    Fluorescence spectroscopy for identification of atherosclerotic tissue

    Get PDF
    Objective: Vessel perforation and limited steerability of the laser light are the major limitations of laser angioplasty. To improve steerability fluoresence spectroscopy has been proposed for identification of atherosclerotic plaques. The aim was to investigate this. Methods: Fluorescence spectroscopy with three different excitation wavelengths (325 nm, 380 nm, 450 nm) was tested in an emission range of 400 nm to 600 nm. Intensity ratios at 480/420 nm were determined in different types of blood vessels. Necropsy material from 40 patients (punch biopsies of 4 mm diameter from the coronary and carotid artery as well as from the ascending and descending aorta) was studied spectroscopically. Histological alterations of the vessel wall were assessed by a semiquantitative score (0 to 10 points): (a) normal tissue, 0 to 2 points (mean=0.25; n=38); (b) mild atherosclerotic lesions, 3 to 5 points (mean=3.35; n=39); (c) severe atherosclerotic lesions, ≄ 6 points (mean=6.75; n=43). Results: Best spectroscopic results were obtained with an excitation wavelength of 325 nm. In samples with severe atherosclerotic lesions the fluoresence spectra showed a significant reduction of the emitted wavelength intensities when compared to normal tissue. There was a clear separation of the fluorescence spectra between normal and mild as well as between normal and severe atherosclerotic lesions; normal tissue showed an increased intensity in the range from 420 nm to 540 nm, whereas atherosclerotic lesions had no or only a small peak at 480 nm. There was a significant correlation between the semiquantitative score (n=120) and the fluorescence ratio at 480/420 nm (excitation wavelength 325 nm) with a correlation coefficient of 0.87. The spectroscopic results showed no differences between the samples taken from different types of vessels. Conclusions: Fluorescence spectroscopy allows a reliable identification of normal and atherosclerotic lesions. The close correlation between the emitted light intensity ratio at 480/420 nm and the histological alterations of the vessel wall suggests a relationship between vessel wall fluorescence and the atherosclerotic alterations of the wal

    Fluorescence spectroscopy for identification of atherosclerotic tissue

    Full text link
    Objective: Vessel perforation and limited steerability of the laser light are the major limitations of laser angioplasty. To improve steerability fluoresence spectroscopy has been proposed for identification of atherosclerotic plaques. The aim was to investigate this. Methods: Fluorescence spectroscopy with three different excitation wavelengths (325 nm, 380 nm, 450 nm) was tested in an emission range of 400 nm to 600 nm. Intensity ratios at 480/420 nm were determined in different types of blood vessels. Necropsy material from 40 patients (punch biopsies of 4 mm diameter from the coronary and carotid artery as well as from the ascending and descending aorta) was studied spectroscopically. Histological alterations of the vessel wall were assessed by a semiquantitative score (0 to 10 points): (a) normal tissue, 0 to 2 points (mean=0.25; n=38); (b) mild atherosclerotic lesions, 3 to 5 points (mean=3.35; n=39); (c) severe atherosclerotic lesions, ≄ 6 points (mean=6.75; n=43). Results: Best spectroscopic results were obtained with an excitation wavelength of 325 nm. In samples with severe atherosclerotic lesions the fluoresence spectra showed a significant reduction of the emitted wavelength intensities when compared to normal tissue. There was a clear separation of the fluorescence spectra between normal and mild as well as between normal and severe atherosclerotic lesions; normal tissue showed an increased intensity in the range from 420 nm to 540 nm, whereas atherosclerotic lesions had no or only a small peak at 480 nm. There was a significant correlation between the semiquantitative score (n=120) and the fluorescence ratio at 480/420 nm (excitation wavelength 325 nm) with a correlation coefficient of 0.87. The spectroscopic results showed no differences between the samples taken from different types of vessels. Conclusions: Fluorescence spectroscopy allows a reliable identification of normal and atherosclerotic lesions. The close correlation between the emitted light intensity ratio at 480/420 nm and the histological alterations of the vessel wall suggests a relationship between vessel wall fluorescence and the atherosclerotic alterations of the wal

    Withdrawal-induced delirium associated with a benzodiazepine switch: a case report

    Get PDF
    <p>Abstract</p> <p>Introduction</p> <p>Introduced in the early 1960s, diazepam remains among the most frequently prescribed benzodiazepine-type sedatives and hypnotics. Patients with chronic use of short-acting benzodiazepines are frequently switched to diazepam because the accumulating, long-acting metabolite, N-desmethyl-diazepam, prevents benzodiazepine-associated withdrawal symptoms, which can occur during trough plasma levels of short-acting benzodiazepines. Although mild to moderate withdrawal symptoms are frequently observed during benzodiazepine switching to diazepam, severe medical complications associated with this treatment approach have thus far not been reported.</p> <p>Case presentation</p> <p>A 64-year-old female Caucasian with major depression, alcohol dependence and benzodiazepine dependence was successfully treated for depression and, after lorazepam-assisted alcohol detoxification, was switched from lorazepam to diazepam to facilitate benzodiazepine discontinuation. Subsequent to the benzodiazepine switch, our patient unexpectedly developed an acute delirious state, which quickly remitted after re-administration of lorazepam. A newly diagnosed early form of mixed dementia, combining both vascular and Alzheimer-type lesions, was found as a likely contributing factor for the observed vulnerability to benzodiazepine-induced withdrawal symptoms.</p> <p>Conclusion</p> <p>Chronic use of benzodiazepines is common in the elderly and a switch to diazepam often precedes benzodiazepine discontinuation trials. However, contrary to common clinical practice, benzodiazepine switching to diazepam may require cross-titration with slow tapering of the first benzodiazepine to allow for the build-up of N-desmethyl-diazepam, in order to safely prevent severe withdrawal symptoms. Alternatively, long-term treatment with low doses of benzodiazepines may be considered, especially in elderly patients with chronic use of benzodiazepines and proven vulnerability to benzodiazepine-associated withdrawal symptoms.</p

    Conductive supports for combined AFM and SECM on biological membranes

    No full text
    Four different conductive supports are analysed regarding their suitability for combined atomic force and scanning electrochemical microscopy (AFM-SECM) on biological membranes. Highly oriented pyrolytic graphite (HOPG), MoS 2, template stripped gold, and template stripped platinum are compared as supports for high resolution imaging of reconstituted membrane proteins or native membranes, and as electrodes for transferring electrons from or to a redox molecule. We demonstrate that high resolution topographs of the bacterial outer membrane protein F can be recorded by contact mode AFM on all four supports. Electrochemical feedback experiments with conductive cantilevers that feature nanometre-scale electrodes showed fast re-oxidation of the redox couple Ru(NH3)6 3+/2+ with the two metal supports after prolonged immersion in electrolyte. In contrast, the re-oxidation rates decayed quickly to unpractical levels with HOPG or MoS2 under physiological conditions. On HOPG we observed heterogeneity in the re-oxidation rate of the redox molecules with higher feedback currents at step edges. The latter results demonstrate the capability of conductive cantilevers with small electrodes to measure minor variations in an SECM signal and to relate them to nanometre-scale features in a simultaneously recorded AFM topography. Rapid decay of re-oxidation rate and surface heterogeneity make HOPG or MoS 2 less attractive for combined AFM-SECM experiments on biological membranes than template stripped gold or platinum supports. © IOP Publishing Ltd

    Conductive supports for combined AFM–SECM on biological membranes

    No full text
    Four different conductive supports are analysed regarding their suitability for combined atomic force and scanning electrochemical microscopy (AFM-SECM) on biological membranes. Highly oriented pyrolytic graphite (HOPG), MoS 2, template stripped gold, and template stripped platinum are compared as supports for high resolution imaging of reconstituted membrane proteins or native membranes, and as electrodes for transferring electrons from or to a redox molecule. We demonstrate that high resolution topographs of the bacterial outer membrane protein F can be recorded by contact mode AFM on all four supports. Electrochemical feedback experiments with conductive cantilevers that feature nanometre-scale electrodes showed fast re-oxidation of the redox couple Ru(NH3)6 3+/2+ with the two metal supports after prolonged immersion in electrolyte. In contrast, the re-oxidation rates decayed quickly to unpractical levels with HOPG or MoS2 under physiological conditions. On HOPG we observed heterogeneity in the re-oxidation rate of the redox molecules with higher feedback currents at step edges. The latter results demonstrate the capability of conductive cantilevers with small electrodes to measure minor variations in an SECM signal and to relate them to nanometre-scale features in a simultaneously recorded AFM topography. Rapid decay of re-oxidation rate and surface heterogeneity make HOPG or MoS 2 less attractive for combined AFM-SECM experiments on biological membranes than template stripped gold or platinum supports. © IOP Publishing Ltd

    Not so moral moral responses to media entertainment?

    Get PDF
    The present contribution comments Art Raney's article on the role of morality in emotional reactions to media entertainment. It dwells on Raney's distinction between pleasure-based versus appreciation-based media entertainment. On a normative level, Raney seems to favor appreciation-based media entertainment over pleasure-based entertainment, because he presumes the latter one to result from more automatic, archaic and, overall, less desirable moral activity among users. Recalling and extending Raney's arguments, the present article discuss the ambivalence of seemingly moral judgments of characters, the potential selfishness of users' concern for the fate of the protagonist, and potential biases in the appraisals of justice restoration. However, the present article wrestles with Raney's arguments underlying his critical evaluation of pleasure-based entertainment. While agreeing to most of his arguments about the moral mechanisms underlying pleasure-based entertainment, it departs from his normative position. The present article argues that pleasure-based entertainment may fulfill a psychologically functional role: it may allow people to effectively recreate and to restore exhausted resources