perturbation of magnetite in systems relevant to radioactive waste disposal. Ferrihydrite was exposed to Tc(VII)(aq) containing cement leachates (pH 10.5-13.1), and crystallization of magnetite was induced via addition of Fe(II)aq. A combination of X-ray diffraction (XRD), chemical extraction, and X-ray absorption spectroscopy (XAS) techniques provided direct evidence that Tc(VII) was reduced and incorporated into the magnetite structure. Subsequent air oxidation of the magnetite particles for up to 152 days resulted in only limited remobilization of the incorporated Tc(IV). Analysis of both X-ray absorption near edge structure (XANES) and extended X-ray absorption fine structure (EXAFS) data indicated that the Tc(IV) was predominantly incorporated into the magnetite octahedral site in all systems studied. On reoxidation in air, the incorporated Tc(IV) was recalcitrant to oxidative dissolution with less than 40% remobilization to solution despite significant oxidation of the magnetite to maghemite/goethite: All solid associated Tc remained as Tc(IV). The results of this study provide the first direct evidence for significant Tc(IV) incorporation into the magnetite structure and confirm that magnetite incorporated Tc(IV) is recalcitrant to oxidative dissolution. Immobilization of Tc(VII) by reduction and incorporation into magnetite at high pH and with significant stability upon reoxidation has clear and important implications for limiting technetium migration under conditions where magnetite is formed including in geological disposal of radioactive wastes
    corecore